Ultra short term analysis of heart rate variability for monitoring mental stress in mobile settings.
The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
Heart rate variability (HRV) analysis is commonly used as a quantitative marker depicting the activity of autonomous nervous system (ANS) that may be related to mental stress. For mobile applications, short term ECG measurement may be used for HRV analysis since the conventional five minute long recordings might be inadequately long. Short term analysis of HRV features has been investigated mostly in ECG data from normal and cardiac patients. Thus, short term HRV features may not have any relevance on the assessment of acute mental stress. In this study, we obtained ultra short term HRV features from 24 subjects during baseline stage and Stroop color word test. We validated these HRV features by showing significant differences in HRV features existed between the two stages. Our results indicated that ultra short term analysis of heart rate and RR intervals within 10 s, RMSSD and PNN50 within 30 s, HF within 40 s, LF/HF, normalized LF, and normalized HF within 50 s could be reliably performed for monitoring mental stress in mobile settings.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Furthermore recordings between 10 and 50 s, according to which HRV parameters are considered, have been proven to be reliable under certain conditions (Salahuddin et al., 2007).”
From Heart Rate Variability and Cardiac Vagal Tone in Psychophysiological Research – Recommendations for Experiment Planning, Data Analysis, and Data Reporting (2017) · cites this paper as Salahuddin et al., 2007
Citations
Cites
The PHQ-9: Validity of a brief depression severity measure
Kroenke, K., Spitzer, R. L., & Williams, J. B. W. (2001) · Journal of General Internal Medicine · doi:10.1046/j.1525-1497.2001.016009606.x · Cited by 44,910
Heart rate variability: Standards of measurement, physiological interpretation, and clinical use
Malik, M., Bigger, J. T., Camm, A. J., Kleiger, R. E., Malliani, A., Moss, A. J., & Schwartz, P. J. (1996) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a014868 · Cited by 15,289 · cited 2×
“EART Rate Variability (HRV) has been traditionally calculated from five minute or 24 hour ECG recordings for the analysis of cardiac diseases [1].”
Welch, P. (1967) · IEEE Transactions on Audio and Electroacoustics · doi:10.1109/tau.1967.1161901 · Cited by 12,277 · cited 1×
“Frequency domain features were calculated by Welch’s averaging method [23].”
MethodAnterior Cingulate Cortex, Error Detection, and the Online Monitoring of Performance
Carter, C. S., Braver, T. S., Barch, D. M., Botvinick, M. M., Noll, D., & Cohen, J. D. (1998) · Science · doi:10.1126/science.280.5364.747 · Cited by 3,273 · cited 2×
“In addition, it was also widely used in various neurological studies [11-15, 25].”
BackgroundMethodPardo, J. V., Pardo, P. J., Janer, K. W., & Raichle, M. E. (1990) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.87.1.256 · Cited by 1,495 · cited 2×
“In addition, it was also widely used in various neurological studies [11-15, 25].”
BackgroundMethodHuman cingulate cortex and autonomic control: converging neuroimaging and clinical evidence
Critchley, H. D., Mathias, C. J., Josephs, O., O’Doherty, J., Zanini, S., Dewar, B., Cipolotti, L., Shallice, T., & Dolan, R. J. (2003) · Brain · doi:10.1093/brain/awg216 · Cited by 1,201 · cited 2×
“In addition, it was also widely used in various neurological studies [11-15, 25].”
BackgroundMethodThe effect of mental stress on heart rate variability and blood pressure during computer work
Hjortskov, N., Riss�n, D., Blangsted, A. K., Fallentin, N., Lundberg, U., & S�gaard, K. (2004) · European Journal of Applied Physiology · doi:10.1007/s00421-004-1055-z · Cited by 766 · cited 1×
“Mental stress increased sympathetic activity (low frequency HRV) and blood pressure [8] but decreased parasympathetic activity (high frequency HRV) [9, 10].”
BackgroundStressed or Stressed out: What Is the Difference?
McEwen, B. S. (2005) · Journal of Psychiatry and Neuroscience · doi:10.1139/jpn.0540 · Cited by 593 · cited 1×
“The concept of allostasis has been introduced to explain how adaptive processes maintain stability or homeostasis through the production of mediators such as stress hormone, neurotransmitter, and cytokines [7].”
BackgroundForebrain Pathways Mediating Stress-Induced Hormone Secretion
Van de Kar, L. D., & Blair, M. L. (1999) · Frontiers in Neuroendocrinology · doi:10.1006/frne.1998.0172 · Cited by 380 · cited 1×
“In response to stress, the brain activates the secretion of numerous hormones, including corticosterone/cortisol, catecholamine, prolactin, oxytocin, and renin, as a part of the survival mechanism [6].”
BackgroundThe reliability of short-term measurements of heart rate variability
Sandercock, G. R. H., Bromley, P. D., & Brodie, D. A. (2005) · International Journal of Cardiology · doi:10.1016/j.ijcard.2004.09.013 · Cited by 307 · cited 1×
“HRV features sensitive to low frequency components of HRV had poor repeatability and cannot be estimated accurately from ECG segments shorter than 10 min [4].”
Method
Research works printed but not linked: 2
- bayevsky, 2002, HRV Analysis under the usage of different electrocardiography systems (Methodical recommendations)
- s?is?ka, 2002, The Stroop Colour-Word Test in Psychology and Biomedicine, Acta Univ Palacki Olomuc Gymn, 32, 45
Cited by
Items 201–300 of 415
Investigating attentional scope as a novel indicator of emotional state in animals
Hamlaoui, A., Keeling, L. J., Burman, O. H. P., & Verbeek, E. (2022) · Scientific Reports · doi:10.1038/s41598-022-21151-1 · Cited by 9
Sex Parity in Cognitive Fatigue Model Development for Effective Human-Robot Collaboration
Kalatzis, A., Hopko, S. K., Mehta, R. K., Stanley, L., & Wittie, M. P. (2022) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros47612.2022.9981097 · Cited by 10
“Previous research indicates that these metrics can be extracted for the trial windows [28] To extract the ECG signal features, the Q wave, R wave, S wave complex was detected for each trial window and then the time series metric of RR interval data was derived.”
BackgroundOverview of the effect of physiological stress on different biological signals
Gupta, G., Khan, M., Sherwani, K. I. K., & Manaullah, M. (2023) · International Conference on Recent Advances in Electrical, Electronics & Digital Healthcare Technologies (REEDCON) · doi:10.1109/reedcon57544.2023.10150828 · Cited by 10
A study on the stress identification using observed heart beat data
Pramanta, S. P. L. A., Prihatmanto, A. S., & Park, M.-G. (2016) · International Conference on System Engineering and Technology · doi:10.1109/icsengt.2016.7849640 · Cited by 9
Predicting cognitive states from wearable recordings of autonomic function
Webster, E., Sukaviriya, N., Chang, H., & Kozloski, J. (2017) · IBM Journal of Research and Development · doi:10.1147/jrd.2017.2648698 · Cited by 8
Shimmura, M., Uehara, T., Ogata, K., Shigeto, H., Maeda, T., Sakata, A., Yamasaki, R., & Kira, J. (2019) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2019.05.026 · Cited by 8
“However, recent studies have shown that RMSSD and HF are less sensitive to data duration [12] and can be reliably calculated from data that are approximately 30 s in duration [13,14].”
BackgroundSmith, A.-L., Owen, H., & Reynolds, K. J. (2014) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-014-9617-z · Cited by 8
Ultra-Short Entropy for Mental Stress Detection
Castaldo, R., Montesinos, L., & Pecchia, L. (2018) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-981-10-9038-7_53 · Cited by 8
“In fact, some studies have shown that ApEn values for recordings shorter than 3 minutes are considered unreliable [7, 8].”
BackgroundA Mobile System for Investigating the User's Stress Causes in Daily Life
Hwang, C., & Pushp, S. (2018) · ACM International Joint Conference on Pervasive and Ubiquitous Computing (UbiComp) · doi:10.1145/3267305.3267668 · Cited by 9
Wijsman, J. (2014) · doi:10.3990/1.9789036537858 · Cited by 12
“This was indeed found by four authors [10, 59, 104, 141].”
BackgroundInfluentialDivjak, D., Sun, H., & Milin, P. (2023) · Journal of Neurolinguistics · doi:10.1016/j.jneuroling.2023.101177 · Cited by 7
Human Stress Response and Perceived Safety during Encounters with Quadruped Robots
Gupta, R., Shin, H., Norman, E., Stephens, K. K., Lu, N., & Sentis, L. (2024) · IEEE RO-MAN · doi:10.1109/ro-man60168.2024.10731445 · Cited by 9
“HRV is often evaluated over long recordings; however it can be reliably estimated from ultra-short-term and short-term recordings like our study [37, 38].”
BackgroundUnobtrusive monitoring of ECG-derived features during daily smartphone use
Kwon, S., Kang, S., Lee, Y., Yoo, C., & Park, K. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6944738 · Cited by 7
“Because of its sensitiveness for indicating the change of ANS, numerous previous works have studied the technology based on HRV for daily healthcare services including stress analysis, emotion detection, and even sleep quality estimation [1-4].”
BackgroundEvaluation of mental stress using physiological signals
Subhani, A. R., Xia, L., & Malik, A. S. (2011) · doi:10.1109/natpc.2011.6136423 · Cited by 7
“Some studies are not sensing the changes in brain activities during mental stress [1, 19, 20].”
BackgroundUnconstrained Vital Sign Monitoring System Using an Aortic Pulse Wave Sensor
Hagiyama, N., Hirano, H., Mito, A., Soh, Z., Fujita, E., Ogura, Y., KANEKO, S., Nakamura, R., Saeki, N., Kawamoto, M., et al. (2019) · Scientific Reports · doi:10.1038/s41598-019-53808-9 · Cited by 7
xHits: An Automatic Team Performance Metric for VR Police Training
Uhl, J. C., Nguyen, Q., Hill, Y., Murtinger, M., & Tscheligi, M. (2023) · IEEE International Conference on Metrology for eXtended Reality, Artificial Intelligence and Neural Engineering (MetroXRAINE) · doi:10.1109/metroxraine58569.2023.10405600 · Cited by 7
“We calculated the root mean square of successive differences between normal heartbeats (RMSSD), a metric for HRV, as a measure of acute mental stress, which has shown to be a good marker for stress [21].”
MethodMeasuring psychological immersion through cardiovascular response measures in subtitled films
Fernández, C. A. G., & Jankowska, A. M. (2024) · Translation Cognition & Behavior · doi:10.1075/tcb.00090.gon · Cited by 7
Receptive to bad reception: Jerky motion can make persuasive messages more effective
Patel, H., Bayliss, L. C., Ivory, J., Woodard, K., McCarthy, A., & MacDorman, K. F. (2013) · Computers in Human Behavior · doi:10.1016/j.chb.2013.11.012 · Cited by 9
Impact of Water Temperature on Heart Rate Variability during Bathing
Xu, J., & Chen, W. (2021) · Life · doi:10.3390/life11050378 · Cited by 7
Automated and precise heartbeat detection in ballistocardiography signals using bidirectional LSTM
Zhang, S., Zhang, H., Lin, Z., & Ng, S. H. (2022) · Franklin Open · doi:10.1016/j.fraope.2022.05.001 · Cited by 7
Mental stress classification during a motor task in older adults using an artificial neural network
Kalatzis, A., Stanley, L., Karthikeyan, R., & Mehta, R. K. (2020) · ACM International Joint Conference on Pervasive and Ubiquitous Computing (UbiComp) · doi:10.1145/3410530.3414360 · Cited by 7
“(2007) indicates that both time domain and frequency domain features can be extracted in a 60 seconds window [22].”
BackgroundImpact of signal length and window size on heart rate variability and pulse rate variability metrics
Uryga, A., Olszewski, B., Pietroń, D., & Kasprowicz, M. (2025) · Physiological Measurement · doi:10.1088/1361-6579/adece2 · Cited by 6
“In previous studies, 60 R peaks (36–60 s)-based LF/HF and LFn had no significant differences from 2000 R peaks-based LF/HF and LFn using either the Welch or Lomb–Scargle algorithm (Salahuddin et al 2007, Chou et al 2021).”
Тащук, В. К., Tashchuk, M. V., & Іванчук, П. Р. (2019) · Clinical & experimental pathology · doi:10.24061/1727-4338.xviii.2.68.2019.14 · Cited by 6
Politi, K., Kaminer, K., & Nussinovitch, U. (2019) · Journal of Investigative Medicine · doi:10.1136/jim-2019-001106 · Cited by 6
Li, Q., Qiao, F., McCreight, C., Mao, A., & Zhang, K. (2020) · International Journal of Civil Engineering · doi:10.1007/s40999-020-00497-5 · Cited by 7
Interactive Effects of HRV and P-QRS-T on the Power Density Spectra of ECG Signals
Xiang, T., Ji, N., Clifton, D. A., Lü, L., & Zhang, Y. (2021) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2021.3100425 · Cited by 6
Taniguchi, K., Jinno, N., Seiyama, A., & Shimouchi, A. (2024) · Health Science Reports · doi:10.1002/hsr2.1916 · Cited by 6
“26 The method was based on a maximal entropy combined with the least square method and was useful for frequency analyses using small sample size data.”
MethodComplexity of autonomic control during cerebrovascular reactivity
Intharakham, K., & Suwanprasert, K. (2013) · Biomedical Engineering International Conference · doi:10.1109/bmeicon.2013.6687679 · Cited by 6
“Ultra analysis was performed [11] using Variability Analysis Software, dical Imaging Group (BSAMIG), iversity of Kuopio, FINLAND).”
MethodEffect of Daily Stress on Heart-Rate Variability during Stroop Color Word Task
Park, S., Yu, J., Kang, S., Lee, H., & Dong, S.-Y. (2020) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc44109.2020.9176448 · Cited by 6
“Mental stress can be induced by cognitive tasks such as a Stroop Color Word Task (SCWT) [5-7].”
MethodReliability of ultra‐short indices for autonomic dysfunction in dyslipidemia
Nussinovitch, U. (2020) · Clinical Physiology and Functional Imaging · doi:10.1111/cpf.12661 · Cited by 6
Behavioral and Biological Indicators of Risk and Well-Being in a Sample of South African Youth
Beranbaum, S., Kouri, N. A., der Merwe, N. V., Khedari-DePierro, V., & D'Andrea, W. M. (2022) · Journal of Child & Adolescent Trauma · doi:10.1007/s40653-021-00426-1 · Cited by 9
“While the conventional short-term heart rate recording length is five minutes (Task Force of the European Society of Cardiology & The North American Society of Pacing & Electrophysiology 1996), researchers have demonstrated the feasibility of ultra-short-term recording periods from 60 seconds (Salahuddin et al., 2007)…”
BackgroundAssessment of soundscapes using self-report and physiological measures
Durbridge, S. E., & Murphy, D. T. (2023) · Acta Acustica · doi:10.1051/aacus/2022059 · Cited by 8
SenseMyHeart: A cloud service and API for wearable heart monitors
Silva, P. M. P., & Cunha, J. P. S. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7319511 · Cited by 6
Kennedy-Metz, L. R., & Parker, S. H. (2018) · Journal of Healthcare Informatics Research · doi:10.1007/s41666-018-0016-y · Cited by 7
“Of the timedomain measures, RMSSD is the most appropriate and consistent in detecting differences in mental stress and arousal [8, 41, 45].”
BackgroundGaris, G., Dettmers, C., Hildebrandt, A., Duning, T., & Hildebrandt, H. (2023) · Neurological Sciences · doi:10.1007/s10072-023-07042-x · Cited by 6
LSTS: Periodicity Learning via Long Short-Term Temporal Shift for Remote Physiological Measurement
Jiang, T., Ma, Y., Li, J., Dong, Q., Ji, X., & Liu, Y. (2025) · IEEE Transactions on Circuits and Systems for Video Technology · doi:10.1109/tcsvt.2025.3538474 · Cited by 10
Differential Physiological Responses to Proxemic and Facial Threats in Virtual Avatar Interactions
Nierula, B., Lafci, M. T., Melnik, A., Akgül, M., Siewe, F. T., & Bosse, S. (2025) · IEEE International Symposium on Mixed and Augmented Reality Adjunct (ISMAR-Adjunct) · doi:10.1109/ismar-adjunct68609.2025.00036 · Cited by 5
“While RMSSD is recommended for ≥ 10 seconds [34, 35, 24], phase-specific analysis was necessary given distinct trial phases.”
Hernandez, R., Schneider, S., de Vries, H., Fanning, J. T., Ehrmann, D., Jin, H., Moore, R. C., Juengst, S. B., Striegel, A., Ginsberg, J. P., et al. (2025) · Sensors · doi:10.3390/s25237147 · Cited by 7
“One way it is commonly assessed is with HRV recordings taken for one-to-five minute periods after waking, using technologies such as a chest strap or smartphone camera [22,29].”
Evaluating Just-In-Time Vibrotactile Feedback for Communication Anxiety
Raether, J., Nirjhar, E. H., & Chaspari, T. (2022) · INTERNATIONAL CONFERENCE ON MULTIMODAL INTERACTION · doi:10.1145/3536221.3556590 · Cited by 5
Agostinelli, P. J., Bordonie, N. C., Linder, B. A., Robbins, A. M., Jones, P. L., Reagan, L. F., Mobley, C. B., Miller, M. W., Murrah, W. M., & Sefton, J. M. (2024) · European Journal of Applied Physiology · doi:10.1007/s00421-024-05650-9 · Cited by 6
“These measures were chosen based on their relevance and validity during short-term HRV measurement (4–6 min) (Baek et al. 2015; Cardiology & Electrophysi-ology, 1996; Salahuddin et al. 2007; Shaffer & Ginsberg 2017; F. Shaffer et al. 2014a, b).”
Normahani, P., Makwana, N., von Rosenberg, W., Syed, S., Mandic, D. P., Goverdovsky, V., Standfield, N. J., & Jaffer, U. (2018) · Patient Safety in Surgery · doi:10.1186/s13037-018-0153-5 · Cited by 5
Mental Stress Assessment via Ultra-Short-Term Recordings of Photoplethysmographic Sensor
Zubair, M., & Yoon, C. (2019) · International Conference on Computing, Communication and Security (ICCCS) · doi:10.1109/cccs.2019.8888131 · Cited by 6
“[26] 24 ECG SCWT 10-150 sec 2 Mean RR, Mean HR, STDRR, CV, RMSSD, pNN50, TINN, HRV index, SI, VLF, LF, HF, LF/HF, HFnu, LFnu”
Takada, M., Ebara, T., Sakai, Y., & Kuwano, Y. (2009) · PubMed · Cited by 5
Park, J., Kim, J., & Kim, S.-P. (2018) · Scholarworks@UNIST (Ulsan National Institute of Science and Technology) · Cited by 10
A Personalised Case-Based Stress Diagnosis System Using Physiological Sensor Signals
Begum, S. (2011) · DiVA (Mälardalen University College) · Cited by 5
Do goats recognise humans cross-modally?
Mason, M. A., Semple, S., Marshall, H. H., & McElligott, A. G. (2025) · PeerJ · doi:10.7717/peerj.18786 · Cited by 4
In-vehicle multi-sensory experiences can reduce mental stress
Wang, J., Lim, C., Nasir, M., Nestorowich, J., Berry, C., Ray, P., Pitts, B. J., & Yu, D. (2025) · Applied Ergonomics · doi:10.1016/j.apergo.2025.104592 · Cited by 5
Effects of electrocardiographic noise on ultra-short term Heart Rate Variability indices
Raimondi, A., Busacca, A., Giaconia, G. C., Antonacci, Y., Stivala, S. S., Faes, L., & Pernice, R. (2025) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2025.110803 · Cited by 6
Săvulescu-Fiedler, I., Bucurica, S., Toader, I., Pistol, C., & Maniu, I. (2025) · Physiological Reports · doi:10.14814/phy2.70589 · Cited by 4
“Recording of all the spectral bands that comprise the TP band is done for 5 min (Salahuddin et al., 2007; Shaffer & Ginsberg, 2017; Umetani et al., 1998).”
GuideAI: A Real-time Personalized Learning Solution with Adaptive Interventions
Shukla, A., Bajpai, S., Modi, C., & Siddharth, S. (2026) · ACM International Conference on Intelligent User Interfaces (IUI) · doi:10.1145/3742413.3789125 · Cited by 6
“The pNN50 value measures the percentage of successive RR intervals differing by more than 50 milliseconds, with thresholds indicating stress levels: <20 (high), 20-50 (moderate), >50 (low stress) [46, 59].”
Detection of sympathoadrenal discharge by parameterisation of skin conductance and ECG measurement
Tronstad, C., Elvebakk, O., Kalvøy, H., Bjørgaas, M. R., & Martinsen, Ø. G. (2017) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2017.8037732 · Cited by 6
“Several solutions and devices for non-invasive stress monitoring using SC [4-6], ECG [7,8], or combinations thereof [9] have already been introduced.”
MethodEffect of Odia and Tamil Music on the ANS and the Conduction Pathway of Heart of Odia Volunteers
Nayak, S. K., Srivastava, U., Tibarewala, D. N., Thakur, G., Mohapatra, B., & Pal, K. (2016) · Advances in medical technologies and clinical practice book series · doi:10.4018/978-1-5225-0536-5.ch012 · Cited by 4
Multimodal user state and trait recognition: an overview
Schuller, B. W. (2018) · ACM eBooks · doi:10.1145/3107990.3107997 · Cited by 7
Bibbo, D., Moses, M. J., Gallina, B., & Carli, M. (2022) · Electronics · doi:10.3390/electronics11244074 · Cited by 4
Lin, L., Cheng, Y., Huang, P., Zhang, J., Zheng, J., & Pan, X. (2024) · CNS Neuroscience & Therapeutics · doi:10.1111/cns.14571 · Cited by 4
Roovers, T., Habibović, M., Lodder, P., Widdershoven, J. W. M. G., & Kop, W. J. (2024) · IJC Heart & Vasculature · doi:10.1016/j.ijcha.2024.101563 · Cited by 5
Influence of Information Collection Strategy on Designer’s Mental Stress
Zhao, M., & Zeng, Y. (2019) · Proceedings of the ... International Conference on Engineering Design · doi:10.1017/dsi.2019.184 · Cited by 4
“believed to be affected by mental stress (Hjortskov et al., 2004; Kumar et al., 2007; Salahuddin et al., 2007).”
BackgroundaVRaid of Heights? - Exploring Integrated Non-Invasive Sensors For Stress Testing
Weis, S., Withöft, A., & Heuten, W. (2020) · IEEE International Conference on Healthcare Informatics (ICHI) · doi:10.1109/ichi48887.2020.9374361 · Cited by 5
“This is also true for mental stress [25].”
BackgroundRETRACTED ARTICLE: Continuous Activity-Aware Stress Detection Using Sensors
Karthick, T., Sangeetha, M., Ramprasath, M., & Ananthajothi, K. (2021) · Wireless Personal Communications · doi:10.1007/s11277-021-08791-8 · Cited by 4
RetractedMeasuring Pedestrian Stress Response (MPSR) Using Wearable Technologies
Dash, I., Muscatello, R. A., Abkowitz, M., Mostoller, E. R., & Sewell, M. J. (2024) · Journal of Transportation Technologies · doi:10.4236/jtts.2024.142014 · Cited by 4
Selecting Physiological Features for Predicting Bidding Behavior in Electronic Auctions
Muller, M., Adam, M. T. P., Cornforth, D. J., Chiong, R., Krämer, J., & Weinhardt, C. (2016) · Hawaii International Conference on System Sciences (HICSS) · doi:10.1109/hicss.2016.55 · Cited by 4
“Especially in a non-clinical environment, such as an auction, where participants are not continuously observed for days or weeks but hours or even less, it is very challenging to derive meaning from existing standard measures [12, 13].”
BackgroundUnobtrusive real-time heart rate variability analysis for the detection of orthostatic dysregulation
Richer, R., Groh, B. H., Blank, P., Dorschky, E., Martindale, C. F., Klucken, J., & Eskofier, B. M. (2016) · Wearable and Implantable Body Sensor Networks · doi:10.1109/bsn.2016.7516257 · Cited by 4
“Solutions performing HRV analysis using wearable sensors were implemented for stress assessment [9], [10] or biofeedback [11].”
MethodPhysiological signals responses to normal and abnormal brake events in simulated autonomous car
Hu, Y., Nakamura, S., Yamanaka, T., & Tanaka, T. (2019) · Asia-Pacific Signal and Information Processing Association Annual Summit and Conference (APSIPA ASC) · doi:10.1109/apsipaasc47483.2019.9023194 · Cited by 6
“Heart rate variability (HRV) analysis is commonly used as a quantitative marker depicting the activity of autonomous nervous system (ANS) that may be related to mental stress and ultra short term analysis of heart rate and RR interval could be reliably performed for monitoring mental stress [10].”
MethodMobile Real-Time Stress Detection
Alexandratos, V. (2014) · Research Repository (Delft University of Technology) · Cited by 5
Understanding rumination as a form of inner speech: probing the role of motor processesPreprint
Nalborczyk, L. (2019) · Thesis Commons (OSF Preprints) · doi:10.31237/osf.io/p6dct · Cited by 7
Lustig, A., Benady, A., Gilaie‐Dotan, S., & Plotnik, M. (2025) · Psychophysiology · doi:10.1111/psyp.70072 · Cited by 3
“…influences (Laborde et al. 2017; McCraty and Shaffer 2015; Kleiger et al. 2005; Dionne et al. 2002; Larsen et al. 2010); and (iii) RMSSD provides meaningful information also in short and ultra-short time intervals (i.e., 10–50 s) (Laborde et al. 2017; Salahuddin et al. 2007; Munoz et al. 2015).”
Fan, W., Li, C., Gao, S., Ai, N., & Li, N. (2025) · Sustainability · doi:10.3390/su172310575 · Cited by 4
The Impact of Control Interface on Features of Heart Rate Variability
Javaremi, M. N., Wu, D., & Argall, B. (2021) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc46164.2021.9631053 · Cited by 3
Neural Diversity and Decisions
Thoelen, G., & Zak, P. J. (2024) · Adaptive Human Behavior and Physiology · doi:10.1007/s40750-024-00237-2 · Cited by 3
“This measure of vagal tone is typically used for short measurements (< 60 s; Salahuddin et al., 2007).”
Is it the darkness that you fear? The impact of anxiety on pedestrian tolerance for darkness
Jedon, R., Haans, A., van den Akkerveken, I., & de Kort, Y. A. W. (2025) · Journal of Environmental Psychology · doi:10.1016/j.jenvp.2025.102720 · Cited by 3
Stief, L., Sattel, H. C., Paschinger, K., Sack, M., & Schäflein, E. (2025) · BJPsych Open · doi:10.1192/bjo.2025.10072 · Cited by 3
“58 Other limitations might have arisen from the randomisation conducted by the first author (L.S.) and her presence throughout the experiment, as well as the use of individually tailored components, such as the selected audiobook, to minimise additional stress for the patients.”
Validation of a low intrusiveness heart rate sensor for stress assessment
Pereira, T., Almeida, P. R., Cunha, J. P. S., & Aguiar, A. (2017) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/3/1/017004 · Cited by 3
McIntosh, R. C., Khambaty, T., Llabre, M. M., Perreira, K. M., González, H. M., Kansal, M. M., Tarraf, W., & Schneiderman, N. (2021) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2021.01.019 · Cited by 4
“Moreover, ultra-short HRV measures are increasingly used to monitor mental stress in mobile settings (Castaldo et al., 2015; Salahuddin et al., 2007).”
BackgroundAutonomic Nervous System Assessment During Physical Rehabilitation Serious Game
Rodrigues, M. J., Postolache, O. A., & Cercas, F. (2021) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea52024.2021.9478742 · Cited by 3
KALP HIZI DEĞİŞKENLİĞİ VE EGZERSİZE KRONİK YANITLARI
Aras, D., Erdoğmuş, T. N., Ayvaz, Ö., & BİROL, A. (2022) · Ankara Üniversitesi Beden Eğitimi ve Spor Yüksekokulu SPORMETRE Beden Eğitimi ve Spor Bilimleri Dergisi · doi:10.33689/spormetre.1129126 · Cited by 3
Electrocardiographic activity depends on the relative position between intimate persons
Mukai, K., Isomura, T., Onagawa, R., & Watanabe, K. (2024) · Scientific Reports · doi:10.1038/s41598-024-54439-5 · Cited by 3
Lin, L., Huang, P., Cheng, Y., Jiang, S., Zhang, J., Li, M., Zheng, J., Pan, X., & Wang, Y. (2024) · CNS Neuroscience & Therapeutics · doi:10.1111/cns.14712 · Cited by 3
Biggs, A. T., Jensen, A. E., & Kelly, K. R. (2024) · Frontiers in Sports and Active Living · doi:10.3389/fspor.2024.1444655 · Cited by 4
Hinss, M. F., Jahanpour, E., Brock, A., & Roy, R. N. (2024) · Journal of Neural Engineering · doi:10.1088/1741-2552/ad9bed · Cited by 4
“Robust estimation of heart rate variability (HRV) metrics [44] require around 10 s to be estimated reliably.”
McLean, L., Antônio, F. I., Rodrigues, M. P., & Pukall, C. F. (2024) · The Journal of Sexual Medicine · doi:10.1093/jsxmed/qdae171 · Cited by 5
Effect of Wearing Whole Body Compression Garments on Cardiovascular Function using ECG Signals
Nguyen, L. T. N., Eager, D., & Nguyen, H. T. (2016) · IASTED International Conference on Telehealth and Assistive Technology (TAT) · doi:10.2316/p.2016.846-007 · Cited by 3
“All parameters of HRV were considered throughout the collected duration (90 seconds) [24].”
BackgroundAutonomic factors do not underlie the elevated self-disgust levels in Parkinson’s disease
Aristotelidou, V., Tsatali, M. S., Overton, P. G., & Vivas, A. B. (2021) · PLoS ONE · doi:10.1371/journal.pone.0256144 · Cited by 3
Physiological Signal Analysis and Classification of Stress from Virtual Reality Video Game
Khan, N., Ishaque, S., Rueda, A., Nguyen, B., & Krishnan, S. (2023) · doi:10.32920/22734275 · Cited by 3
de Yzaguirre, I., Escoda, J., Mónaco, M., Grazioli, G. C., Santiago, J., & Cuixart, D. B. I. (2025) · Apunts Sports Medicine · doi:10.1016/j.apunsm.2024.100472 · Cited by 3
Visualizing Relaxation in Wearables: Multi-Domain Feature Fusion of HRV Using Fuzzy Recurrence Plots
Arya, P., Singh, M., & Singh, M. (2025) · Sensors · doi:10.3390/s25134210 · Cited by 2
“In previous studies, researchers have assessed the changes in HRV through time-domain, graphical, frequency-domain, and non-linear methods, each contributing unique insights into autonomic nervous system (ANS) dynamics [17].”
Chi, H.-M., & Hsiao, T. (2025) · BioMedical Engineering OnLine · doi:10.1186/s12938-025-01471-9 · Cited by 2
Dynamic Difficulty Adjustment in Games: Concepts, Techniques, and Applications
Fisher, N., & Kulshreshth, A. K. (2025) · IntechOpen eBooks · doi:10.5772/intechopen.1011703 · Cited by 2
Digital biomarkers and ambulatory seizure detection in epilepsy clinical trials
Russo, E. E., Simmatis, L. E. R., Wu, T., Kadak, K., Harmsen, I. E., & Samuel, N. (2026) · Discover Neuroscience · doi:10.1186/s13064-026-00244-x · Cited by 2
Unveiling the Brain–Heart Connection: EEG and HRV Integration for Cognitive Stress Assessment
Salam, A., Alam, F., Rahman, S. U., Shah, D., Ali, S., Yousaf, M., & Tahir, M. (2026) · International Journal of Human-Computer Interaction · doi:10.1080/10447318.2026.2634977 · Cited by 2
Uendes, B., Antonides, A., van de Ven, S. R. B., van der Mee, D. J., de Geus, E. J. C., & Hoogendoorn, M. (2026) · Journal of Medical Internet Research · doi:10.2196/80450 · Cited by 3
“These include NN20 and NN50, the counts of consecutive interval differences exceeding 20 milliseconds and 50 milliseconds, and their normalized counterparts, PNN20 and PNN50, as these features are helpful for stress monitoring [33,34].”
Chandra, S., Pasupuleti, D., Castaneda, G. C., Zheng, C., Avijeet, P., Dixon, M. J., & Dautenhahn, K. (2026) · CHI Conference on Human Factors in Computing Systems · doi:10.1145/3772318.3790706 · Cited by 2
Bleier, C., Guthrie, A. J., Ranford, J., MacLean, J., Godena, E. J., Maggio, J., Finkelstein, S. A., Diez, I. P., Westlin, C., Quigley, K. S., et al. (2026) · NeuroImage Clinical · doi:10.1016/j.nicl.2026.103996 · Cited by 2
“…need for sufficiently reliable estimates per window, where 30 – 50 s has been reported to be sufficient to provide reliable estimates of HRV at rest (Salahuddin et al., 2007), while also retaining as many uninterrupted time series windows as possible to maximize the amount of data that could be…”
Maciejewska, K., Zając, C., Duch, K., Giza, M., & Masternak, A. (2026) · Scientific Reports · doi:10.1038/s41598-026-55797-y · Cited by 2
“A few other studies presented different results that suggested an acceptable agreement in 1-min recordings for SDNN or as short as 10 s for RMSSD 3,13,40 .”
Debnath, S., Levy, T. J., Zanos, S. P., & Zanos, T. P. (2021) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner49283.2021.9441419 · Cited by 2
“Ultrashort term (<5 minute) HRV measures are not common, but the root mean square of successive R-R interval differences (RMSSD) has been reported as a reliable index for parasympathetic activity down to 30 second intervals [13,14].”
BackgroundCholewinski, M., Machek, S. B., Cardaci, T. D., Wilburn, D. T., Willoughby, D. S., Funderburk, L., & Gallucci, A. R. (2022) · International Journal of Strength and Conditioning · doi:10.47206/ijsc.v2i1.115 · Cited by 2
“To avoid circadian fluctuations due to time of day and measurement position, subjects were instructed to complete measurements every morning after waking and emptying their bladder; they did so in a seated position and the total assessment time was about one-minute in length [32], [33].”
MethodPrice, A. I., Lin, Y. L., Levin, A. S., Tumietto, F., de Almeida, R. M. A., de Almeida, A. P. S. S., Ciofi-Silva, C. L., Fontana, L., de Oliveira, N. A., Parisi, N. F., et al. (2022) · JMIR Research Protocols · doi:10.2196/36549 · Cited by 2
Towards semi-automated pleural cavity access for pneumothorax in austere environments
L’Orsa, R., Lama, S., Westwick, D. T., Sutherland, G. R., & Kuchenbecker, K. J. (2023) · Acta Astronautica · doi:10.1016/j.actaastro.2023.07.029 · Cited by 2
Chandra, S., Sharma, I., Schnapp, B. D., Dixon, M. J., & Dautenhahn, K. (2023) · IEEE RO-MAN · doi:10.1109/ro-man57019.2023.10309350 · Cited by 2
“This duration was required for the accurate calculation of di ff erent HRV features [32] and was determined based on discussions with experts and our previous experimentations.”
MethodComparing stress markers across various cohorts in a mobile setting
Gandhi, S., Jain, J., Baghini, M. S., & Mukherji, S. (2013) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6611237 · Cited by 2
Physiological Responses of the Youth Viewing a Japanese Garden
Zhang, Y., Liu, C., Herrup, K., & Shi, B. E. (2018) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2018.8512462 · Cited by 3
“relative to the parasympathetic branch is associated with increased mental stress [5].”
Background
Metadata
- Authors
- Salahuddin, L., Cho, J., Jeong, M. G., & Kim, D.
- Affiliations
- Samsung Electronics (South Korea) (KR)
- Venue
- 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Publisher
- IEEE
- Published
- 2007-08
- Volume
- 2007
- Pages
- 4656-4659
- ISSN
- 1557-170X (ISSN-L)
- OpenAlex
- W2162033213
- Cited by
- 374
- References
- 27
- Citations by year
- 2026: 19 · 2025: 32 · 2024: 34 · 2023: 35 · 2022: 42 · 2021: 35 · 2020: 24 · 2019: 40 · 2018: 26 · 2017: 17 · 2016: 13 · 2015: 10 · 2014: 9 · 2013: 13 · 2012: 6
- FWCI
- 10.21
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- Conference proceedings (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Samsung
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Physical Sciences › Computer Science › Artificial Intelligence › Emotion and Mood Recognition
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Keywords
- heart rate variability, psychological stress, mobile health monitoring, Stroop task, RR interval, RMSSD, pNN50, autonomic nervous system, stress measurement
- MeSH terms
- Autonomic Nervous System, Electrocardiography, Heart Rate, Humans, Monitoring, Physiologic, Stress, Psychological, Time Factors, Biosensing Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.