CoChat

Precision measurement for microsurgical instrument evaluation

Hotraphinyo, L.F., Riviere, C.N. · 2005 · 2001 Conference Proceedings of the 23rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society

The DOI matches its Crossref record, with a small difference in title or year; 9 of the 9 references it cites were found in a registry or an index.

Abstract

An accurate three-dimensional optical sensing system to track the tip of a microsurgical instrument has been developed for laboratory use. The system is useful for evaluation of microsurgical instrument designs and devices for accuracy enhancement (both robotic devices and active hand-held instrument), as well as for assessment and training of microsurgeons. It can also be used as a high-precision input interface to micro-surgical simulators. Tracking is done by illuminating the workspace at an infrared wavelength and using optical sensors to find the position of a small reflective ball at the instrument tip. The RMS noise per coordinate is presently 1 micron. Sample results are presented.

Overview

Integrity signals

Registry

Crossref · 10.1109/iembs.2001.1019573

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 9 references

Research works printed but not linked: 2

  1. schenker, 1995, Development of a telemanipulator for dexterity enhanced microsurgery, Proc 2nd Intl Symp Med Robot Comput Assist Surg, 81
  2. humayun, 1994, The objective analysis of vitreoretinal surgical instruments, Investigative Ophthalmol Vis Sci, 35, 1261

Cited by

See all 28

Metadata

Authors
Hotraphinyo, L. F., & Riviere, C. N.
Affiliations
Carnegie Mellon University (US)
Venue
2001 Conference Proceedings of the 23rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society
Publisher
IEEE
Published
2005-08-25
Volume
4
Pages
3454-3457
ISSN
2375-7477 (ISSN-L)
OpenAlex
W2097521429
Cited by
28
References
9
Citations by year
2021: 1 · 2018: 1 · 2012: 1
FWCI
4.16
Type
conference paper
Language
en
Open access
closed
Locations
  • Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) (publishedVersion)
  • Defense Technical Information Center (DTIC) (submittedVersion)
Topics
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Optical measurement and interference techniques
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced Measurement and Detection Methods
  • Health Sciences › Medicine › Surgery › Surgical Simulation and Training
Keywords
microsurgical instruments, infrared detection, microsurgical training, precision measurement

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Precision measurement for microsurgical instrument evaluation. https://app.cochat.ai/papers/10.1109/iembs.2001.1019573
The paper
Hotraphinyo, L. F., & Riviere, C. N. (2005). Precision measurement for microsurgical instrument evaluation. 2001 Conference Proceedings of the 23rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society. https://doi.org/10.1109/iembs.2001.1019573

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.