Cited by 15Motor Control and AdaptationNeural Networks and ApplicationsSurgical Simulation and Training

The DOI matches its Crossref record, with a small difference in title or year; 2 of the 2 references it cites were found in a registry or an index.

Neural network methods for error canceling in human-machine manipulation

Wei Tech Ang, Riviere, C.N.·2005·2001 Conference Proceedings of the 23rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society

Abstract

A neural network technique is employed to cancel hand motion error during microsurgery. A cascade-correlation neural network trained via extended Kalman filtering was tested on 15 recordings of hand movement collected from 4 surgeons. The neural network was trained to output the surgeon's desired motion, suppressing erroneous components. In experiments this technique reduced the root mean square error (rmse) of the erroneous motion by an average of 39.5%. This was 9.6% greater than the reduction achieved in earlier work, which followed the complementary approach of estimating the error rather than the desired component. Preliminary results are also presented from tests in which training and testing data were taken from different surgeons.

Overview

Integrity signals

Registry

Crossref · 10.1109/iembs.2001.1019575

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Preliminary tests of the neural-network error-canceling technique in simulation with recorded instrument motion data yielded an average rms error reduction of 40%.

    “Preliminary tests of this technique in simulation with recorded instrument motion data have yielded an average rms error reduction of 40% [25].”

Citations

Cites

Flagged first, then by citations

Research works printed but not linked: 12

  1. gonzalez, 1995, A new approach to suppressing abnormal tremor through signal equalization, Proc RESNA Annu Conf, 707
  2. nechyba, 1997, Learning and transfer of human real-time control strategies, J Adv Computational Intell, 1, 137
  3. 10.1109/ROBOT.1997.606884 · DOI · Paper page
  4. 10.1109/IJCNN.1991.155276 · DOI · Paper page
  5. elble, 1990, Tremor
  6. 10.1109/IEMBS.1997.757046 · DOI · Paper page
  7. 10.1162/pres.1993.2.4.265 · DOI · Paper page
  8. 10.1109/IEMBS.2000.900667 · DOI · Paper page
  9. schenker, 1995, Development of a telemanipulator for dexterity enhanced microsurgery, Proc 2nd Intl Symp Med Robot Comput Assist Surg, 81
  10. charles, 0, Dexterity enhancement for surgery, Computer Integrated Surgery Technology and Clinical Applications, 467
  11. 10.1111/j.1445-2197.1977.tb04297.x · DOI · Paper page
  12. riley, 1987, Evaluating manual control devices for those with tremor disability, J Rehabil Res Dev, 24, 99

Cited by

Sorted by citations

Metadata

Authors
Ang, W. T., & Riviere, C. N.
Affiliations
Carnegie Mellon University (US)
Venue
2001 Conference Proceedings of the 23rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society
Publisher
IEEE
Published
2005-08-25
Volume
4
Pages
3462-3465
ISSN
2375-7477 (ISSN-L)
OpenAlex
W2110452071
Cited by
15
References
2
Citations by year
2013: 2 · 2012: 1
FWCI
7.29
Type
conference paper
Language
en
Open access
closed
Locations
  • Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) (publishedVersion)
  • Defense Technical Information Center (DTIC) (submittedVersion)
Topics
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
  • Physical Sciences › Computer Science › Artificial Intelligence › Neural Networks and Applications
  • Health Sciences › Medicine › Surgery › Surgical Simulation and Training
Keywords
error cancellation, microsurgery, cascade correlation neural network, extended Kalman filter, motion suppression

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review