The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Wearable medical devices for tele-home healthcare
Abstract
The world's ageing population and prevalence of chronic diseases have lead to high demand for tele-home healthcare, in which vital-signs monitoring is essential. An overview of state-of-art wearable technologies for remote patient-monitoring is presented, followed by case studies on a cuffless blood pressure meter, ring-type heart rate monitor, and Bluetoothtrade mark-based ECG monitor. Aim of our project is to develop a tele-home healthcare system which utilizes wearable devices, wireless communication technologies, and multisensor data fusion methods. As an important part of this system, a cuffless BP meter has been developed and tested on 30 subjects in a total of 71 trials over a period of five months. Preliminary results show a mean error (ME) of 1.82 mmHg and standard deviation of error (SDE) of 7.62 mmHg in systolic pressure; while ME and SDE in diastolic pressure are 0.45 mmHg and 5.27 mmHg, respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mobile monitoring with wearable photoplethysmographic biosensors
Asada, H. H., Shaltis, P., Reisner, A., Rhee, S., & Hutchinson, R. C. (2003) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2003.1213624 · Cited by 466
Wearable sensors/systems and their impact on biomedical engineering
Bonato, P. (2003) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2003.1213622 · Cited by 382 · cited 1×
“These devices not only allow long-term, continuous, and unobstructed monitoring of physiologic information, such as biopotential, photoplethysmogram (PPG), heart rate (HR), blood pressure (BP), blood oxygen saturation (SaO2), and respiration, but can also provide more realistic indication of the patient’s health statu…”
Background
Cited by
Smart wearable systems: Current status and future challenges
Chan, M., Estève, D., Fourniols, J.-Y., Escriba, C., & Campo, E. (2012) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2012.09.003 · Cited by 953
Foot Plantar Pressure Measurement System: A Review
Abdul Razak, A. H., Zayegh, A., Begg, R. K., & Wahab, Y. (2012) · Sensors · doi:10.3390/s120709884 · Cited by 817
Recent advances in cortisol sensing technologies for point-of-care application
Kaushik, A., Vasudev, A., Arya, S. K., Pasha, S. K., & Bhansali, S. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.09.060 · Cited by 316
Securing internet of medical things systems: limitations, issues and recommendations
Yaacoub, J.-P. A., Noura, M., Noura, H. N., Salman, O., Yaacoub, E., Couturier, R., & Chehab, A. (2020) · Future Generation Computer Systems · doi:10.1016/j.future.2019.12.028 · Cited by 308
Federated learning for secure IoMT-applications in smart healthcare systems: A comprehensive review
Rani, S., Kataria, A., Kumar, S., & Tiwari, P. (2023) · Knowledge-Based Systems · doi:10.1016/j.knosys.2023.110658 · Cited by 228
Metadata
- Authors
- Hung, K., Zhang, Y. T., & Tai, B.
- Venue
- The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Publisher
- IEEE
- Published
- 2005-03-21
- Volume
- 4
- Pages
- 5384-5387
- OpenAlex
- W2345580596
- Cited by
- 206
- References
- 2
- FWCI
- 17.86
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Wearable medical devices for tele-home healthcare. https://app.cochat.ai/papers/10.1109/iembs.2004.1404503
- The paper
- Hung, K., Zhang, Y. T., & Tai, B. (2005). Wearable medical devices for tele-home healthcare. The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. https://doi.org/10.1109/iembs.2004.1404503
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.