The DOI matches its Crossref record, with a small difference in title or year; 2 of the 2 references it cites were found in a registry or an index.
Neural network methods for error canceling in human-machine manipulation
Abstract
A neural network technique is employed to cancel hand motion error during microsurgery. A cascade-correlation neural network trained via extended Kalman filtering was tested on 15 recordings of hand movement collected from 4 surgeons. The neural network was trained to output the surgeon's desired motion, suppressing erroneous components. In experiments this technique reduced the root mean square error (rmse) of the erroneous motion by an average of 39.5%. This was 9.6% greater than the reduction achieved in earlier work, which followed the complementary approach of estimating the error rather than the desired component. Preliminary results are also presented from tests in which training and testing data were taken from different surgeons.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Preliminary tests of the neural-network error-canceling technique in simulation with recorded instrument motion data yielded an average rms error reduction of 40%.
“Preliminary tests of this technique in simulation with recorded instrument motion data have yielded an average rms error reduction of 40% [25].”
From Toward active tremor canceling in handheld microsurgical instruments (2003) · cites this paper as [25]
Citations
Cites
A Steady-Hand Robotic System for Microsurgical Augmentation
Taylor, R., Jensen, P., Whitcomb, L., Barnes, A., Kumar, R., Stoianovici, D., Gupta, P., Wang, Z., Dejuan, E., & Kavoussi, L. (1999) · The International Journal of Robotics Research · doi:10.1177/02783649922067807 · Cited by 528
Adaptive cancelling of physiological tremor for improved precision in microsurgery
Riviere, C. N., Rader, R. S., & Thakor, N. V. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.686791 · Cited by 260 · cited 1×
“[11] developed an adaptive filter to cancel physiological tremor during surgery, using an artificial frequency-modulated sinusoid as a reference.”
MethodSelf-citation
Flagged first, then by citations
Research works printed but not linked: 12
- gonzalez, 1995, A new approach to suppressing abnormal tremor through signal equalization, Proc RESNA Annu Conf, 707
- nechyba, 1997, Learning and transfer of human real-time control strategies, J Adv Computational Intell, 1, 137
- 10.1109/ROBOT.1997.606884 · DOI · Paper page
- 10.1109/IJCNN.1991.155276 · DOI · Paper page
- elble, 1990, Tremor
- 10.1109/IEMBS.1997.757046 · DOI · Paper page
- 10.1162/pres.1993.2.4.265 · DOI · Paper page
- 10.1109/IEMBS.2000.900667 · DOI · Paper page
- schenker, 1995, Development of a telemanipulator for dexterity enhanced microsurgery, Proc 2nd Intl Symp Med Robot Comput Assist Surg, 81
- charles, 0, Dexterity enhancement for surgery, Computer Integrated Surgery Technology and Clinical Applications, 467
- 10.1111/j.1445-2197.1977.tb04297.x · DOI · Paper page
- riley, 1987, Evaluating manual control devices for those with tremor disability, J Rehabil Res Dev, 24, 99
Cited by
Sorted by citations
Toward active tremor canceling in handheld microsurgical instruments
Riviere, C. N., Ang, W. T., & Khosla, P. K. (2003) · IEEE Transactions on Robotics and Automation · doi:10.1109/tra.2003.817506 · Cited by 245
Self-citationprecision measurement for microsurgical instrument evaluation
Hotraphinyo, L. F., & Riviere, C. N. (2005) · 2001 Conference Proceedings of the 23rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2001.1019573 · Cited by 28
Self-citation
Metadata
- Authors
- Ang, W. T., & Riviere, C. N.
- Affiliations
- Carnegie Mellon University (US)
- Venue
- 2001 Conference Proceedings of the 23rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Publisher
- IEEE
- Published
- 2005-08-25
- Volume
- 4
- Pages
- 3462-3465
- ISSN
- 2375-7477 (ISSN-L)
- OpenAlex
- W2110452071
- Cited by
- 15
- References
- 2
- Citations by year
- 2013: 2 · 2012: 1
- FWCI
- 7.29
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) (publishedVersion)
- Defense Technical Information Center (DTIC) (submittedVersion)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
- Physical Sciences › Computer Science › Artificial Intelligence › Neural Networks and Applications
- Health Sciences › Medicine › Surgery › Surgical Simulation and Training
- Keywords
- error cancellation, microsurgery, cascade correlation neural network, extended Kalman filter, motion suppression
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review