Assessment of heart rate variability derived from finger-tip photoplethysmography as compared to electrocardiography
Abstract
Heart rate variability (HRV) is traditionally derived from RR interval time series of electrocardiography (ECG). Photoplethysmography (PPG) also reflects the cardiac rhythm since the mechanical activity of the heart is coupled to its electrical activity. Thus, theoretically, PPG can be used for determining the interval between successive heartbeats and heart rate variability. However, the PPG wave lags behind the ECG signal by the time required for transmission of pulse wave. In this study, finger-tip PPG and standard lead II ECG were recorded for five minutes from 10 healthy subjects at rest. The results showed a high correlation (median = 0.97) between the ECG-derived RR intervals and PPG-derived peak-to-peak (PP) intervals. PP variability was accurate (0.1 ms) as compared to RR variability. The time domain, frequency domain and Poincaré plot HRV parameters computed using RR interval method and PP interval method showed no significant differences (p < 0.05). The error analysis also showed insignificant differences between the HRV indices obtained by the two methods. Bland-Altman analysis showed high degree of agreement between the two methods for all the parameters of HRV. Thus, HRV can also be reliably estimated from the PPG based PP interval method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Heart Rate Variability: Standards of Measurement, Physiological Interpretation, and Clinical Use
Electrophysiology, T. F. O. T. E. S. O. C. T. N. A. (1996) · Circulation · doi:10.1161/01.cir.93.5.1043 · Cited by 17,159
Heart rate variability: Standards of measurement, physiological interpretation, and clinical use
Malik, M., Bigger, J. T., Camm, A. J., Kleiger, R. E., Malliani, A., Moss, A. J., & Schwartz, P. J. (1996) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a014868 · Cited by 15,289
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967
Nitzan, M., Babchenko, A., Khanokh, B., & Landau, D. (1998) · Physiological Measurement · doi:10.1088/0967-3334/19/1/008 · Cited by 217
Bolanos, M., Nazeran, H., & Haltiwanger, E. (2006) · 2006 International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2006.260607 · Cited by 172
Relation between heart rate and pulse transit time during paced respiration
Drinnan, M. J., Allen, J., & Murray, A. (2001) · Physiological Measurement · doi:10.1088/0967-3334/22/3/301 · Cited by 167
Autonomic Control of Skin Microvessels: Assessment by Power Spectrum of Photoplethysmographic Waves
Bernardi, L., Radaelli, A., Soldà, P. L., Coats, A. J. S., REEDER, M. K., Calciati, A., Garrard, C. S., & Sleight, P. (1996) · Clinical Science · doi:10.1042/cs0900345 · Cited by 147
Piskorski, J., & Guzik, P. (2005) · Computational Methods in Science and Technology · doi:10.12921/cmst.2005.11.01.39-48 · Cited by 144
Comparison of finger plethysmograph to ECG in the measurement of heart rate variability
Giardino, N. D., Lehrer, P. M., & Edelberg, R. (2002) · Psychophysiology · doi:10.1111/1469-8986.3920246 · Cited by 136
Deriving heart period variability from blood pressure waveforms
McKinley, P. S., Shapiro, P. A., Bagiella, E., Myers, M. M., Meersman, R. E. D., Grant, I., & Sloan, R. P. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01110.2002 · Cited by 61
Cited by
How accurate is pulse rate variability as an estimate of heart rate variability?
Schäfer, A., & Vagedes, J. (2013) · International Journal of Cardiology · doi:10.1016/j.ijcard.2012.03.119 · Cited by 661
Gil, E., Orini, M., Bailón, R., Vergara, J. M., Mainardi, L., & Laguna, P. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/9/015 · Cited by 461
Lu, G., Yang, F., Taylor, J. A., & Stein, J. F. (2009) · Journal of Medical Engineering & Technology · doi:10.3109/03091900903150998 · Cited by 324
Can Wearable Devices Accurately Measure Heart Rate Variability? A Systematic Review
Georgiou, K., Larentzakis, A. V., Khamis, N. N., Alsuhaibani, G. I., Alaska, Y. A., & Giallafos, E. J. (2018) · Folia Medica · doi:10.2478/folmed-2018-0012 · Cited by 244
HeartPy: A novel heart rate algorithm for the analysis of noisy signals
van Gent, P., Farah, H., van Nes, N., & van Arem, B. (2019) · Transportation Research Part F: Traffic Psychology and Behaviour · doi:10.1016/j.trf.2019.09.015 · Cited by 234
Metadata
- Authors
- Selvaraj, N., Jaryal, A., Santhosh, J., Deepak, K. K., & Anand, S.
- Venue
- Journal of Medical Engineering & Technology
- Publisher
- Informa UK Limited
- Published
- 2008-01
- Volume
- 32
- Issue
- 6
- Pages
- 479-484
- ISSN
- 0309-1902 (ISSN-L)
- 1464-522X
- OpenAlex
- W2037549735
- Cited by
- 342
- References
- 18
- FWCI
- 4.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Assessment of heart rate variability derived from finger-tip photoplethysmography as compared to electrocardiography. https://app.cochat.ai/papers/10.1080/03091900701781317
- The paper
- Selvaraj, N., Jaryal, A., Santhosh, J., Deepak, K. K., & Anand, S. (2008). Assessment of heart rate variability derived from finger-tip photoplethysmography as compared to electrocardiography. Journal of Medical Engineering & Technology. https://doi.org/10.1080/03091900701781317
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.