CoChat

An EMG-Position Controlled System for an Active Ankle-Foot Prosthesis: An Initial Experimental Study

Au, S.K., Bonato, P., Herr, H. · 2005 · 9th International Conference on Rehabilitation Robotics, 2005. ICORR 2005.
Cited by 142

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Although below-knee prostheses have been commercially available for some time, today's devices are completely passive, and consequently, their mechanical properties remain fixed with walking speed and terrain. To improve the current performance of below-knee prostheses, we study the feasibility of using the amputee's residual limb EMG signals to control the ankle position of an active ankle-foot prosthesis. We propose two control schemes to predict the amputee's intended ankle position: a neural network approach and a muscle model approach. We test these approaches using EMG data measured from an amputee for several target ankle movement patterns. We find that both controllers demonstrate the ability to predict desired ankle movement patterns qualitatively. In the current implementation, the biomimetic EMG-controller demonstrates a smoother and more natural movement pattern than that demonstrated by the neural network approach, suggesting that a biologically-motivated, model-based approach may offer certain advantages in the control of active ankle prostheses.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/icorr.2005.1501123

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

  • A myosignal-based powered exoskeleton system

    Rosen, J., Brand, M., Fuchs, M. B., & Arcan, M. (2001) · IEEE Transactions on Systems, Man, and Cybernetics - Part A: Systems and Humans · doi:10.1109/3468.925661 · Cited by 437 · cited 1×

    “For these reasons, some researchers have developed EMG-controllers for prostheses and exoskeletons, based on neuromuscular control models of human limbs [13]-[ 15 ].”
    Background

Research works printed but not linked: 16

  1. 10.1016/0021-9290(87)90308-3 · doi:10.1016/0021-9290(87)90308-3
  2. inman, 1981, Human Walking
  3. 10.1109/TBME.1990.1438510 · DOI · Paper page
  4. 10.1109/IEMBS.1996.651851 · doi:10.1109/iembs.1996.651851
  5. 10.1109/ROBOT.1999.770463 · DOI · Paper page
  6. 10.1109/TRA.2003.808873 · DOI · Paper page
  7. kim, 2001, Development of an above knee prosthesis using MR damper, Proceeding of the IEEE International Conference on Robotics and Automation, 3686
  8. wilkenfeld, 2000, Biologically Inspired Auto Adaptive Control of a Knee Prosthesis
  9. flowers, 1978, A microprocessor controlled knee mechanism for A/K prosthesis, Proceeding of 3rd CISM-IFToMM International Symposium Theory and Practice of Robots and Manipulators, 28
  10. 10.1109/70.538982 · DOI · Paper page
  11. 10.1016/j.jbiomech.2004.01.017 · DOI · Paper page
  12. palmer, 2002, Sagittal plane characterization of normal human ankle function across a range of walking gait speeds
  13. ron, 2002, Prosthetics and Orthotics Lower Limb and Spinal
  14. koganezawa, 1987, Control aspects of artificial leg, IFAC Control Aspects Biomed Eng, 71
  15. 10.1109/TAC.1978.1101783 · DOI · Paper page
  16. 10.1016/0021-9290(83)90067-2 · DOI · Paper page

Cited by

See all 142

Metadata

Authors
Au, S. K., Bonato, P., & Herr, H.
Venue
9th International Conference on Rehabilitation Robotics, 2005. ICORR 2005.
Publisher
IEEE
Published
2005-08-30
Pages
375-379
OpenAlex
W2141501778
Cited by
142
References
1
FWCI
11.65
Type
conference paper
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.