Optimized design of medium frequency transformers with high isolation requirements
The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
For future DC electric power systems, high-power DC-DC converters will play a major role as they will substitute today's bulky 50/60Hz transformers. One key component within this DC-DC converters is the medium frequency transformer that provides the isolation level and the step up/down of the different voltage levels. As a consequence, an optimized design methodology that considers this high isolation requirements is needed. This paper presents a step-by-step design for medium frequency transformers with high isolation requirements. Each step in the design is carefully discussed and the required design considerations, such as flux density limits, isolation and thermal management, are explained in detail. The proposed design procedure is applied to a core-type transformer analyzing the outcome of the optimization process.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Effects of eddy currents in transformer windings
Dowell, P. L. (1966) · Proceedings of the Institution of Electrical Engineers · doi:10.1049/piee.1966.0236 · Cited by 1,438 · cited 3×
“The skin and proximity effect factors for a strand conductor are Fst,n and Gst,n respectively and their analytical expressions can be extracted from [24].”
BackgroundMethodInfluentialVenkatachalam, K., Sullivan, C. R., Abdallah, T., & Tacca, H. (2003) · 2002 IEEE Workshop on Computers in Power Electronics, 2002. Proceedings. · doi:10.1109/cipe.2002.1196712 · Cited by 1,145 · cited 1×
“In the present design procedure, the approach described in [20] is implemented and its application is straightforward since only the sinusoidal Steinmetz parameters along with the voltage waveforms are required for the computation.”
MethodCalculation of losses in ferro- and ferrimagnetic materials based on the modified Steinmetz equation
Reinert, J., Brockmeyer, A., & De Doncker, R. W. A. A. (2001) · IEEE Transactions on Industry Applications · doi:10.1109/28.936396 · Cited by 704
Lin, D., Zhou, P., Fu, W. N., Badics, Z., & Cendes, Z. J. (2004) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2004.825025 · Cited by 425 · cited 1×
“1) Core Losses: Considerable effort has been devoted to calculation of core losses under non-sinusoidal excitation [20–22].”
BackgroundCalculation of losses in ferro- and ferrimagnetic materials based on the modified Steinmetz equation
Reinert, J., Brockmeyer, A., & De Doncker, R. W. (2003) · Conference Record of the 1999 IEEE Industry Applications Conference. Thirty-Forth IAS Annual Meeting (Cat. No.99CH36370) · doi:10.1109/ias.1999.806023 · Cited by 409
Optimizing the AC resistance of multilayer transformer windings with arbitrary current waveforms
Hurley, W. G., Gath, E., & Breslin, J. G. (2000) · IEEE Transactions on Power Electronics · doi:10.1109/63.838110 · Cited by 368
Medium frequency topology in railway applications
Steiner, M., & Reinold, H. (2007) · 2007 European Conference on Power Electronics and Applications · doi:10.1109/epe.2007.4417570 · Cited by 249 · cited 1×
“However, an optimized design procedure which can clearly state the optimization limits of the MF transformer for given set of selected materials is not yet studied.”
BackgroundKrismer, F., Biela, J., & Kolar, J. W. (2005) · Fourtieth IAS Annual Meeting. Conference Record of the 2005 Industry Applications Conference, 2005. · doi:10.1109/ias.2005.1518368 · Cited by 247 · cited 1×
“As an example, the voltage and current waveforms considering a Dual Active Bridge (DAB) with triangular modulation [11] are shown in Fig.”
MethodSelf-citationOrtiz, G., Biela, J., Bortis, D., & Kolar, J. W. (2010) · The 2010 International Power Electronics Conference - ECCE ASIA - · doi:10.1109/ipec.2010.5542018 · Cited by 229 · cited 2×
“Thereafter, the design can be extended to other types of transformers as the ones presented in [4], which posses their respective geometric definitions.”
BackgroundSelf-citationAnalytical computation of AC resistance of round and rectangular litz wire windings
Ferreira, J. A. (1992) · IEE Proceedings B Electric Power Applications · doi:10.1049/ip-b.1992.0003 · Cited by 207
Cited by
Power Electronic Traction Transformer—Medium Voltage Prototype
Zhao, C., Dujic, D., Mester, A., Steinke, J. K., Weiss, M., Lewdeni-Schmid, S., Chaudhuri, T., & Stefanutti, P. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2278960 · Cited by 478
“This increase in frequency in combination with high insulation requirements imposed by the application itself has opened a challenging research topic regarding magnetics, resulting in various proposals for the MFT realizations [29]–[33] in terms of the selection of materials, type of cooling media, and means for fulfi…”
BackgroundHybrid ac/dc microgrids—Part I: Review and classification of topologies
Unamuno, E., & Barrena, J. A. (2015) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.07.194 · Cited by 399
Gammeter, C., Krismer, F., & Kolar, J. W. (2016) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2015.2459378 · Cited by 105
Self-citationHuang, P., Mao, C., Wang, D., Wang, L., Duan, Y., Qiu, J., Xu, G., & Cai, H. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2674591 · Cited by 78
“Their applications include power gridconnected converters, traction and offshore wind farm [6]–[8].”
BackgroundMethodInfluentialBahmani, M. A., Thiringer, T., & Ortega, H. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2292593 · Cited by 71
“However, on the other hand it will lead to higher loss density due to enhanced core loss and more importantly enhanced winding loss which make it necessary for researchers and designers to more accurately evaluate these losses in order to properly implement a thermal management scheme [4], [5].”
BackgroundDC transformer for DC/DC connection in HVDC network
Carrizosa, M. J., Benchaib, A., Alou, P., & Damm, G. (2013) · 2013 15th European Conference on Power Electronics and Applications (EPE) · doi:10.1109/epe.2013.6631774 · Cited by 65
Design and optimization of medium frequency, medium voltage transformers
Shuai, P., & Biela, J. (2013) · 2013 15th European Conference on Power Electronics and Applications (EPE) · doi:10.1109/epe.2013.6634423 · Cited by 43
“In [7], different core materials are considered for design and temperature calculation is included in optimization process.”
BackgroundSelf-citationA Three-Phase Isolated Building Block for High-Power Medium-Voltage Grid Applications
Gomez, R. A., Porras, D. A., Oggier, G. G., Balda, J. C., & Zhao, Y. (2024) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2023.3311775 · Cited by 16
“They optimize off-the-shelf magnetic cores, mainly ferrites, to fit the specifications and operating conditions of the application [38], [39], [40], [41], [42], [43], [44].”
Background
Metadata
- Authors
- Ortiz, G., Biela, J., & Kolar, J. W.
- Venue
- IECON 2010 - 36th Annual Conference on IEEE Industrial Electronics Society
- Publisher
- IEEE
- Published
- 2010-11
- Pages
- 631-638
- ISSN
- 1553-572X (ISSN-L)
- OpenAlex
- W2065388820
- Cited by
- 159
- References
- 16
- FWCI
- 5.24
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.