CoChat

Three-dimensional accuracy assessment of eye surgeons

Hotraphinyo, L.F., Riviere, C.N. · 2005 · 2001 Conference Proceedings of the 23rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society
Cited by 40

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Overall manual accuracy in simulated microsurgery has been studied. Three eye surgeons have been tested thus far. Subjects attempted to hold a microsurgical instrument still for 30 s and its 3-D tip position was recorded. RMS error, overall motion range were calculated and spectral analysis was performed for each axis. The RMS error was between 54 /spl mu/m and 118 /spl mu/m and the overall range of motion was between 239 /spl mu/m and 588 /spl mu/m, depending on the axis. Substantial low frequency motion was present. Between 73.5% and 83.7% of the total power was found to be below 3 Hz, depending on the axis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/iembs.2001.1019574

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Research works printed but not linked: 9

  1. 10.1109/IEMBS.1997.757046 · DOI · Paper page
  2. walsh, 1994, Physiological finger tremor in medical students and others, Neurol Dis Ther, 30, 63
  3. 10.1109/IEMBS.2001.1019573 · DOI · Paper page
  4. elble, 1990, Tremor
  5. riviere, 1996, Accuracy in positioning of handheld instruments, Proc 18th Annu Conf IEEE Eng Med Biol Soc
  6. ang, 2001, An intelligent hand-held microsurgical instrument for improved accuracy, 23rd Annu Int Conf IEEE Engineering Medicine Biology Society
  7. 10.1002/jor.1100070219 · DOI · Paper page
  8. schenker, 1995, Development of a telemanipulator for dexterity enhanced microsurgery, Proc 2nd Intl Symp Med Robot Comput Assist Surg, 81
  9. 10.1007/BF00336740 · DOI · Paper page

Cited by

See all 40

Metadata

Authors
Hotraphinyo, L. F., & Riviere, C. N.
Venue
2001 Conference Proceedings of the 23rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society
Publisher
IEEE
Published
2005-08-25
Volume
4
Pages
3458-3461
ISSN
2375-7477 (ISSN-L)
OpenAlex
W2159866098
Cited by
40
References
5
FWCI
24.68
Type
conference paper
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Three-dimensional accuracy assessment of eye surgeons. https://app.cochat.ai/papers/10.1109/iembs.2001.1019574
The paper
Hotraphinyo, L. F., & Riviere, C. N. (2005). Three-dimensional accuracy assessment of eye surgeons. 2001 Conference Proceedings of the 23rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society. https://doi.org/10.1109/iembs.2001.1019574

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.