Generalized elasticities improve patient-cooperative control of rehabilitation robots
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
In the effort to make rehabilitation robots patient-cooperative, two prerequisites have to be met: One is providing the necessary amount of guidance and safety for the patient. Just as important is transparency, i.e. minimum interaction between robot and human when it is not needed. Recently, we suggested the method of generalized elasticities, which reduce undesired interaction forces due to robot dynamics by shaping optimal conservative force fields to compensate these dynamics. We now show that these conservative force fields can not only be used to minimize undesired interaction, but that they can also support and guide the patient during therapy when needed. Thus, the patient is given maximum freedom within a safe training environment, with the aim to maximize training efficacy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Impedance Control: An Approach to Manipulation: Part I—Theory
Hogan, N. (1985) · Journal of Dynamic Systems, Measurement, and Control · doi:10.1115/1.3140702 · Cited by 3,673
Adaptive representation of dynamics during learning of a motor task
Shadmehr, R., & Mussa-Ivaldi, F. (1994) · The Journal of Neuroscience · doi:10.1523/jneurosci.14-05-03208.1994 · Cited by 2,612
Effects of Augmented Exercise Therapy Time After Stroke: A Meta-Analysis
Kwakkel, G., van Peppen, R., Wagenaar, R. C., Wood Dauphinee, S., Richards, C., Ashburn, A., Miller, K., Lincoln, N., Partridge, C., Wellwood, I., et al. (2004) · Stroke · doi:10.1161/01.str.0000143153.76460.7d · Cited by 1,081 · cited 1×
“To promote effective rehabilitation after brain injury, a k ey element is intensive training [1], [2].”
BackgroundRehabilitation Robotics: Performance-Based Progressive Robot-Assisted Therapy
Krebs, H. I., Palazzolo, J. J., Dipietro, L., Ferraro, M., Krol, J., Rannekleiv, K., Volpe, B. T., & Hogan, N. (2003) · Autonomous Robots · doi:10.1023/a:1024494031121 · Cited by 714
Multicenter Randomized Clinical Trial Evaluating the Effectiveness of the Lokomat in Subacute Stroke
Hidler, J., Nichols, D., Pelliccio, M., Brady, K., Campbell, D. D., Kahn, J. H., & Hornby, T. G. (2009) · Neurorehabilitation and Neural Repair · doi:10.1177/1545968308326632 · Cited by 652 · cited 1×
“However, recent multicenter controlled trials showe d that subacute and chronic stroke patients still profit more from conventional manual physiotherapy than from position controlled gait training with the Lokomat [5], [6].”
BackgroundHornby, T. G., Campbell, D. D., Kahn, J. H., Demott, T., Moore, J. L., & Roth, H. R. (2008) · Stroke · doi:10.1161/strokeaha.107.504779 · Cited by 541 · cited 1×
“However, recent multicenter controlled trials showe d that subacute and chronic stroke patients still profit more from conventional manual physiotherapy than from position controlled gait training with the Lokomat [5], [6].”
BackgroundVeneman, J. F., Ekkelenkamp, R., Kruidhof, R., van der Helm, F. C. T., & van der Kooij, H. (2006) · The International Journal of Robotics Research · doi:10.1177/0278364906063829 · Cited by 428 · cited 1×
“The LOPES gait rehabilitation robot [19] was reported to be more transparent without gravity compensation, due to similar eigenfrequencies of robotic and human legs.”
MethodLearning to move amid uncertainty
Scheidt, R. A., Dingwell, J. B., & Mussa-Ivaldi, F. A. (2001) · Journal of Neurophysiology · doi:10.1152/jn.2001.86.2.971 · Cited by 411
Cited by
Augmented visual, auditory, haptic, and multimodal feedback in motor learning: A review
Sigrist, R., Rauter, G., Riener, R., & Wolf, P. (2013) · Psychonomic Bulletin & Review · doi:10.3758/s13423-012-0333-8 · Cited by 1,416
Self-citationTowards more effective robotic gait training for stroke rehabilitation: a review
Pennycott, A., Wyss, D., Vallery, H., Klamroth-Marganska, V., & Riener, R. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-65 · Cited by 259
Self-citationA tendon-based parallel robot applied to motor learning in sports
Rauter, G., von Zitzewitz, J., Duschau-Wicke, A., Vallery, H., & Riener, R. (2010) · 2010 3rd IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics · doi:10.1109/biorob.2010.5627788 · Cited by 41
Self-citationAssistance or challenge? Filling a gap in user-cooperative control
Rauter, G., Sigrist, R., Marchal-Crespo, L., Vallery, H., Riener, R., & Wolf, P. (2011) · 2011 IEEE/RSJ International Conference on Intelligent Robots and Systems · doi:10.1109/iros.2011.6094832 · Cited by 24
“In brief, the PCEA is based on the generalized elastic path control (GEPC) described in [21], and first presented in [23].”
MethodSelf-citation
Metadata
- Authors
- Vallery, H., Duschau-Wicke, A., & Riener, R.
- Venue
- 2009 IEEE International Conference on Rehabilitation Robotics
- Publisher
- IEEE
- Published
- 2009-06
- Pages
- 535-541
- ISSN
- 1945-7898 (ISSN-L)
- OpenAlex
- W2115482830
- Cited by
- 70
- References
- 8
- FWCI
- 11.13
- Type
- conference paper
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Generalized elasticities improve patient-cooperative control of rehabilitation robots. https://app.cochat.ai/papers/10.1109/icorr.2009.5209595
- The paper
- Vallery, H., Duschau-Wicke, A., & Riener, R. (2009). Generalized elasticities improve patient-cooperative control of rehabilitation robots. 2009 IEEE International Conference on Rehabilitation Robotics. https://doi.org/10.1109/icorr.2009.5209595
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.