In vivo and In vitro Differences in the Charge-injection and Electrochemical Properties of Iridium Oxide Electrodes
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
The electrochemical response of activated iridium oxide (AIROF) electrodes implanted acutely in the subretinal space of the rabbit is compared with in vitro measurements in model electrolytes. Voltage transients during current pulsing, cyclic voltammetry, impedance spectroscopy and open-circuit potential measurements were compared. Subretinal charge injection by constant current pulsing required significantly greater driving voltages due to both higher access resistances (iR) and large electrochemical polarization across the electrode-tissue interface. Differences in the in vivo and in vitro open-circuit potentials were also noted. The data suggest that the buffering capacity in the subretinal space, at least in the acute study, is higher than that in inorganic models of interstitial fluid. Possible origins of these differences in terms of electrode-tissue interactions are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The electrical conductivity of human cerebrospinal fluid at body temperature
Baumann, S. B., Wozny, D. R., Kelly, S. K., & Meno, F. M. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.554770 · Cited by 494
Cogan, S. F., Troyk, P. R., Ehrlich, J., & Plante, T. D. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.851503 · Cited by 162 · cited 1×
“Ag|AgCl), a pulse width (PW) of 0.4 ms, and a frequency of 50 Hz [ 1 ].”
Self-citationCogan, S. F., Troyk, P. R., Ehrlich, J., Plante, T. D., & Detlefsen, D. E. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.862572 · Cited by 138 · cited 1×
“In vitro, the optimum bias is about 0.6 V vs. Ag|AgCl, although it is necessary to employ asymmetric current pulses or other strategies to limit the positive potential excursion during the charge balancing anodal phase to avoid water oxidation [ 2 ].”
Self-citation
Cited by
In Vitro and In Vivo Evaluation of PEDOT Microelectrodes for Neural Stimulation and Recording
Venkatraman, S., Hendricks, J., King, Z. A., Sereno, A. J., Richardson-Burns, S., Martin, D., & Carmena, J. M. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2109399 · Cited by 319
“to glial scar formation around the electrodes [32] and the nature of the in vivo electrolyte [33].”
BackgroundBrunton, E. K., Winther-Jensen, B., Wang, C., Yan, E. B., Hagh Gooie, S., Lowery, A. J., & Rajan, R. (2015) · Frontiers in Neuroscience · doi:10.3389/fnins.2015.00265 · Cited by 46
From softening polymers to multimaterial based bioelectronic devices
Ecker, M., Joshi-Imre, A., Modi, R., Frewin, C. L., Garcia-Sandoval, A., Maeng, J., Gutierrez-Heredia, G., Pancrazio, J. J., & Voit, W. E. (2019) · Multifunctional Materials · doi:10.1088/2399-7532/aaed58 · Cited by 34
Metadata
- Authors
- Cogan, S. F.
- Venue
- 2006 International Conference of the IEEE Engineering in Medicine and Biology Society
- Publisher
- IEEE
- Published
- 2006-08
- Volume
- 2006
- Pages
- 882-885
- OpenAlex
- W2149137369
- Cited by
- 55
- References
- 3
- FWCI
- 11.08
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.