A novel multi-port solid state transformer enabled isolated hybrid microgrid architecture
The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
This paper proposes a multi-port solid state transformer (SST) to integrate a hybrid microgrid with 380 V dc, 48 V dc and 415 V ac sub-grids to the medium voltage distribution network. The system replaces multiple single phase transformers in the conventional SST with one multi-winding transformer thereby reducing the magnetics involved. Moreover, the individual dual active bridges (DAB) in the conventional SST is replaced by Multiple Active Bridge (MAB) configuration which reduces the number of H-bridges. The individual sub-grids are isolated, thus eliminating circulating current flow between them. The control architecture and power management for the system are discussed and verified through simulations using MATLAB Simulink.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Control of Power Converters in AC Microgrids
Rocabert, J., Luna, A., Blaabjerg, F., & Rodríguez, P. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2199334 · Cited by 3,723
Lasseter, R. H. (2003) · 2002 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.02CH37309) · doi:10.1109/pesw.2002.985003 · Cited by 1,997
Power Management Strategies for a Microgrid With Multiple Distributed Generation Units
Katiraei, F., & Iravani, M. R. (2006) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2006.879260 · Cited by 1,578
The Future Renewable Electric Energy Delivery and Management (FREEDM) System: The Energy Internet
Huang, A. Q., Crow, M. L., Heydt, G. T., Zheng, J. P., & Dale, S. J. (2011) · Proceedings of the IEEE · doi:10.1109/jproc.2010.2081330 · Cited by 1,463 · cited 1×
“Solid state transformers (SST) are seen as a promising replacement for the conventional line frequency distribution transformer(LFT) in the future smart grids[10].”
BackgroundA Hybrid AC/DC Microgrid and Its Coordination Control
Liu, X., Wang, P., & Loh, P. C. (2011) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2011.2116162 · Cited by 1,192
Autonomous Operation of Hybrid Microgrid With AC and DC Subgrids
Loh, P. C., Li, D., Chai, Y. K., & Blaabjerg, F. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2214792 · Cited by 727
Falcones, S., Ayyanar, R., & Mao, X. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2215965 · Cited by 501
Madhusoodhanan, S., Tripathi, A., Patel, D., Mainali, K., Kadavelugu, A., Hazra, S., Bhattacharya, S., & Hatua, K. (2015) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2015.2412096 · Cited by 371 · cited 1×
“In [11], [12], a 15 kV SiC IGBT based three level neutral point clamped (NPC) converter is used as the first stage, a three phase DAB as the second stage and two level VSC as the final stage.”
MethodResearch on voltage and power balance control for cascaded modular solid-state transformer
Shi, J., Gou, W., Yuan, H., Zhao, T., & Huang, A. Q. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2106803 · Cited by 362
Wang, L., Zhang, D., Wang, Y., Wu, B., & Athab, H. S. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2450756 · Cited by 285
Optimal voltage level for DC microgrids
Anand, S., & Fernandes, B. G. (2010) · IECON 2010 - 36th Annual Conference on IEEE Industrial Electronics Society · doi:10.1109/iecon.2010.5674947 · Cited by 224
Self-citationXia, Y., Peng, Y., Yang, P., Yu, M., & Wei, W. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2603066 · Cited by 178
An Improved Control Method for Multiple Bidirectional Power Converters in Hybrid AC/DC Microgrid
Xiao, H., Luo, A., Shuai, Z., Jin, G., & Huang, Y. (2015) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2015.2469758 · Cited by 156
Zhao, B., Song, Q., & Liu, W. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2350459 · Cited by 143
Chen, T.-P. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2106102 · Cited by 138
A Transformerless Intelligent Power Substation: A three-phase SST enabled by a 15-kV SiC IGBT
Mainali, K., Tripathi, A., Madhusoodhanan, S., Kadavelugu, A., Patel, D., Hazra, S., Hatua, K., & Bhattacharya, S. (2015) · IEEE Power Electronics Magazine · doi:10.1109/mpel.2015.2449271 · Cited by 122
Quad-Active-Bridge DC–DC Converter as Cross-Link for Medium-Voltage Modular Inverters
Costa, L. F., Buticchi, G., & Liserre, M. (2017) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2016.2633539 · Cited by 118
Townsend, C. D., Summers, T. J., & Betz, R. E. (2012) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2012.6342475 · Cited by 85
Chen, H., & Cheng, P.-T. (2016) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2016.2636812 · Cited by 54
Liao, Y., & Chen, H. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2352597 · Cited by 35
Cited by
Hannan, M. A., Ker, P. J., Lipu, M. S. H., Choi, Z. H., Rahman, M. S. A., Muttaqi, K. M., & Blaabjerg, F. (2020) · IEEE Access · doi:10.1109/access.2020.2967345 · Cited by 339
“Moreover, compared to the LFT, SST is much lighter, more compact, and has higher power density which makes it very suitable for widespread use in power distribution systems [134].”
BackgroundDevelopment of a Medium Voltage, High Power, High Frequency Four-Port Solid State Transformer
Shafei, A. E., Özdemir, Ş., Altın, N., Jean-Pierre, G., & Nasiri, A. (2022) · CES Transactions on Electrical Machines and Systems · doi:10.30941/cestems.2022.00013 · Cited by 42
Monteiro, V., Martins, J. S., Fernandes, J. C. A., & Afonso, J. L. (2021) · Sustainability · doi:10.3390/su13169423 · Cited by 43
A Complete Design of a High Frequency Medium Voltage Multi-Port Transformer
Shafei, A. E., Özdemir, Ş., Altın, N., Jean-Pierre, G., & Nasiri, A. (2019) · International Conference on Renewable Energy Research and Applications (ICRERA) · doi:10.1109/icrera47325.2019.8997088 · Cited by 19
Auxiliary Power Supply for Input-Series Output-Parallel Medium-Voltage Solid State Transformers
Liu, Y., Liu, X., Gao, F., Liu, D., & Wheeler, P. W. (2023) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3258083 · Cited by 16
Metadata
- Authors
- Nair, A. C., & Fernandes, B. G.
- Affiliations
- Indian Institute of Technology Bombay (IN)
- Venue
- IECON 2017 - 43rd Annual Conference of the IEEE Industrial Electronics Society
- Publisher
- IEEE
- Published
- 2017-10
- Volume
- 2
- Pages
- 651-656
- ISSN
- 1553-572X (ISSN-L)
- OpenAlex
- W2773166534
- Cited by
- 15
- References
- 20
- Citations by year
- 2024: 1 · 2023: 2 · 2022: 1 · 2021: 4 · 2020: 3 · 2019: 3 · 2018: 1
- FWCI
- 2.71
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- Annual Conference of the IEEE Industrial Electronics Society (IECON) (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced DC-DC Converters
- Physical Sciences › Engineering › Control and Systems Engineering › Microgrid Control and Optimization
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Keywords
- solid-state transformer, hybrid microgrid, dual active bridge converter, multi-winding transformer, medium-voltage distribution networks, power management, circulating current elimination
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.