A new approach to on-line turn fault detection in AC motors
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Turn fault detection is based on the principal that symmetrical (unfaulted) motors powered by symmetrical multiphase voltage sources will have no negative sequence currents flowing in the leads. A turn-to-turn fault will break that symmetry and give rise to a negative sequence current which may then be used as a measure of fault severity or to initiate protective action such as a circuit breaker trip. A new way of looking at the effects of turn faults has been developed that improves sensitivity and speed while reducing the probability of misdetection, taking into account voltage balance, load or voltage variation and instrument errors. The method has been implemented on a PC and tested, in real time, on a specially prepared small motor. Reliable detection of one shorted turn out of 648 turns per phase (in a Y connected motor) was demonstrated with the fault indicator becoming fully developed in two cycles of line frequency after initiation of the fault.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Analysis of Cage Induction Motors with Stator Winding Faults
Williamson, S., & Mirzoian, K. (1985) · IEEE Transactions on Power Apparatus and Systems · doi:10.1109/tpas.1985.319221 · Cited by 183
Alternatives for assessing the electrical integrity of induction motors
Kohler, J. L., Sottile, J., & Trutt, F. C. (1992) · IEEE Transactions on Industry Applications · doi:10.1109/28.158836 · Cited by 108
Cited by
Condition Monitoring and Fault Diagnosis of Electrical Motors—A Review
Nandi, S., Toliyat, H. A., & Li, X. (2005) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2005.847955 · Cited by 2,382
A Survey of Condition Monitoring and Protection Methods for Medium-Voltage Induction Motors
Zhang, P., Du, Y., Habetler, T. G., & Lu, B. (2011) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2010.2090839 · Cited by 706
Condition monitoring and fault diagnosis of electrical machines-a review
Nandi, S., & Toliyat, H. A. (2003) · Conference Record of the 1999 IEEE Industry Applications Conference. Thirty-Forth IAS Annual Meeting (Cat. No.99CH36370) · doi:10.1109/ias.1999.799956 · Cited by 531
A survey of condition monitoring and protection methods for medium voltage induction motors
Zhang, P., Du, Y., Habetler, T. G., & Lu, B. (2009) · 2009 IEEE Energy Conversion Congress and Exposition · doi:10.1109/ecce.2009.5316083 · Cited by 524
Grubic, S., Aller, J. M., Lu, B., & Habetler, T. G. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2004665 · Cited by 490
Cruz, S. M. A., & Cardoso, A. J. M. (2001) · IEEE Transactions on Industry Applications · doi:10.1109/28.952496 · Cited by 464
Transient model for induction machines with stator winding turn faults
Tallam, R. M., Habetler, T. G., & Harley, R. G. (2002) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2002.1003411 · Cited by 428
Da, Y., Shi, X., & Krishnamurthy, M. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2227808 · Cited by 303
“Negative/zero sequence current [16], [17], negative/zero sequence impedance [18], or negative/zero sequence voltage [19], [20] are utilized as indicators for fault detection.”
BackgroundMethodA Survey of Methods for Detection of Stator-Related Faults in Induction Machines
Tallam, R. M., Lee, S. B., Stone, G. C., Kliman, G. B., Yoo, J., Habetler, T. G., & Harley, R. G. (2007) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2007.900448 · Cited by 301
Self-citationCruz, S. M. A., & Marques Cardoso, A. J. (2002) · Conference Record of the 2000 IEEE Industry Applications Conference. Thirty-Fifth IAS Annual Meeting and World Conference on Industrial Applications of Electrical Energy (Cat. No.00CH37129) · doi:10.1109/ias.2000.881141 · Cited by 258
Lee, S. B., Tallam, R. M., & Habetler, T. G. (2003) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2003.810848 · Cited by 248
Application of AI tools in fault diagnosis of electrical machines and drives-an overview
Awadallah, M. A., & Morcos, M. M. (2003) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2003.811739 · Cited by 220
“[20] observed an”
Induction motor fault diagnosis based on neuropredictors and wavelet signal processing
Kim, K., & Parlos, A. G. (2002) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2002.1011258 · Cited by 212
Closed-loop control impact on the diagnosis of induction motors faults
Bellini, A., Filippetti, F., Franceschini, G., & Tassoni, C. (2000) · IEEE Transactions on Industry Applications · doi:10.1109/28.871280 · Cited by 199
Diagnosis of Stator Inter-Turn Short Circuits in DTC Induction Motor Drives
Cruz, S. M. A., & Cardoso, A. J. M. (2004) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2004.834012 · Cited by 185
Sarikhani, A., & Mohammed, O. A. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2222857 · Cited by 177
Stator winding turn-fault detection for closed-loop induction motor drives
Tallam, R. M., Habetler, T. G., & Harley, R. G. (2003) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2003.811784 · Cited by 163
Nandi, S., & Toliyat, H. A. (2002) · IEEE Transactions on Industry Applications · doi:10.1109/28.980363 · Cited by 160
Cruz, S. M. A., & Cardoso, A. J. M. (2005) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2005.847975 · Cited by 158
Comprehensive Evaluation of Inter-Turn Short Circuit Faults in PMSM Used for Electric Vehicles
Zhao, J., Guan, X., Li, C., Mou, Q., & Chen, Z. (2021) · IEEE Transactions on Intelligent Transportation Systems · doi:10.1109/tits.2020.2987637 · Cited by 101
Da, Y., Shi, X., & Krishnamurthy, M. (2011) · 2011 IEEE Vehicle Power and Propulsion Conference · doi:10.1109/vppc.2011.6043248 · Cited by 96
“Negative/zero current [28], negative/zero impedance [29], or negative/zero voltage [30] are utilized as indicators for fault detection.”
Change‐detection algorithm for short‐circuit fault detection in closed‐loop AC drives
Meinguet, F., Semail, E., Kestelyn, X., Mollet, Y., & Gyselinck, J. (2014) · IET Electric Power Applications · doi:10.1049/iet-epa.2012.0316 · Cited by 34
“To overcome these problems, the following implementation is proposed: - a recording of the values of the fault index in healthy operation is performed (ideally at the drive commissioning and in real operating conditions), as already proposed in [1], [8], [18] and [21]; - a minimum fault magnitude is selected; - the fa…”
Background
Metadata
- Authors
- Kliman, G. B., Premerlani, W. J., Koegl, R. A., & Hoeweler, D.
- Venue
- IAS '96. Conference Record of the 1996 IEEE Industry Applications Conference Thirty-First IAS Annual Meeting
- Publisher
- IEEE
- Published
- 2002-12-23
- Volume
- 1
- Pages
- 687-693
- ISSN
- 0197-2618 (ISSN-L)
- OpenAlex
- W2171592504
- Cited by
- 303
- References
- 2
- FWCI
- 33.41
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.