Wearable medical devices for tele-home healthcare
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
The world's ageing population and prevalence of chronic diseases have lead to high demand for tele-home healthcare, in which vital-signs monitoring is essential. An overview of state-of-art wearable technologies for remote patient-monitoring is presented, followed by case studies on a cuffless blood pressure meter, ring-type heart rate monitor, and Bluetoothtrade mark-based ECG monitor. Aim of our project is to develop a tele-home healthcare system which utilizes wearable devices, wireless communication technologies, and multisensor data fusion methods. As an important part of this system, a cuffless BP meter has been developed and tested on 30 subjects in a total of 71 trials over a period of five months. Preliminary results show a mean error (ME) of 1.82 mmHg and standard deviation of error (SDE) of 7.62 mmHg in systolic pressure; while ME and SDE in diastolic pressure are 0.45 mmHg and 5.27 mmHg, respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Enhancing the quality of life through wearable technology
Park, S., & Jayaraman, S. (2003) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2003.1213625 · Cited by 614 · cited 1×
“For example, the Georgia Tech Wearable Motherboard, which is a vest with plastic optical fibers and other specialty fibers woven throughout its fabric, has an architecture that allows connection to vital signs sensors positioned on different body locations [10].”
BackgroundMobile monitoring with wearable photoplethysmographic biosensors
Asada, H. H., Shaltis, P., Reisner, A., Rhee, S., & Hutchinson, R. C. (2003) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2003.1213624 · Cited by 466
Wearable sensors/systems and their impact on biomedical engineering
Bonato, P. (2003) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2003.1213622 · Cited by 382 · cited 1×
“These devices not only allow long-term, continuous, and unobstructed monitoring of physiologic information, such as biopotential, photoplethysmogram (PPG), heart rate (HR), blood pressure (BP), blood oxygen saturation (SaO2), and respiration, but can also provide more realistic indication of the patient’s health statu…”
BackgroundStress monitoring using a distributed wireless intelligent sensor system
Jovanov, E., O'Donnell Lords, A., Raskovic, D., Cox, P. G., Adhami, R., & Andrasik, F. (2003) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2003.1213626 · Cited by 373 · cited 1×
“in usage of intelligent sensors in heart rate variability studies, electrocardiogram (ECG) monitoring, and physical rehabilitation [7-9].”
BackgroundImplementation of a WAP-based telemedicine system for patient monitoring
Hung, K., & Zhang, Y.-T. (2003) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2003.811870 · Cited by 290
Self-citationWearable sensor badge and sensor jacket for context awareness
Farringdon, J., Moore, A. J., Tilbury, N., Church, J., & Biemond, P. D. (2003) · Digest of Papers. Third International Symposium on Wearable Computers · doi:10.1109/iswc.1999.806681 · Cited by 239 · cited 1×
“Other miniature, wearable items, such as wireless and battery-less stethoscope, necklace, and badge have also been proposed for acquisitions of bioacoustic signals, blood flow, and position / movement, respectively [16-18].”
BackgroundMartin, T., Jovanov, E., & Raskovic, D. (2002) · Digest of Papers. Fourth International Symposium on Wearable Computers · doi:10.1109/iswc.2000.888463 · Cited by 234 · cited 1×
“in usage of intelligent sensors in heart rate variability studies, electrocardiogram (ECG) monitoring, and physical rehabilitation [7-9].”
BackgroundELECTROACTIVE FABRICS AND WEARABLE BIOMONITORING DEVICES
Rossi, D. D., Carpi, F., Lorussi, F., Mazzoldi, A., Paradiso, R., Pasquale Scilingo, E., & Tognetti, A. (2003) · AUTEX Research Journal · doi:10.1515/aut-2003-030404 · Cited by 160 · cited 1×
“It has been shown that conductive textiles and piezo-resistive fabric can be integrated into shirts to measure patient movements, peripheral pulse, respiration, and biopotentials [13-14].”
BackgroundPredicting the potential of wearable technology
Binkley, P. F., Frontera, W., Standaert, D. G., & Stein, J. (2003) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2003.1213623 · Cited by 132 · cited 1×
“These devices not only allow long-term, continuous, and unobstructed monitoring of physiologic information, such as biopotential, photoplethysmogram (PPG), heart rate (HR), blood pressure (BP), blood oxygen saturation (SaO2), and respiration, but can also provide more realistic indication of the patient’s health statu…”
BackgroundWireless house calls: using communications technology for health care and monitoring
Boric-Lubeke, O., & Lubecke, V. M. (2002) · IEEE Microwave Magazine · doi:10.1109/mmw.2002.1028361 · Cited by 116 · cited 1×
“These devices not only allow long-term, continuous, and unobstructed monitoring of physiologic information, such as biopotential, photoplethysmogram (PPG), heart rate (HR), blood pressure (BP), blood oxygen saturation (SaO2), and respiration, but can also provide more realistic indication of the patient’s health statu…”
Background
Cited by
Smart wearable systems: Current status and future challenges
Chan, M., Estève, D., Fourniols, J.-Y., Escriba, C., & Campo, E. (2012) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2012.09.003 · Cited by 953
Foot Plantar Pressure Measurement System: A Review
Abdul Razak, A. H., Zayegh, A., Begg, R. K., & Wahab, Y. (2012) · Sensors · doi:10.3390/s120709884 · Cited by 817
Recent advances in cortisol sensing technologies for point-of-care application
Kaushik, A., Vasudev, A., Arya, S. K., Pasha, S. K., & Bhansali, S. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.09.060 · Cited by 316
“Portable miniaturized analytical devices for disease detection at early stages and for monitoring physiological variables at POC could be useful to personalize health diagnostics for appropriate effectual and exact treatment (Glaros and Fotiadis, 2005; Hung et al., 2004; Turner, 2013).”
BackgroundSecuring internet of medical things systems: limitations, issues and recommendations
Yaacoub, J.-P. A., Noura, M., Noura, H. N., Salman, O., Yaacoub, E., Couturier, R., & Chehab, A. (2020) · Future Generation Computer Systems · doi:10.1016/j.future.2019.12.028 · Cited by 308
“provided by a health care professional, and rely on simple technologies (e-mail, the Internet, smart medical devices) to communicate with the hospital [60].”
BackgroundTsai, T.-H., Lin, W.-Y., Chang, Y.-S., Chang, P.-C., & Lee, M.-Y. (2020) · PLOS ONE · doi:10.1371/journal.pone.0227270 · Cited by 262
Federated learning for secure IoMT-applications in smart healthcare systems: A comprehensive review
Rani, S., Kataria, A., Kumar, S., & Tiwari, P. (2023) · Knowledge-Based Systems · doi:10.1016/j.knosys.2023.110658 · Cited by 228
Computational Health Informatics in the Big Data Age: A Survey
Fang, R., Pouyanfar, S., Yang, Y., Chen, S.-C., & Iyengar, S. S. (2017) · ACM Computing Surveys · doi:10.1145/2932707 · Cited by 210
Industrial wearable system: the human-centric empowering technology in Industry 4.0
Kong, X. T. R., Luo, H., Huang, G. Q., & Yang, X. (2019) · Journal of Intelligent Manufacturing · doi:10.1007/s10845-018-1416-9 · Cited by 209
“In industrial applications, user requirements of up to eight hours of use without recharging are common (Hung et al. 2004; Anastasi et al. 2009).”
BackgroundAn implementation of IoT for healthcare
Kodali, R. K., Swamy, G., & Lakshmi, B. (2015) · 2015 IEEE Recent Advances in Intelligent Computational Systems (RAICS) · doi:10.1109/raics.2015.7488451 · Cited by 195
Marques, G., Pitarma, R., M. Garcia, N., & Pombo, N. (2019) · Electronics · doi:10.3390/electronics8101081 · Cited by 181
“A tele-home medical solution that incorporates wearables, wireless technologies, and sensor data fusion techniques was presented by [75].”
MethodDeep Learning Intervention for Health Care Challenges: Some Biomedical Domain Considerations
Tobore, I., Li, J., Yuhang, L., Al-Handarish, Y., Kandwal, A., Nie, Z., & Wang, L. (2019) · JMIR mHealth and uHealth · doi:10.2196/11966 · Cited by 180
Review and Reappraisal of Smart Clothing
Cho, G., Lee, S., & Cho, J. (2009) · International Journal of Human-Computer Interaction · doi:10.1080/10447310902997744 · Cited by 93
Metadata
- Authors
- Hung, K., Zhang, Y. T., & Tai, B.
- Venue
- The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Publisher
- IEEE
- Published
- 2005-03-21
- Volume
- 4
- Pages
- 5384-5387
- OpenAlex
- W2345580596
- Cited by
- 206
- References
- 13
- FWCI
- 17.86
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.