Low Variance Adaptive Filter for Cancelling Motion Artifact in Wearable Photoplethysmogram Sensor Signals
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
The photoplethysmogram (PPG) is an extremely useful wearable sensing medical diagnostic tool. However, the PPG signal becomes highly corrupted and unusable when the sensor wearer is in motion. This paper investigates how confidently Widrow's Adaptive Noise Cancellation can eliminate motion artifact and recover a motion corrupted PPG signal for a wearer engaged in jogging motions. It has previously been shown that Widrow's Adaptive Noise Cancellation can recover a motion corrupted PPG signal for certain data sets by using a collocated accelerometer to measure the corrupting motion. However, wearer motion is band limited, and provides little information for estimating motion-to-PPG noise transfer dynamics. This means that, without proper care, recovery results can be unreliable. In the present work, both Finite Impulse Response (FIR) and Laguerre series black box transfer dynamics models are evaluated for how confidently they can be identified. Model confidence is quantified in terms of variance of the transfer dynamics estimate at the motion frequencies. For typical jogging motion, it is found that standard deviation of the FIR model transfer dynamics is 30% of the mean value at the motion input frequency. The standard deviation of the Laguerre model transfer dynamics is only 1%. Time domain data shows how a Laguerre model outperforms a FIR model in accordance with the computed model variance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Adaptive noise cancelling: Principles and applications
Widrow, B., Glover, J. R., McCool, J. M., Kaunitz, J., Williams, C. S., Hearn, R. H., Zeidler, J. R., Eugene Dong, Jr., & Goodlin, R. C. (1975) · Proceedings of the IEEE · doi:10.1109/proc.1975.10036 · Cited by 3,939 · cited 2×
“Widrow’s Adaptive Noise Cancellation (ANC) [ 4 ] is very appealing for application to cancelling artifact in the PPG because it is capable of removing in-band disturbances and can be rapidly tuned to current sensing conditions if there is sufficient motion excitation.”
BackgroundMobile monitoring with wearable photoplethysmographic biosensors
Asada, H. H., Shaltis, P., Reisner, A., Rhee, S., & Hutchinson, R. C. (2003) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2003.1213624 · Cited by 466
Self-citationArtifact-resistant power-efficient design of finger-ring plethysmographic sensors
Rhee, S., Yang, B.-H., & Asada, H. H. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.930904 · Cited by 235 · cited 2×
“This work evaluates how confidently the transfer dynamics can be identified for a jogger wearing a ring-type PPG sensor [10].”
BackgroundMethodSelf-citationAdaptive reduction of motion artifact in the electrocardiogram
Tong, D. A., Bartels, K. A., & Honeyager, K. S. (2002) · Proceedings of the Second Joint 24th Annual Conference and the Annual Fall Meeting of the Biomedical Engineering Society] [Engineering in Medicine and Biology · doi:10.1109/iembs.2002.1106451 · Cited by 122 · cited 1×
“Widrow’s ANC has been utilized with accelerometer motion reference by the authors’ group [5], [6] and others [7] for motion artifact reduction in PPG sensors, as well as ECG sensors [8],[9].”
Method
Cited by
A review of wearable sensors and systems with application in rehabilitation
Patel, S., Park, H., Bonato, P., Chan, L., & Rodgers, M. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-21 · Cited by 2,396
Wearable photoplethysmographic sensors—past and present
Tamura, T., Maeda, Y., Sekine, M., & Yoshida, M. (2014) · Electronics · doi:10.3390/electronics3020282 · Cited by 912
“Time domain data shows how a Laguerre model outperforms a FIR model in accordance with computed model variance [75].”
MethodHeart rate tracking in photoplethysmography signals affected by motion artifacts: a review
Ismail, S., Akram, U., & Siddiqi, I. (2021) · EURASIP Journal on Advances in Signal Processing · doi:10.1186/s13634-020-00714-2 · Cited by 101
A Review of Methods for Non-Invasive Heart Rate Measurement on Wrist
De Pinho Ferreira, N., Gehin, C., & Massot, B. (2021) · IRBM · doi:10.1016/j.irbm.2020.04.001 · Cited by 49
Couceiro, R., Carvalho, P., Paiva, R. P., Henriques, J., & Muehlsteff, J. (2012) · 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/embc.2012.6346497 · Cited by 33
Metadata
- Authors
- Wood, L. B., & Asada, H. H.
- Venue
- 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Publisher
- IEEE
- Published
- 2007-08
- Volume
- 2007
- Pages
- 652-655
- ISSN
- 1557-170X (ISSN-L)
- OpenAlex
- W2127076760
- Cited by
- 51
- References
- 4
- FWCI
- 5.36
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.