Electrochemical Properties of Platinum Electrodes in Vitro: Comparison of Six Different Surface Qualities
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Platinum serves as electrode material since several decades because of its excellent corrosion resistance and acceptable phase boundary impedance and charge injection capacity. Here, we investigate how the electrochemical performance of platinum is improved by different methods of surface roughening. By using a small signal model, it was calculated that - depending on the surface treatment - the effective electrode surface can be enlarged by a factor of 76. However, pulse tests indicate for the identical electrode treatment an increase in charge injection capacitance by a factor of only 11.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
In vitro electrical properties for iridium oxide versus titanium nitride stimulating electrodes
Weiland, J. D., Anderson, D. J., & Humayun, M. S. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2002.805487 · Cited by 382 · cited 1×
“[4], who applied pulses of the same shape (although different amplitude), the capacitance density Cd for iridium oxide (5250 μF/cm2) and for titanium nitride (1050 μF/cm2) can be calculated, which is 10 times and 2 times, respectively, larger than that of the roughest platinum in this study.”
Background
Cited by
Organic electrode coatings for next-generation neural interfaces
Aregueta-Robles, U. A., Woolley, A. J., Poole-Warren, L. A., Lovell, N. H., & Green, R. A. (2014) · Frontiers in Neuroengineering · doi:10.3389/fneng.2014.00015 · Cited by 254
Nanostructured platinum grass enables superior impedance reduction for neural microelectrodes
Boehler, C., Stieglitz, T., & Asplund, M. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2015.07.036 · Cited by 179
“Pulse durations were chosen according to previously repor t d values for evaluation of the electrochemical properties of neural electrodes [29, 30].”
MethodIntegrated circuit amplifiers for multi-electrode intracortical recording
Jochum, T., Denison, T., & Wolf, P. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/1/012001 · Cited by 167
Focal activation of the feline retina via a suprachoroidal electrode array
Wong, Y. T., Chen, S. C., Seo, J. M., Morley, J. W., Lovell, N. H., & Suaning, G. J. (2009) · Vision Research · doi:10.1016/j.visres.2009.02.018 · Cited by 109
Foldes, E. L., Ackermann, D. M., Bhadra, N., Kilgore, K. L., & Bhadra, N. (2011) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2010.12.020 · Cited by 61
“Per typical practice (de Boer and van Oosterom, 1978;Schuettler, 2007;Cogan, 2008), the impedance magnitude measurements were used to estimate the ohmic resistance of the solution between the test and reference electrodes, RΩ, and the charge transfer resistance due to transfer of charges at the…”
BackgroundMethodResultInfluential
Metadata
- Authors
- Schuettler, M.
- Venue
- 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Publisher
- IEEE
- Published
- 2007-08
- Volume
- 2007
- Pages
- 186-189
- ISSN
- 1557-170X (ISSN-L)
- OpenAlex
- W2149719238
- Cited by
- 37
- References
- 1
- FWCI
- 3.52
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electrochemical Properties of Platinum Electrodes in Vitro: Comparison of Six Different Surface Qualities. https://app.cochat.ai/papers/10.1109/iembs.2007.4352254
- The paper
- Schuettler, M. (2007). Electrochemical Properties of Platinum Electrodes in Vitro: Comparison of Six Different Surface Qualities. 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. https://doi.org/10.1109/iembs.2007.4352254
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.