Models of stimulation artifacts applied to integrated circuit design
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The goal of this research is to develop a monolithic stimulation and recording system capable of simultaneous, multichannel stimulation and recording. Monolithic systems are advantageous for large numbers of recording sites because they scale better than systems composed of discrete amplifiers. A major problem in recording systems is the stimulation artifact, a transient distortion present after stimulation. In order to improve recording systems, we analyze models of the stimulation artifact. Comparisons between model predictions and physical measurements verify the models. We show that the linear model, suitable for inclusion in circuit simulators, can assist in the design of an integrated recording system capable of artifact removal. The proposed design occupies 18,000 micron(2) and is suitable for monolithic integration.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A low-power low-noise cmos for amplifier neural recording applications
Harrison, R. R., & Charles, C. (2003) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2003.811979 · Cited by 1,695
An implantable multielectrode array with on-chip signal processing
Najafi, K., & Wise, K. D. (1986) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.1986.1052646 · Cited by 310 · cited 1×
“Integrated circuits, which offer a correspondingly high density of electronics, are a natural partner to MEAs [5][6][7].”
Background
Cited by
The 128-Channel Fully Differential Digital Integrated Neural Recording and Stimulation Interface
Shahrokhi, F., Abdelhalim, K., Serletis, D., Carlen, P. L., & Genov, R. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2041350 · Cited by 263
Integrated circuit amplifiers for multi-electrode intracortical recording
Jochum, T., Denison, T., & Wolf, P. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/1/012001 · Cited by 167
Toward true closed-loop neuromodulation: artifact-free recording during stimulation.
Zhou, A., Johnson, B. C., & Muller, R. (2018) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2018.01.012 · Cited by 125
Stimulus-artifact elimination in a multi-electrode system.
Brown, E. A., Ross, J. D., Blum, R. A., Nam, Y., Wheeler, B. C., & DeWeerth, S. P. (2008) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2008.918285 · Cited by 95
An integrated system for simultaneous, multichannel neuronal stimulation and recording.
Blum, R. A., Ross, J. D., Brown, E. A., & DeWeerth, S. P. (2007) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2007.906071 · Cited by 74
Self-citation
Metadata
- Authors
- Blum, R. A., Ross, J. D., Das, S. K., Brown, E. A., & DeWeerth, S. P.
- Venue
- The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Publisher
- IEEE
- Published
- 2005-04-06
- Volume
- 4
- Pages
- 4075-4078
- OpenAlex
- W2543479983
- Cited by
- 21
- References
- 2
- FWCI
- 6.21
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Models of stimulation artifacts applied to integrated circuit design. https://app.cochat.ai/papers/10.1109/iembs.2004.1404137
- The paper
- Blum, R. A., Ross, J. D., Das, S. K., Brown, E. A., & DeWeerth, S. P. (2005). Models of stimulation artifacts applied to integrated circuit design. The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. https://doi.org/10.1109/iembs.2004.1404137
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.