Cited by 74Analog and Mixed-Signal Circuit DesignNeuroscience and Neural EngineeringRadio Frequency Integrated Circuit Design

An integrated system for simultaneous, multichannel neuronal stimulation and recording.

Blum, R.A., Ross, J.D., Brown, E.A., DeWeerth, S.P.·2007·IEEE Transactions on Circuits and Systems I Regular Papers

Abstract

Precision electronics that provide multi-electrode stimulation and recording capabilities are an important tool for the experimental study of neuronal development and plasticity. Towards this end, we present a custom analog integrated circuit (IC), fabricated in a 0.35-mum process, incorporating stimulation buffers and recording preamplifiers for multiple electrodes onto a single die. The architecture of the IC allows for arbitrary, independent configuration of electrodes for stimulation or recording, and the IC includes artifact-elimination circuitry that returns the stimulation electrode to its previous voltage following stimulation, minimizing the interference with recording. We analyze the thermal noise levels in the recording preamplifiers and experimentally measure input-referred noise as low as 4.77 muVrmsin the frequency range of 30 Hz-3 kHz at a power consumption of 100 muW from a total power supply of 3.8 V. We also consider the temporal response and stability of the artifact elimination circuitry. We demonstrate that the use of the artifact-elimination circuitry with a 30-mum diameter stimulation electrode permits a return to recording mode in les 2 ms after stimulation, facilitating near-simultaneous stimulation and recording of neuronal signals. (Patent applied for, U.S. No. 2007/0178579.)

Integrity signals

Registry

Crossref · 10.1109/tcsi.2007.906071

Cites

35 of 35 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The blanking technique is effective in some applications, such as EMG signal acquisition.

    “This method is effective in some applications, such as EMG signal acquisition.”

    From Advances in Neural Recording and Stimulation Integrated Circuits (2021) · cites this paper as Blum et al., 2007

  • Such a stimulation artifact can be observed in most closed-loop recording and stimulation circuits.

    “Such a stimulation artifact can be observed in most of the closed-loop recording and stimulation circuits (Yoshida and Horch, 1996; Blum et al., 2007; Venkatraman et al., 2009; Mc Laughlin et al., 2012; Ng et al., 2012; Xu et al., 2012).”

    From Advances in Neural Recording and Stimulation Integrated Circuits (2021) · cites this paper as Blum et al., 2007

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Blum, R. A., Ross, J. D., Brown, E. A., & DeWeerth, S. P.
Affiliations
Georgia Institute of Technology (US)
Venue
IEEE Transactions on Circuits and Systems I Regular Papers
Published
2007-12
Volume
54
Issue
12
Pages
2608-2618
ISSN
  • 1549-8328 (ISSN-L)
  • 1558-0806
OpenAlex
W1964974938
Cited by
74
References
35
Citations by year
2026: 1 · 2025: 1 · 2024: 2 · 2023: 4 · 2021: 3 · 2020: 3 · 2019: 1 · 2018: 1 · 2017: 6 · 2016: 1 · 2015: 5 · 2014: 4 · 2013: 3 · 2012: 8
FWCI
4.55
Type
journal article
Language
en
Open access
closed
Locations
IEEE Transactions on Circuits and Systems I Regular Papers (publishedVersion)
Funders
  • Korea Institute of Science and Technology
  • Korea Advanced Institute of Science and Technology
  • Wallace H. Coulter Department of Biomedical Engineering
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Analog and Mixed-Signal Circuit Design
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Radio Frequency Integrated Circuit Design
Keywords
integrated circuits, artifact removal, thermal noise, input-referred noise, low-power analog circuits, neuroplasticity, neuronal development

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review