Soft robotic glove for hand rehabilitation and task specific training
The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
This paper presents advancements in the design of a portable, soft robotic glove for individuals with functional grasp pathologies. The robotic glove leverages soft material actuator technology to safely distribute forces along the length of the finger and provide active flexion and passive extension. These actuators consist of molded elastomeric bladders with anisotropic fiber reinforcements that produce specific bending, twisting, and extending trajectories upon fluid pressurization. In particular, we present a method for customizing a soft actuator to a wearer's biomechanics and demonstrate in a motion capture system that the ranges of motion (ROM) of the two are nearly equivalent. The active ROM of the glove is further evaluated using the Kapandji test. Lastly, in a case study, we present preliminary results of a patient with very weak hand strength performing a timed Box-and-Block test with and without the soft robotic glove.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Heart Disease and Stroke Statistics—2012 Update: A Report From the American Heart Association
Writing Group Members, Roger, V. L., Go, A. S., Lloyd-Jones, D. M., Benjamin, E. J., Berry, J. D., Borden, W. B., Bravata, D. M., Dai, S., Ford, E. S., et al. (2012) · Circulation · doi:10.1161/cir.0b013e31823ac046 · Cited by 7,333 · cited 2×
“I. INTRODUCTION In the US, there are approximately four million chronic stroke survivors suffering from hemiparesis or similar conditions, over 200,000 spinal cord injury (SCI) survivors living with sustained neurological damage, and an estimated 1 of every 5,600 to 7,700 males have Duchenne/Becker muscular dystrophy…”
BackgroundAdult Norms for the Box and Block Test of Manual Dexterity
Mathiowetz, V., Volland, G., Kashman, N., & Weber, K. (1985) · The American Journal of Occupational Therapy · doi:10.5014/ajot.39.6.386 · Cited by 2,105
Wolf, S. L., Winstein, C. J., Miller, J. P., Taub, E., Uswatte, G., Morris, D., Giuliani, C., Light, K. E., Nichols-Larsen, D., & EXCITE Investigators, F. T. (2006) · JAMA · doi:10.1001/jama.296.17.2095 · Cited by 1,889 · cited 2×
“Clinical studies indicate that hand impaired patients who use robotic assistance when performing intense repetitive movements show significant improvement in hand motor functionality when compared to patients without robotic assistance [3], [5], [7], [8].”
BackgroundSoft robotic glove for combined assistance and at-home rehabilitation
Polygerinos, P., Wang, Z., Galloway, K. C., Wood, R. J., & Walsh, C. J. (2015) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.08.014 · Cited by 1,617
Self-citationIlievski, F., Mazzeo, A. D., Shepherd, R. F., Chen, X., & Whitesides, G. M. (2011) · Angewandte Chemie International Edition · doi:10.1002/anie.201006464 · Cited by 1,381
Soft Robotics: A Perspective—Current Trends and Prospects for the Future
Majidi, C. (2014) · Soft Robotics · doi:10.1089/soro.2013.0001 · Cited by 1,302
A survey on robotic devices for upper limb rehabilitation
Maciejasz, P., Eschweiler, J., Gerlach-Hahn, K., Jansen-Troy, A., & Leonhardt, S. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-3 · Cited by 1,210
Modeling of Soft Fiber-Reinforced Bending Actuators
Polygerinos, P., Wang, Z., Overvelde, J. T. B., Galloway, K. C., Wood, R. J., Bertoldi, K., & Walsh, C. J. (2015) · IEEE Transactions on Robotics · doi:10.1109/tro.2015.2428504 · Cited by 910
Self-citationSpinal Cord Injury Facts and Figures at a Glance
(2013) · The Journal of Spinal Cord Medicine · doi:10.1179/1079026813z.000000000136 · Cited by 895
Ilievski, F., Mazzeo, A. D., Shepherd, R. F., Chen, X., & Whitesides, G. M. (2011) · Angewandte Chemie · doi:10.1002/ange.201006464 · Cited by 665
Cited by
Polygerinos, P., Correll, N., Morin, S. A., Mosadegh, B., Onal, C. D., Petersen, K., Cianchetti, M., Tolley, M. T., & Shepherd, R. F. (2017) · Advanced Engineering Materials · doi:10.1002/adem.201700016 · Cited by 1,063
Self-citationLee, C., Kim, M., Kim, Y. J., Hong, N., Ryu, S., Kim, H. J., & Kim, S. (2017) · International Journal of Control, Automation and Systems · doi:10.1007/s12555-016-0462-3 · Cited by 616
Bio-inspired soft robotics: Material selection, actuation, and design
Coyle, S., Majidi, C., LeDuc, P., & Hsia, K. J. (2018) · Extreme Mechanics Letters · doi:10.1016/j.eml.2018.05.003 · Cited by 400
Yap, H. K., Khin, P. M., Koh, T. H., Sun, Y., Liang, X., Lim, J. H., & Yeow, C.-H. (2017) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2017.2669366 · Cited by 277
Yap, H. K., Lim, J. H., Nasrallah, F., & Yeow, C.-H. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00547 · Cited by 195
“…actuators with variable stiffness 200 5 160 MR-Glove/Yap et al., 2017 Fabric-reinforced actuators 180 5 120 Grip Glove/Maeder-York et al., 2014; Polygerinos et al., 2015a,b,c Fiber-reinforced actuators (Pneumatic or Hydraulic) <500 5 345 Nordina et al., 2016 Fiber-reinforced actuators N.A. 5…”
BackgroundMethodResultInfluentialA Helping Hand: Soft Orthosis with Integrated Optical Strain Sensors and EMG Control
Zhao, H., Jalving, J., Huang, R., Knepper, R., Ruina, A., & Shepherd, R. (2016) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2016.2582216 · Cited by 191
EMG controlled soft robotic glove for assistance during activities of daily living
Polygerinos, P., Galloway, K. C., Sanan, S., Herman, M., & Walsh, C. J. (2015) · 2015 IEEE International Conference on Rehabilitation Robotics (ICORR) · doi:10.1109/icorr.2015.7281175 · Cited by 175
“components [20], such as fluidic pump, valves,”
BackgroundInfluentialSelf-citationDevelopment of a polymer-based tendon-driven wearable robotic hand
Kang, B. B., Lee, H., In, H., Jeong, U., Chung, J., & Cho, K.-J. (2016) · 2016 IEEE International Conference on Robotics and Automation (ICRA) · doi:10.1109/icra.2016.7487562 · Cited by 164
“Conventionally, these robots were designed in three ways: a link-based rigid exoskeleton [2-6], a polymer-based soft exoskeleton using pneumatic actuation [7-8], and a fabric-based soft exoskeleton using a tendon drive [9-11].”
MethodA structured overview of trends and technologies used in dynamic hand orthoses
Bos, R. A., Haarman, C. J. W., Stortelder, T., Nizamis, K., Herder, J. L., Stienen, A. H. A., & Plettenburg, D. H. (2016) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-016-0168-z · Cited by 162
“Polygerinos [19, 331, 332] USA 2013–2015 HdO general therapy/assistance 4 N/A”
BackgroundA Novel Soft Glove for Hand Tremor Suppression: Evaluation of Layer Jamming Actuator Placement
Awantha, W. V. I., Wanasinghe, A. T., Kavindya, A. G. P., Kulasekera, A. L., & Chathuranga, D. S. (2020) · 2020 3rd IEEE International Conference on Soft Robotics (RoboSoft) · doi:10.1109/robosoft48309.2020.9115994 · Cited by 31
Metadata
- Authors
- Polygerinos, P., Galloway, K. C., Savage, E., Herman, M., Donnell, K. O., & Walsh, C. J.
- Venue
- 2015 IEEE International Conference on Robotics and Automation (ICRA)
- Publisher
- IEEE
- Published
- 2015-05
- Pages
- 2913-2919
- ISSN
- 1050-4729 (ISSN-L)
- OpenAlex
- W1527981989
- Cited by
- 239
- References
- 20
- FWCI
- 41.42
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.