Three-dimensional accuracy assessment of eye surgeons
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Overall manual accuracy in simulated microsurgery has been studied. Three eye surgeons have been tested thus far. Subjects attempted to hold a microsurgical instrument still for 30 s and its 3-D tip position was recorded. RMS error, overall motion range were calculated and spectral analysis was performed for each axis. The RMS error was between 54 /spl mu/m and 118 /spl mu/m and the overall range of motion was between 239 /spl mu/m and 588 /spl mu/m, depending on the axis. Substantial low frequency motion was present. Between 73.5% and 83.7% of the total power was found to be below 3 Hz, depending on the axis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Steady-Hand Robotic System for Microsurgical Augmentation
Taylor, R., Jensen, P., Whitcomb, L., Barnes, A., Kumar, R., Stoianovici, D., Gupta, P., Wang, Z., Dejuan, E., & Kavoussi, L. (1999) · The International Journal of Robotics Research · doi:10.1177/02783649922067807 · Cited by 528
Adaptive cancelling of physiological tremor for improved precision in microsurgery
Riviere, C. N., Rader, R. S., & Thakor, N. V. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.686791 · Cited by 260 · cited 1×
“Research into microsurgical error suppression has involved teleoperated systems [2l, cooperative-control “steady-hand” systems [4], and active hand-held instruments [5, 6 ].”
Self-citationA teleoperated microsurgical robot and associated virtual environment for eye surgery
Hunter, I. W., Doukoglou, T. D., Lafontaine, S. R., Charette, P. G., Jones, L. A., Sagar, M. A., Mallinson, G. D., & Hunter, P. J. (1993) · Presence: Teleoperators and Virtual Environments · doi:10.1162/pres.1993.2.4.265 · Cited by 164
Physiologic tremor and microsurgery
Harwell, R. C., & Ferguson, R. L. (1983) · Microsurgery · doi:10.1002/micr.1920040310 · Cited by 131
neural network methods for error canceling in human-machine manipulation
Ang, W. T., & Riviere, C. N. (2005) · 2001 Conference Proceedings of the 23rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2001.1019575 · Cited by 15
Self-citation
Research works printed but not linked: 9
- 10.1109/IEMBS.1997.757046 · DOI · Paper page
- walsh, 1994, Physiological finger tremor in medical students and others, Neurol Dis Ther, 30, 63
- 10.1109/IEMBS.2001.1019573 · DOI · Paper page
- elble, 1990, Tremor
- riviere, 1996, Accuracy in positioning of handheld instruments, Proc 18th Annu Conf IEEE Eng Med Biol Soc
- ang, 2001, An intelligent hand-held microsurgical instrument for improved accuracy, 23rd Annu Int Conf IEEE Engineering Medicine Biology Society
- 10.1002/jor.1100070219 · DOI · Paper page
- schenker, 1995, Development of a telemanipulator for dexterity enhanced microsurgery, Proc 2nd Intl Symp Med Robot Comput Assist Surg, 81
- 10.1007/BF00336740 · DOI · Paper page
Cited by
Toward active tremor canceling in handheld microsurgical instruments
Riviere, C. N., Ang, W. T., & Khosla, P. K. (2003) · IEEE Transactions on Robotics and Automation · doi:10.1109/tra.2003.817506 · Cited by 245
Self-citationLadha, R., Meenink, T., Smit, J., & de Smet, M. D. (2023) · Gene Therapy · doi:10.1038/s41434-021-00262-w · Cited by 42
precision measurement for microsurgical instrument evaluation
Hotraphinyo, L. F., & Riviere, C. N. (2005) · 2001 Conference Proceedings of the 23rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2001.1019573 · Cited by 28
Self-citationDesign and Calibration of an Optical Micro Motion Sensing System for Micromanipulation Tasks
Win, T. L., Tan, U. X., Shee, C. Y., & Ang, W. T. (2007) · Proceedings 2007 IEEE International Conference on Robotics and Automation · doi:10.1109/robot.2007.363995 · Cited by 25
Metadata
- Authors
- Hotraphinyo, L. F., & Riviere, C. N.
- Venue
- 2001 Conference Proceedings of the 23rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Publisher
- IEEE
- Published
- 2005-08-25
- Volume
- 4
- Pages
- 3458-3461
- ISSN
- 2375-7477 (ISSN-L)
- OpenAlex
- W2159866098
- Cited by
- 40
- References
- 5
- FWCI
- 24.68
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Three-dimensional accuracy assessment of eye surgeons. https://app.cochat.ai/papers/10.1109/iembs.2001.1019574
- The paper
- Hotraphinyo, L. F., & Riviere, C. N. (2005). Three-dimensional accuracy assessment of eye surgeons. 2001 Conference Proceedings of the 23rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society. https://doi.org/10.1109/iembs.2001.1019574
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.