A novel multi-port solid state transformer enabled isolated hybrid microgrid architecture
The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
This paper proposes a multi-port solid state transformer (SST) to integrate a hybrid microgrid with 380 V dc, 48 V dc and 415 V ac sub-grids to the medium voltage distribution network. The system replaces multiple single phase transformers in the conventional SST with one multi-winding transformer thereby reducing the magnetics involved. Moreover, the individual dual active bridges (DAB) in the conventional SST is replaced by Multiple Active Bridge (MAB) configuration which reduces the number of H-bridges. The individual sub-grids are isolated, thus eliminating circulating current flow between them. The control architecture and power management for the system are discussed and verified through simulations using MATLAB Simulink.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Control of Power Converters in AC Microgrids
Rocabert, J., Luna, A., Blaabjerg, F., & Rodríguez, P. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2199334 · Cited by 3,723
Lasseter, R. H. (2003) · 2002 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.02CH37309) · doi:10.1109/pesw.2002.985003 · Cited by 1,997
Power Management Strategies for a Microgrid With Multiple Distributed Generation Units
Katiraei, F., & Iravani, M. R. (2006) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2006.879260 · Cited by 1,578 · cited 1×
“The pioneer research in this field focused on ac microgrids to facilitate DG connection to the conventional ac distribution grid[2], [3].”
BackgroundThe Future Renewable Electric Energy Delivery and Management (FREEDM) System: The Energy Internet
Huang, A. Q., Crow, M. L., Heydt, G. T., Zheng, J. P., & Dale, S. J. (2011) · Proceedings of the IEEE · doi:10.1109/jproc.2010.2081330 · Cited by 1,463 · cited 1×
“Solid state transformers (SST) are seen as a promising replacement for the conventional line frequency distribution transformer(LFT) in the future smart grids[10].”
BackgroundA Hybrid AC/DC Microgrid and Its Coordination Control
Liu, X., Wang, P., & Loh, P. C. (2011) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2011.2116162 · Cited by 1,192 · cited 1×
“So a hybrid microgrid structure which combines ac and dc microgrids[4],[5] with power exchange between them is need of the hour.”
BackgroundAutonomous Operation of Hybrid Microgrid With AC and DC Subgrids
Loh, P. C., Li, D., Chai, Y. K., & Blaabjerg, F. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2214792 · Cited by 727 · cited 1×
“So a hybrid microgrid structure which combines ac and dc microgrids[4],[5] with power exchange between them is need of the hour.”
BackgroundFalcones, S., Ayyanar, R., & Mao, X. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2215965 · Cited by 501 · cited 1×
“A seven level cascaded h-bridge (CHB) is used at the front end in [13], [14], [15].”
MethodMadhusoodhanan, S., Tripathi, A., Patel, D., Mainali, K., Kadavelugu, A., Hazra, S., Bhattacharya, S., & Hatua, K. (2015) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2015.2412096 · Cited by 371 · cited 1×
“In [11], [12], a 15 kV SiC IGBT based three level neutral point clamped (NPC) converter is used as the first stage, a three phase DAB as the second stage and two level VSC as the final stage.”
MethodResearch on voltage and power balance control for cascaded modular solid-state transformer
Shi, J., Gou, W., Yuan, H., Zhao, T., & Huang, A. Q. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2106803 · Cited by 362 · cited 1×
“A seven level cascaded h-bridge (CHB) is used at the front end in [13], [14], [15].”
MethodWang, L., Zhang, D., Wang, Y., Wu, B., & Athab, H. S. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2450756 · Cited by 285
Cited by
Hannan, M. A., Ker, P. J., Lipu, M. S. H., Choi, Z. H., Rahman, M. S. A., Muttaqi, K. M., & Blaabjerg, F. (2020) · IEEE Access · doi:10.1109/access.2020.2967345 · Cited by 339
“Moreover, compared to the LFT, SST is much lighter, more compact, and has higher power density which makes it very suitable for widespread use in power distribution systems [134].”
BackgroundDevelopment of a Medium Voltage, High Power, High Frequency Four-Port Solid State Transformer
Shafei, A. E., Özdemir, Ş., Altın, N., Jean-Pierre, G., & Nasiri, A. (2022) · CES Transactions on Electrical Machines and Systems · doi:10.30941/cestems.2022.00013 · Cited by 42
Monteiro, V., Martins, J. S., Fernandes, J. C. A., & Afonso, J. L. (2021) · Sustainability · doi:10.3390/su13169423 · Cited by 43
A Complete Design of a High Frequency Medium Voltage Multi-Port Transformer
Shafei, A. E., Özdemir, Ş., Altın, N., Jean-Pierre, G., & Nasiri, A. (2019) · International Conference on Renewable Energy Research and Applications (ICRERA) · doi:10.1109/icrera47325.2019.8997088 · Cited by 19
“Few articles and research work have been directed towards this concept [15]-[19].”
BackgroundAuxiliary Power Supply for Input-Series Output-Parallel Medium-Voltage Solid State Transformers
Liu, Y., Liu, X., Gao, F., Liu, D., & Wheeler, P. W. (2023) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3258083 · Cited by 16
Metadata
- Authors
- Nair, A. C., & Fernandes, B. G.
- Affiliations
- Indian Institute of Technology Bombay (IN)
- Venue
- IECON 2017 - 43rd Annual Conference of the IEEE Industrial Electronics Society
- Publisher
- IEEE
- Published
- 2017-10
- Volume
- 2
- Pages
- 651-656
- ISSN
- 1553-572X (ISSN-L)
- OpenAlex
- W2773166534
- Cited by
- 15
- References
- 20
- Citations by year
- 2024: 1 · 2023: 2 · 2022: 1 · 2021: 4 · 2020: 3 · 2019: 3 · 2018: 1
- FWCI
- 2.71
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- Annual Conference of the IEEE Industrial Electronics Society (IECON) (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced DC-DC Converters
- Physical Sciences › Engineering › Control and Systems Engineering › Microgrid Control and Optimization
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Keywords
- solid-state transformer, hybrid microgrid, dual active bridge converter, multi-winding transformer, medium-voltage distribution networks, power management, circulating current elimination
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.