Optimal design method for selective nerve stimulation and its application to electrocutaneous display
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
We have developed a tactile display that uses electric current from the skin surface as a stimulus. Our main objective was to independently stimulate a variety of mechanoreceptors and to generate specific sensations by combining stimuli. The key to this goal is selective nerve stimulation. In this paper, a mathematical framework is build for the general design of the selective stimulation. The geometries of electrodes and nerve fibers are arbitrary, and the waveform of the electric current from each electrode is independently controlled. Furthermore, the problem is formulated by linear or quadratic programming, which provides an optimal solution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Selective activation of small motor axons by quasitrapezoidal current pulses
Fang, Z.-P., & Mortimer, J. T. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.76383 · Cited by 222 · cited 2×
“It is common to any study of electrical stimulation, and, hence, there have been many studies on the subject [4,5,10,11].”
BackgroundResultModeling axon membranes for functional electrical stimulation
Rattay, F., & Aberham, M. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.250575 · Cited by 174 · cited 3×
“It is common to any study of electrical stimulation, and, hence, there have been many studies on the subject [4,5,10,11].”
BackgroundResult
Cited by
Understanding Virtual Reality—Interface, Application, and Design
Sherman, W. R., & Craig, A. B. (2003) · Presence: Teleoperators and Virtual Environments · doi:10.1162/105474603322391668 · Cited by 1,327
Sensory substitution and the human-machine interface
Bach-y-Rita, P., & W. Kercel, S. (2003) · Trends in Cognitive Sciences · doi:10.1016/j.tics.2003.10.013 · Cited by 858
Bhowmick, A., & Hazarika, S. M. (2017) · Journal on Multimodal User Interfaces · doi:10.1007/s12193-016-0235-6 · Cited by 271
Efficiency Analysis of Waveform Shape for Electrical Excitation of Nerve Fibers
Wongsarnpigoon, A., Woock, J. P., & Grill, W. M. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2010.2047610 · Cited by 104
Presentation of Various Tactile Sensations Using Micro-Needle Electrotactile Display
Tezuka, M., Kitamura, N., Tanaka, K., & Miki, N. (2016) · PLOS ONE · doi:10.1371/journal.pone.0148410 · Cited by 31
Metadata
- Authors
- Kajimoto, H., Kawakami, N., & Tachi, S.
- Venue
- Proceedings 10th Symposium on Haptic Interfaces for Virtual Environment and Teleoperator Systems. HAPTICS 2002
- Publisher
- IEEE Comput. Soc
- Published
- 2003-06-25
- Pages
- 303-310
- OpenAlex
- W2127594899
- Cited by
- 39
- References
- 2
- FWCI
- 7.49
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optimal design method for selective nerve stimulation and its application to electrocutaneous display. https://app.cochat.ai/papers/10.1109/haptic.2002.998973
- The paper
- Kajimoto, H., Kawakami, N., & Tachi, S. (2003). Optimal design method for selective nerve stimulation and its application to electrocutaneous display. Proceedings 10th Symposium on Haptic Interfaces for Virtual Environment and Teleoperator Systems. HAPTICS 2002. https://doi.org/10.1109/haptic.2002.998973
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.