ARMin - Design of a Novel Arm Rehabilitation Robot
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Task-oriented repetitive movement can improve movement performance in patients with neurological or orthopaedic lesions. The application of robotics can serve to assist, enhance, evaluate, and document neurological and orthopaedic rehabilitation of movements. ARMin is a new robot for arm therapy applicable to the training of activities of daily living in clinics. ARMin has a semi-exoskeleton structure with six degrees of freedom, and is equipped with position and force sensors. The mechanical structure, the actuators and the sensors of the robot are optimized for patient-cooperative control strategies based on impedance and admittance architecture. This paper describes the new robot, the mechanical structure, the control circuit, the sensors and actuators and some safety aspects.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Effects of Intensity of Rehabilitation After Stroke: A Research Synthesis
Kwakkel, G., Wagenaar, R. C., Koelman, T. W., Lankhorst, G. J., & Koetsier, J. C. (1997) · Stroke · doi:10.1161/01.str.28.8.1550 · Cited by 589
A novel approach to stroke rehabilitation: Robot-aided sensorimotor stimulation
Volpe, B. T., Krebs, H. I., Hogan, N., Edelstein, L., Diels, C., & Aisen, M. (2000) · Neurology · doi:10.1212/wnl.54.10.1938 · Cited by 582
Robot-aided neurorehabilitation of the upper extremities
Riener, R., Nef, T., & Colombo, G. (2005) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345116 · Cited by 407 · cited 1×
“Several studies prove that arm therapy has positive effects on the rehabilitation progress of stroke patients (see [1] and [ 2 ], for review).”
BackgroundSelf-citationPatient-driven control of FES-supported standing up: a simulation study
Riener, R., & Fuhr, T. (1998) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.681177 · Cited by 327
Self-citationLanghammer, B., & Stanghelle, J. K. (2000) · Clinical Rehabilitation · doi:10.1191/0269215500cr338oa · Cited by 303
Evidenzbasierte Armrehabilitation
Platz, T. (2003) · Der Nervenarzt · doi:10.1007/s00115-003-1549-7 · Cited by 128
Cited by
Feil-Seifer, D., & Mataric, M. J. (2005) · 9th International Conference on Rehabilitation Robotics, 2005. ICORR 2005. · doi:10.1109/icorr.2005.1501143 · Cited by 972
Prange, G. B., Jannink, M. J. A., Groothuis-Oudshoorn, C. G. M., Hermens, H. J., & IJzerman, M. J. (2006) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2005.04.0076 · Cited by 917
Optimizing Compliant, Model-Based Robotic Assistance to Promote Neurorehabilitation
Wolbrecht, E. T., Chan, V., Reinkensmeyer, D. J., & Bobrow, J. E. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.918389 · Cited by 506
Developments in hardware systems of active upper-limb exoskeleton robots: A review
Gopura, R. A. R. C., Bandara, D. S. V., Kiguchi, K., & Mann, G. K. I. (2016) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2015.10.001 · Cited by 480
Design of a Cable-Driven Arm Exoskeleton (CAREX) for Neural Rehabilitation
Mao, Y., & Agrawal, S. K. (2012) · IEEE Transactions on Robotics · doi:10.1109/tro.2012.2189496 · Cited by 409
Poststroke Upper Extremity Rehabilitation: A Review of Robotic Systems and Clinical Results
Brewer, B. R., McDowell, S. K., & Worthen-Chaudhari, L. C. (2007) · Topics in Stroke Rehabilitation · doi:10.1310/tsr1406-22 · Cited by 301
Safety issues in human-robot interactions
Vasic, M., & Billard, A. (2013) · 2013 IEEE International Conference on Robotics and Automation · doi:10.1109/icra.2013.6630576 · Cited by 268
Design, Implementation and Clinical Tests of a Wire-Based Robot for Neurorehabilitation
Rosati, G., Gallina, P., & Masiero, S. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.908560 · Cited by 267
Advances in upper limb stroke rehabilitation: a technology push
Loureiro, R. C. V., Harwin, W. S., Nagai, K., & Johnson, M. (2011) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-011-0797-0 · Cited by 252
A Haptic Knob for Rehabilitation of Hand Function
Lambercy, O., Dovat, L., Gassert, R., Burdet, E., Teo, C. L., & Milner, T. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903913 · Cited by 196
“[ 16 ], [17]. The BiManuTrack is a commercialized device that can train the latter two movements [18], [19].”
BackgroundARMin - Exoskeleton for Arm Therapy in Stroke Patients
Nef, T., Mihelj, M., Kiefer, G., Perndl, C., Muller, R., & Riener, R. (2007) · 2007 IEEE 10th International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2007.4428408 · Cited by 192
“1-4244-1320-6/07/$25.00 (c)2007 IEEE 72 Proceedings ofthe2007IEEE10thInternational Conference onRehabilitation Robotics, June12- 15 , Noordwijk, TheNetherlands coordination ofarmmovements, isometric muscle strength, active rangeofmotion, andfunctional tasks.”
BackgroundInfluentialSelf-citationLiu, J., Cramer, S. C., & Reinkensmeyer, D. (2006) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-3-20 · Cited by 119
Metadata
- Authors
- Nef, T., & Riener, R.
- Venue
- 9th International Conference on Rehabilitation Robotics, 2005. ICORR 2005.
- Publisher
- IEEE
- Published
- 2005-08-30
- Pages
- 57-60
- OpenAlex
- W2139025014
- Cited by
- 180
- References
- 6
- FWCI
- 27.96
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.