An integrated system for simultaneous, multichannel neuronal stimulation and recording.
Abstract
Precision electronics that provide multi-electrode stimulation and recording capabilities are an important tool for the experimental study of neuronal development and plasticity. Towards this end, we present a custom analog integrated circuit (IC), fabricated in a 0.35-mum process, incorporating stimulation buffers and recording preamplifiers for multiple electrodes onto a single die. The architecture of the IC allows for arbitrary, independent configuration of electrodes for stimulation or recording, and the IC includes artifact-elimination circuitry that returns the stimulation electrode to its previous voltage following stimulation, minimizing the interference with recording. We analyze the thermal noise levels in the recording preamplifiers and experimentally measure input-referred noise as low as 4.77 muVrmsin the frequency range of 30 Hz-3 kHz at a power consumption of 100 muW from a total power supply of 3.8 V. We also consider the temporal response and stability of the artifact elimination circuitry. We demonstrate that the use of the artifact-elimination circuitry with a 30-mum diameter stimulation electrode permits a return to recording mode in les 2 ms after stimulation, facilitating near-simultaneous stimulation and recording of neuronal signals. (Patent applied for, U.S. No. 2007/0178579.)
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The blanking technique is effective in some applications, such as EMG signal acquisition.
“This method is effective in some applications, such as EMG signal acquisition.”
From Advances in Neural Recording and Stimulation Integrated Circuits (2021) · cites this paper as Blum et al., 2007
Such a stimulation artifact can be observed in most closed-loop recording and stimulation circuits.
“Such a stimulation artifact can be observed in most of the closed-loop recording and stimulation circuits (Yoshida and Horch, 1996; Blum et al., 2007; Venkatraman et al., 2009; Mc Laughlin et al., 2012; Ng et al., 2012; Xu et al., 2012).”
From Advances in Neural Recording and Stimulation Integrated Circuits (2021) · cites this paper as Blum et al., 2007
Cites
Analog VLSI and Neural Systems
Mead, C. (1989) · CaltechAUTHORS (California Institute of Technology) · Cited by 2,794 · see citing works
A low-power low-noise cmos for amplifier neural recording applications
Harrison, R. R., & Charles, C. (2003) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2003.811979 · Cited by 1,695 · see citing works
Analog VLSI Implementation of Neural Systems
(1989) · Kluwer international series in engineering and computer science · doi:10.1007/978-1-4613-1639-8 · Cited by 1,684 · see citing works
Impedance Characterization and Modeling of Electrodes for Biomedical Applications
Franks, W., Schenker, I., Schmutz, P., & Hierlemann, A. R. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.847523 · Cited by 660 · see citing works
A miniature microelectrode array to monitor the bioelectric activity of cultured cells
THOMASJR, C., SPRINGER, P., Loeb, G. E., Berwald‐Netter, Y., & Okun, L. M. (1972) · Experimental Cell Research · doi:10.1016/0014-4827(72)90481-8 · Cited by 580 · see citing works
A micropower low-noise monolithic instrumentation amplifier for medical purposes
Steyaert, M. S. J., & Sansen, W. M. C. (1987) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.1987.1052869 · Cited by 577 · see citing works
Recording action potentials from cultured neurons with extracellular microcircuit electrodes
Pine, J. (1980) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(80)90042-4 · Cited by 545 · see citing works
A new approach to neural cell culture for long-term studies
Potter, S. M., & DeMarse, T. B. (2001) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(01)00412-5 · Cited by 491 · see citing works
The electrical properties of metal microelectrodes
Robinson, D. A. (1968) · Proceedings of the IEEE · doi:10.1109/proc.1968.6458 · Cited by 459 · see citing works
Jimbo, Y., Tateno, T., & Robinson, H. P. C. (1999) · Biophysical Journal · doi:10.1016/s0006-3495(99)77234-6 · Cited by 397 · see citing works
Electrical Interactions via the Extracellular Potential Near Cell Bodies
Holt, G. R., & Koch, C. (1999) · Journal of Computational Neuroscience · doi:10.1023/a:1008832702585 · Cited by 360 · see citing works
Charge injection in analog MOS switches
Wegmann, G., Vittoz, E. A., & Rahali, F. (1987) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.1987.1052859 · Cited by 326 · see citing works
Gesteland, R. C., Howland, B., Lettvin, J. Y., & Pitts, W. (1959) · Proceedings of the IRE · doi:10.1109/jrproc.1959.287156 · Cited by 302 · see citing works
Effective parameters for stimulation of dissociated cultures using multi-electrode arrays
Wagenaar, D. A., Pine, J., & Potter, S. M. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.03.005 · Cited by 300 · see citing works
The Neurally Controlled Animat: Biological Brains Acting with Simulated Bodies
DeMarse, T. B., Wagenaar, D. A., Blau, A. W., & Potter, S. M. (2001) · Autonomous Robots · doi:10.1023/a:1012407611130 · Cited by 278 · see citing works
Real-time multi-channel stimulus artifact suppression by local curve fitting
Wagenaar, D. A., & Potter, S. M. (2002) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(02)00149-8 · Cited by 224 · see citing works
Single-unit neural recording with active microelectrode arrays
Bai, Q., & Wise, K. D. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.936367 · Cited by 214 · see citing works
Enabling Technologies for Cultured Neural Networks
Stenger, D. A., & McKenna, T. M. (1994) · Cited by 213 · see citing works
A system for MEA-based multisite stimulation
Jimbo, Y., Kasai, N., Torimitsu, K., Tateno, T., & Robinson, H. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2002.805470 · Cited by 202 · see citing works
Adaptive photoreceptor with wide dynamic range
Delbrück, T., & Mead, C. (2002) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.1994.409266 · Cited by 188 · see citing works
Measurement and analysis of charge injection in MOS analog switches
Shieh, J.-H., Patil, M., & Sheu, B. J. (1987) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.1987.1052713 · Cited by 184 · see citing works
Multi-electrode stimulation and recording in the isolated retina
Grumet, A., Wyatt, J. L., & Rizzo, J. F. (2000) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(00)00246-6 · Cited by 167 · see citing works
Reduction of Quantizing Noise by Use of Feedback
Spang, H. A., & Schultheiss, P. M. (1962) · IRE Transactions on Communications Systems · doi:10.1109/tcom.1962.1088681 · Cited by 120 · see citing works
Multisite hippocampal slice recording and stimulation using a 32 element microelectrode array
Novak, J. L., & Wheeler, B. C. (1988) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(88)90187-2 · Cited by 105 · see citing works
Preparation of strongly adherent platinum black coatings
Marrese, C. A. (1987) · Analytical Chemistry · doi:10.1021/ac00128a049 · Cited by 96 · see citing works
A versatile all-channel stimulator for electrode arrays, with real-time control
Wagenaar, D. A., & Potter, S. M. (2004) · Journal of Neural Engineering · doi:10.1088/1741-2560/1/1/006 · Cited by 92 · see citing works
Stimulus artifact removal using a software-based two-stage peak detection algorithm
O'Keeffe, D. T., Lyons, G. M., Donnelly, A., & Byrne, C. (2001) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(01)00407-1 · Cited by 90 · see citing works
Pancrazio, J. J., Bey, P., Loloee, A., Manne, S., Chao, H.-C., Howard, L. L., Gosney, W., Borkholder, D. A., Kovacs, G. T. A., Manos, P., et al. (1998) · Biosensors & bioelectronics · doi:10.1016/s0956-5663(98)00006-2 · Cited by 78 · see citing works
Brain–Silicon Interface for High-Resolution in vitro Neural Recording
Aziz, J. N. Y., Genov, R., Bardakjian, B. L., Derchansky, M., & Carlen, P. L. (2007) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2007.893181 · Cited by 58 · see citing works
Extracellular potentials in low-density dissociated neuronal cultures
Claverol-Tinturé, E., & Pine, J. (2002) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(02)00043-2 · Cited by 52 · see citing works
Dąbrowski, W., Gryboś, P., & Litke, A. M. (2003) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2003.08.005 · Cited by 52 · see citing works
Spectral cancellation of microstimulation artifact for simultaneous neural recording in situ
Gnadt, J., Echols, S. D., Yildirim, A., Zhang, H., & Paul, K. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.816077 · Cited by 45 · see citing works
Subthreshold analysis of an MOS analog switch
Aghtar, S., Haslett, J. W., & Trofimenkoff, F. N. (1997) · IEEE Transactions on Electron Devices · doi:10.1109/16.554798 · Cited by 26 · see citing works
Models of stimulation artifacts applied to integrated circuit design
Blum, R. A., Ross, J. D., Das, S. K., Brown, E. A., & DeWeerth, S. P. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2004.1404137 · Cited by 21 · see citing works
Self-citationMultielectrode impedance tuning: reducing noise and improving stimulation efficacy
Ross, J. D., O'Connor, S. M., Blum, R. A., Brown, E. A., & DeWeerth, S. P. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2004.1404148 · Cited by 18 · see citing works
Self-citation
Flagged first, then by citations
Cited by
Sorted by citations
Mahdiani, H. R., Ahmadi, A.-A., Fakhraie, S. M., & Lucas, C. L. (2010) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2009.2027626 · Cited by 621 · see citing works
The 128-Channel Fully Differential Digital Integrated Neural Recording and Stimulation Interface
Shahrokhi, F., Abdelhalim, K., Serletis, D., Carlen, P. L., & Genov, R. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2041350 · Cited by 263 · see citing works
Integrated circuit amplifiers for multi-electrode intracortical recording
Jochum, T., Denison, T., & Wolf, P. D. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/1/012001 · Cited by 167 · see citing works
Compound action potentials recorded in the human spinal cord during neurostimulation for pain relief
Parker, J. L., Karantonis, D. M., Single, P. S., Obradovic, M., & Cousins, M. J. (2011) · Pain · doi:10.1016/j.pain.2011.11.023 · Cited by 158 · see citing works
Imfeld, K., Neukom, S., Maccione, A., Bornat, Y., Sergio Martinoia, A., Farine, P.-A., Koudelka‐Hep, M., & Berdondini, L. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.919139 · Cited by 140 · see citing works
Toward true closed-loop neuromodulation: artifact-free recording during stimulation.
Zhou, A., Johnson, B. C., & Muller, R. (2018) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2018.01.012 · Cited by 125 · see citing works
Stimulus-artifact elimination in a multi-electrode system.
Brown, E. A., Ross, J. D., Blum, R. A., Nam, Y., Wheeler, B. C., & DeWeerth, S. P. (2008) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2008.918285 · Cited by 95 · see citing works
Self-citationA Wireless Integrated Circuit for 100-Channel Charge-Balanced Neural Stimulation
Thurgood, B., Warren, D. J., Ledbetter, N. M., Clark, G. A., & Harrison, R. R. (2009) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2009.2032268 · Cited by 93 · see citing works
Low-Power Circuits for Brain–Machine Interfaces
Sarpeshkar, R., Wattanapanitch, W., Arfin, S. K., Rapoport, B. I., Mandal, S., Baker, M. W., Fee, M. S., Musallam, S., & Andersen, R. A. (2008) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2008.2003198 · Cited by 91 · see citing works
Rolston, J. D. (2009) · Frontiers in Neuroengineering · doi:10.3389/neuro.16.012.2009 · Cited by 86 · see citing works
A Compact, Low Input Capacitance Neural Recording Amplifier
Ng, K. A., & Xu, Y. P. (2013) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2013.2280066 · Cited by 81 · see citing works
Joye, N., Schmid, A., & Leblebici, Y. (2009) · Neurocomputing · doi:10.1016/j.neucom.2009.09.006 · Cited by 70 · see citing works
Zhu, B., Shin, U., & Shoaran, M. (2021) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2021.3112756 · Cited by 67 · see citing works
Mahdiani, H. R., Fakhraie, S. M., & Lucas, C. L. (2012) · IEEE Transactions on Neural Networks and Learning Systems · doi:10.1109/tnnls.2012.2199517 · Cited by 62 · see citing works
A 128-Channel FPGA-Based Real-Time Spike-Sorting Bidirectional Closed-Loop Neural Interface System
Park, J., Kim, G., & Jung, S.-D. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2017.2697415 · Cited by 59 · see citing works
Beyond Tissue replacement: The Emerging role of smart implants in healthcare
Abyzova, E., Dogadina, E., Rodriguez, R. D. D., Petrov, I., Kolesnikova, Y., Zhou, M., Liu, C., & Sheremet, E. S. (2023) · Materials Today Bio · doi:10.1016/j.mtbio.2023.100784 · Cited by 56 · see citing works
Didier, C. M., Kundu, A., DeRoo, D., & Rajaraman, S. (2020) · Journal of Micromechanics and Microengineering · doi:10.1088/1361-6439/ab8e91 · Cited by 52 · see citing works
Kent, A. R., & Grill, W. M. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/3/036004 · Cited by 49 · see citing works
32.9 nV/rt Hz ${-}$60.6 dB THD Dual-Band Micro-Electrode Array Signal Acquisition IC
Guo, J., Yuan, J., Huang, J., Law, J. K.-Y., Yeung, C.-K., & Chan, M. (2012) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2012.2185590 · Cited by 45 · see citing works
Real-Time Stimulus Artifact Rejection Via Template Subtraction
Limnuson, K., Lu, H., Chiel, H. J., & Mohseni, P. (2013) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2013.2274574 · Cited by 36 · see citing works
Design andin vivoevaluation of more efficient and selective deep brain stimulation electrodes
Howell, B. L., Huynh, B., & Grill, W. M. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/4/046030 · Cited by 36 · see citing works
Low-Power Circuits for Brain-Machine Interfaces
Sarpeshkar, R., Wattanapanitch, W., Rapoport, B. I., Arfin, S. K., Baker, M., Mandal, S., Fee, M. S., Musallam, S., & Andersen, R. A. (2007) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2007.378505 · Cited by 31 · see citing works
64 Channel Neural Recording Amplifier with Tunable Bandwidth in 180 nm CMOS Technology
Gryboś, P., Kmon, P., Żołądź, M., Szczygieł, R., Kachel, M., Lewandowski, M. H., & Błasiak, T. (2011) · Metrology and Measurement Systems · doi:10.2478/v10178-011-0060-x · Cited by 29 · see citing works
Tsai, D., John, E., Chari, T. R., Yuste, R., & Shepard, K. L. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7320129 · Cited by 28 · see citing works
Shadmani, A., Viswam, V., Chen, Y., Bounik, R., Dragas, J., Radivojevic, M., Geissler, S., Sitnikov, S., Muller, J., & Hierlemann, A. (2019) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2890530 · Cited by 24 · see citing works
Advances in Neural Recording and Stimulation Integrated Circuits
Li, J., Liu, X., Mao, W., Chen, T., & Yu, H. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.663204 · Cited by 21 · see citing works
Sensing of stimulus artifact suppressed signals from electrode interfaces.
Nag, S., Sikdar, S. K., Thakor, N. V., Rao, V. R., & Sharma, D. (2015) · IEEE Sensors Journal · doi:10.1109/jsen.2015.2399248 · Cited by 20 · see citing works
Selective Stimulation of the Spinal Cord Surface Using a Stretchable Microelectrode Array
Meacham, K., Guo, L., DeWeerth, S. P., & Hochman, S. (2011) · Frontiers in Neuroengineering · doi:10.3389/fneng.2011.00005 · Cited by 20 · see citing works
Self-citationDebarros, J., Gaignon, L., He, S., Pogosyan, A. H., Benjaber, M., Denison, T., Brown, P., & Tan, H. (2020) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc44109.2020.9176665 · Cited by 19 · see citing works
Qiu, Z., Nguyen, A. T., Su, K., Yang, Z., & Xu, J. (2023) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2023.3321295 · Cited by 18 · see citing works
A bidirectional 64-channel neurochip for recording and stimulation neural network activity
Żołądź, M., Kmon, P., Gryboś, P., Szczygieł, R., Kłeczek, R., & Otfinowski, P. (2011) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2011.5910566 · Cited by 18 · see citing works
Huang, C.-W., Lai, C.-K., Hung, C.-C., Wu, C.-Y., & Ker, M.-D. (2023) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2023.3254891 · Cited by 16 · see citing works
Limnuson, K., Lu, H., Chiel, H. J., & Mohseni, P. (2015) · Analog Integrated Circuits and Signal Processing · doi:10.1007/s10470-015-0489-z · Cited by 15 · see citing works
Active Pixel Sensor Multielectrode Array for High Spatiotemporal Resolution
Berdondini, L., Bosca, A., Nieus, T. R., & Maccione, A. (2014) · Springer eBooks · doi:10.1007/978-1-4899-8038-0_7 · Cited by 14 · see citing works
A New System Architecture for Future Long-Term High-Density Neural Recording
Xu, J., Wu, T. F., & Yang, Z. (2013) · IEEE Transactions on Circuits & Systems II Express Briefs · doi:10.1109/tcsii.2013.2258270 · Cited by 12 · see citing works
Carlino, M. F., & Gielen, G. E. (2023) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2023.3344889 · Cited by 10 · see citing works
An HFAC block-capable and module-extendable 4-channel stimulator for acute neurophysiology
Rapeaux, A., & Constandinou, T. G. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab947a · Cited by 9 · see citing works
Brain Function: Novel Technologies Driving Novel Understanding
Assad, J. A., Berdondini, L., Cancedda, L., Angelis, F. D., Diaspro, A., Dipalo, M., Fellin, T., Maccione, A., Panzeri, S., & Sileo, L. (2014) · Springer eBooks · doi:10.1007/978-3-319-04924-3_10 · Cited by 7 · see citing works
Żołądź, M., Kmon, P., Gryboś, P., Szczygieł, R., Kłeczek, R., Otfinowski, P., & Rauza, J. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6346959 · Cited by 6 · see citing works
Highly Accurate Dual-Band Cellular Field Potential Acquisition For Brain–Machine Interface
Guo, J., Yuan, J. G., Huang, J., Law, J. K. Y., Yeung, C. K., & Chan, M. (2011) · IEEE Journal on Emerging and Selected Topics in Circuits and Systems · doi:10.1109/jetcas.2011.2174471 · Cited by 6 · see citing works
An electronic system for extracellular neural stimulation and recording
Blum, R. A. (2007) · SMARTech Repository (Georgia Institute of Technology) · Cited by 6 · see citing works
Self-citationA new approach to design safe and reliable electrical stimulator
Moradi, S., Maghsoudloo, E., & Lotfi, R. (2014) · International Journal of Biomedical Engineering and Technology · doi:10.1504/ijbet.2014.064820 · Cited by 5 · see citing works
Stimulation and recording of neural tissue, closing the loop on the artifact
Brown, E. A., Ross, J. D., Blum, R. A., & DeWeerth, S. P. (2008) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2008.4541428 · Cited by 5 · see citing works
Self-citationChen, Y., Lee, Y., Yeh, S., & Chen, H. (2009) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2009.5109231 · Cited by 5 · see citing works
Mixed-signal template-based reduction scheme for stimulus artifact removal in electrical stimulation
Nguyen, T. K. T., Musa, S., Eberle, W., Bartic, C., & Gielen, G. E. (2012) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-012-1013-6 · Cited by 3 · see citing works
Diamond-based technology dedicated to Micro Electrode Arrays for neuronal prostheses
Bongrain, A., Bendali, A., Lissorgues, G., Rousseau, L., Yvert, B., Scorsone, E., Bergonzo, P., & Picaud, S. A. (2011) · UCL Discovery (University College London) · Cited by 3 · see citing works
Spatiotemporal scales and links between electrical neuroimaging modalities
Andino, S. L. G., Perrig, S. H., & Menéndez, R. G. D. P. (2011) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-011-0769-4 · Cited by 3 · see citing works
Szypulska, M., Dwužnik, M., Wiacek, P. K., Skoczeń, A., Fiutowski, T., Jedraczka, M., Dusik, J., Ahmed, M. I., Dąbrowski, W., Hottowy, P., et al. (2016) · International Conference Mixed Design of Integrated Circuits and Systems · doi:10.1109/mixdes.2016.7529735 · Cited by 3 · see citing works
der Spiegel, J. V., Zhang, M., & Liu, X. (2017) · IEEE International Conference on ASIC (ASICON) · doi:10.1109/asicon.2017.8252507 · Cited by 3 · see citing works
Nag, S., Sharma, D., & Thakor, N. V. (2015) · Cambridge University Press eBooks · doi:10.1017/cbo9781139629539.036 · Cited by 3 · see citing works
A Wireless Fully Implantable DBS Device for Closed-Loop Neuromodulation Applications
Su, K., Qiu, Z., Xu, K., Xu, J., & Wang, Y. (2025) · IEEE Sensors Journal · doi:10.1109/jsen.2025.3549370 · Cited by 2 · see citing works
A real-time system for multisite stimulation on living neural networks
Bontorin, G., Garenne, A., Tomas, J., Lopez, C., Morin, F. O., & Renaud, S. (2009) · Joint IEEE North-East Workshop on Circuits and Systems and TAISA Conference (NEWCAS-TAISA) · doi:10.1109/newcas.2009.5290451 · Cited by 2 · see citing works
A stimulator ASIC with capability of neural recording during inter-phase delay
Liu, X., Demosthenous, A., Jiang, D., Vanhoestenberghe, A., & Donaldson, N. (2011) · European Solid-State Circuits Conference (ESSCIRC) · doi:10.1109/esscirc.2011.6044903 · Cited by 2 · see citing works
A Neural Recording and Stimulation Chip with Artifact Suppression for Biomedical Devices
Liu, X., Li, J., Chen, T., Wang, W., & Je, M. (2021) · Journal of Healthcare Engineering · doi:10.1155/2021/4153155 · Cited by 2 · see citing works
A real-time system for multisite stimulation on living neural networks
Bontorin, G., Garenne, A., Tomas, J., Lopez, C., Morin, F. O., & Renaud, S. (2009) · Joint IEEE North-East Workshop on Circuits and Systems and TAISA Conference (NEWCAS-TAISA) · doi:10.1109/newcas.2009.5290511 · Cited by 2 · see citing works
Moradi, S., Maghsoudloo, E., & Lotfi, R. (2012) · Iranian Conference on Electrical Engineering · doi:10.1109/iraniancee.2012.6292367 · Cited by 1 · see citing works
Selective surface activation of motor circuitry in the injured spinal cord
Meacham, K. (2008) · SMARTech Repository (Georgia Institute of Technology) · Cited by 1 · see citing works
Development of a Bi-Directional Electronics Platform for Advanced Neural Applications
Abbati, L. (2012) · Digital Commons - University of South Florida (University of South Florida) · Cited by 1 · see citing works
Low noise and low power multichannel integrated circuit for recording neural spikes and LFP signals
Kmon, P., Żołądź, M., Gryboś, P., & Szczygieł, R. (2011) · Elektronika : konstrukcje, technologie, zastosowania
Kmon, P., Gryboś, P., Szczygieł, R., & Żołądź, M. (2011) · European Conference on Circuit Theory and Design · doi:10.1109/ecctd.2011.6043346
An integrated system for brain machine interface
Chiu, H.-C., Chuang, C.-F., Chen, Y., Fan, Y.-H., Kao, Y.-H., Ma, H., Chen, H., Chang, Y., & Yeh, S.-R. (2012) · IEEE International Conference on e-Health Networking, Applications and Services (Healthcom) · doi:10.1109/healthcom.2012.6380812
Stimulation and Recording of Neural Tissue, Closing the Loop on the Artifact (Invited Paper)
Brown, E. A., Ross, J. D. C., Blum, R. A., & DeWeerth, S. P. (2008)
Self-citationSELECTIVE SURFACE ACTIVATION OF MOTOR CIRCUITRY IN
Meacham, K. (2008)
Liu, X., & der Spiegel, J. V. (2017) · Springer eBooks · doi:10.1007/978-3-319-67940-2_4
A simultaneous neural recording and stimulation system using signal folding in recording circuits
Yi, C., Basu, A., Liu, X., Yao, L., Nag, S., Je, M., & Thakor, N. V. (2017) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2017.8325190
Liu, X., & der Spiegel, J. V. (2017) · Springer eBooks · doi:10.1007/978-3-319-67940-2_1
Hsu, C.-H., Lin, Y.-W., & Tang, K. (2024) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas58744.2024.10558265
Wang, W., Zheng, J., Zhou, Y., Su, R., Zhu, L., & Zhou, Z. (2024) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas58744.2024.10558281
de Oliveira, J. V., Weiss, N. M., Wollenberg, B., & Wimmer, W. (2026) · Zeitschrift für Medizinische Physik · doi:10.1016/j.zemedi.2026.10.002
- Authors
- Blum, R. A., Ross, J. D., Brown, E. A., & DeWeerth, S. P.
- Affiliations
- Georgia Institute of Technology (US)
- Venue
- IEEE Transactions on Circuits and Systems I Regular Papers
- Published
- 2007-12
- Volume
- 54
- Issue
- 12
- Pages
- 2608-2618
- ISSN
- 1549-8328 (ISSN-L)
- 1558-0806
- OpenAlex
- W1964974938
- Cited by
- 74
- References
- 35
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 2 · 2023: 4 · 2021: 3 · 2020: 3 · 2019: 1 · 2018: 1 · 2017: 6 · 2016: 1 · 2015: 5 · 2014: 4 · 2013: 3 · 2012: 8
- FWCI
- 4.55
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Circuits and Systems I Regular Papers (publishedVersion)
- Funders
- Korea Institute of Science and Technology
- Korea Advanced Institute of Science and Technology
- Wallace H. Coulter Department of Biomedical Engineering
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Analog and Mixed-Signal Circuit Design
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Radio Frequency Integrated Circuit Design
- Keywords
- integrated circuits, artifact removal, thermal noise, input-referred noise, low-power analog circuits, neuroplasticity, neuronal development
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review