Comparison of Heart Rate Variability Signal Features Derived from Electrocardiography and Photoplethysmography in Healthy Individuals
Abstract
The heart rate variability (HRV) signal is indicative of autonomic regulation of the heart rate (HR). It could be used as a noninvasive marker in monitoring the physiological state of an individual. Currently, the primary method of deriving the HRV signal is to acquire the electrocardiogram (ECG) signal, apply appropriate QRS detection algorithms to locate the R wave and its peak, find the RR intervals, and perform suitable interpolation and resampling to produce a uniformly sampled tachogram. This process could sometimes result in errors in the HRV signal due to drift, electromagnetic and biologic interference, and the complex morphology of the ECG signal. The photoplethysmographic (PPG) signal has the potential to eliminate the problems with the ECG signal to derive the HRV signal. To investigate this point, a PDA-based system was developed to simultaneously record ECG and PPG signals to facilitate accurately controlled sampling and recording durations. Two healthy young volunteers participated in this pilot study to evaluate the applicability of our approach. To improve data quality, ECG and PPG recordings were acquired three times/subject. A comparison between different features of the HRV signals derived from both methods was performed to test the validity of using PPG signals in HRV analysis. We used autoregressive (AR) modeling, Poincare' plots, cross correlation, standard deviation, arithmetic mean, skewness, kurtosis, and approximate entropy (ApEn) to derive and compare different measures from both ECG and PPG signals. This study demonstrated that our PDA-based system was a convenient and reliable means for acquisition of PPG-derived and ECG-derived HRV signals. The excellent agreement between different measures of HRV signals acquired from both methods provides potential support for the idea of using PPGs instead of ECGs in HRV signal derivation and analysis in ambulatory cardiac monitoring of healthy individuals.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Heart rate variability: Standards of measurement, physiological interpretation, and clinical use
Malik, M., Bigger, J. T., Camm, A. J., Kleiger, R. E., Malliani, A., Moss, A. J., & Schwartz, P. J. (1996) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a014868 · Cited by 15,289
Cited by
Ghamari, M. (2018) · International Journal of Biosensors & Bioelectronics · doi:10.15406/ijbsbe.2018.04.00125 · Cited by 945
How accurate is pulse rate variability as an estimate of heart rate variability?
Schäfer, A., & Vagedes, J. (2013) · International Journal of Cardiology · doi:10.1016/j.ijcard.2012.03.119 · Cited by 661
Selvaraj, N., Jaryal, A., Santhosh, J., Deepak, K. K., & Anand, S. (2008) · Journal of Medical Engineering & Technology · doi:10.1080/03091900701781317 · Cited by 342
Lu, G., Yang, F., Taylor, J. A., & Stein, J. F. (2009) · Journal of Medical Engineering & Technology · doi:10.3109/03091900903150998 · Cited by 324
Li, K., Cardoso, C., Moctezuma-Ramirez, A., Elgalad, A., & Perin, E. (2023) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph20247146 · Cited by 160
Metadata
- Authors
- Bolanos, M., Nazeran, H., & Haltiwanger, E.
- Venue
- 2006 International Conference of the IEEE Engineering in Medicine and Biology Society
- Publisher
- IEEE
- Published
- 2006-08
- Volume
- 2006
- Pages
- 4289-4294
- OpenAlex
- W2155520195
- Cited by
- 172
- References
- 1
- FWCI
- 7.41
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of Heart Rate Variability Signal Features Derived from Electrocardiography and Photoplethysmography in Healthy Individuals. https://app.cochat.ai/papers/10.1109/iembs.2006.260607
- The paper
- Bolanos, M., Nazeran, H., & Haltiwanger, E. (2006). Comparison of Heart Rate Variability Signal Features Derived from Electrocardiography and Photoplethysmography in Healthy Individuals. 2006 International Conference of the IEEE Engineering in Medicine and Biology Society. https://doi.org/10.1109/iembs.2006.260607
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.