Ultra short term analysis of heart rate variability for monitoring mental stress in mobile settings.
The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
Heart rate variability (HRV) analysis is commonly used as a quantitative marker depicting the activity of autonomous nervous system (ANS) that may be related to mental stress. For mobile applications, short term ECG measurement may be used for HRV analysis since the conventional five minute long recordings might be inadequately long. Short term analysis of HRV features has been investigated mostly in ECG data from normal and cardiac patients. Thus, short term HRV features may not have any relevance on the assessment of acute mental stress. In this study, we obtained ultra short term HRV features from 24 subjects during baseline stage and Stroop color word test. We validated these HRV features by showing significant differences in HRV features existed between the two stages. Our results indicated that ultra short term analysis of heart rate and RR intervals within 10 s, RMSSD and PNN50 within 30 s, HF within 40 s, LF/HF, normalized LF, and normalized HF within 50 s could be reliably performed for monitoring mental stress in mobile settings.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Furthermore recordings between 10 and 50 s, according to which HRV parameters are considered, have been proven to be reliable under certain conditions (Salahuddin et al., 2007).”
From Heart Rate Variability and Cardiac Vagal Tone in Psychophysiological Research – Recommendations for Experiment Planning, Data Analysis, and Data Reporting (2017) · cites this paper as Salahuddin et al., 2007
Citations
Cites
The PHQ-9: Validity of a brief depression severity measure
Kroenke, K., Spitzer, R. L., & Williams, J. B. W. (2001) · Journal of General Internal Medicine · doi:10.1046/j.1525-1497.2001.016009606.x · Cited by 44,910
Heart rate variability: Standards of measurement, physiological interpretation, and clinical use
Malik, M., Bigger, J. T., Camm, A. J., Kleiger, R. E., Malliani, A., Moss, A. J., & Schwartz, P. J. (1996) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a014868 · Cited by 15,289 · cited 2×
“EART Rate Variability (HRV) has been traditionally calculated from five minute or 24 hour ECG recordings for the analysis of cardiac diseases [1].”
Welch, P. (1967) · IEEE Transactions on Audio and Electroacoustics · doi:10.1109/tau.1967.1161901 · Cited by 12,277 · cited 1×
“Frequency domain features were calculated by Welch’s averaging method [23].”
MethodAnterior Cingulate Cortex, Error Detection, and the Online Monitoring of Performance
Carter, C. S., Braver, T. S., Barch, D. M., Botvinick, M. M., Noll, D., & Cohen, J. D. (1998) · Science · doi:10.1126/science.280.5364.747 · Cited by 3,273 · cited 2×
“In addition, it was also widely used in various neurological studies [11-15, 25].”
BackgroundMethodPardo, J. V., Pardo, P. J., Janer, K. W., & Raichle, M. E. (1990) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.87.1.256 · Cited by 1,495 · cited 2×
“In addition, it was also widely used in various neurological studies [11-15, 25].”
BackgroundMethodHuman cingulate cortex and autonomic control: converging neuroimaging and clinical evidence
Critchley, H. D., Mathias, C. J., Josephs, O., O’Doherty, J., Zanini, S., Dewar, B., Cipolotti, L., Shallice, T., & Dolan, R. J. (2003) · Brain · doi:10.1093/brain/awg216 · Cited by 1,201 · cited 2×
“In addition, it was also widely used in various neurological studies [11-15, 25].”
BackgroundMethodThe effect of mental stress on heart rate variability and blood pressure during computer work
Hjortskov, N., Riss�n, D., Blangsted, A. K., Fallentin, N., Lundberg, U., & S�gaard, K. (2004) · European Journal of Applied Physiology · doi:10.1007/s00421-004-1055-z · Cited by 766 · cited 1×
“Mental stress increased sympathetic activity (low frequency HRV) and blood pressure [8] but decreased parasympathetic activity (high frequency HRV) [9, 10].”
BackgroundStressed or Stressed out: What Is the Difference?
McEwen, B. S. (2005) · Journal of Psychiatry and Neuroscience · doi:10.1139/jpn.0540 · Cited by 593 · cited 1×
“The concept of allostasis has been introduced to explain how adaptive processes maintain stability or homeostasis through the production of mediators such as stress hormone, neurotransmitter, and cytokines [7].”
BackgroundForebrain Pathways Mediating Stress-Induced Hormone Secretion
Van de Kar, L. D., & Blair, M. L. (1999) · Frontiers in Neuroendocrinology · doi:10.1006/frne.1998.0172 · Cited by 380 · cited 1×
“In response to stress, the brain activates the secretion of numerous hormones, including corticosterone/cortisol, catecholamine, prolactin, oxytocin, and renin, as a part of the survival mechanism [6].”
BackgroundThe reliability of short-term measurements of heart rate variability
Sandercock, G. R. H., Bromley, P. D., & Brodie, D. A. (2005) · International Journal of Cardiology · doi:10.1016/j.ijcard.2004.09.013 · Cited by 307 · cited 1×
“HRV features sensitive to low frequency components of HRV had poor repeatability and cannot be estimated accurately from ECG segments shorter than 10 min [4].”
Method
Research works printed but not linked: 2
- bayevsky, 2002, HRV Analysis under the usage of different electrocardiography systems (Methodical recommendations)
- s?is?ka, 2002, The Stroop Colour-Word Test in Psychology and Biomedicine, Acta Univ Palacki Olomuc Gymn, 32, 45
Cited by
Items 101–200 of 415
Meteier, Q., de Salis, E., Capallera, M., Widmer, M., Angelini, L., Khaled, O. A., Sonderegger, A., & Mugellini, E. (2022) · Frontiers in Computer Science · doi:10.3389/fcomp.2021.775282 · Cited by 27
“Recent studies have shown that 10–60 s may be sufficient to obtain reliable time-based measurements of HRV, whereas 20–90 s may be sufficient to capture changes in the autonomic nervous system using frequency-based measures (Salahuddin et al., 2007; Baek et al., 2015).”
BackgroundMitsis, K., Zarkogianni, K., Kalafatis, E., Dalakleidi, K. V., Jaafar, A., Mourkousis, G., & Nikita, K. S. (2022) · Sensors · doi:10.3390/s22072472 · Cited by 27
“Reactive frames of different duration, 10 s and 30 s, were investigated in accordance with current practice for ultra-short analysis of heart rate variability [45,46].”
MethodA Novel Rapid Assessment of Mental Stress by Using PPG Signals Based on Deep Learning
Wang, Z., & Wu, Y.-C. (2022) · IEEE Sensors Journal · doi:10.1109/jsen.2022.3208427 · Cited by 24
Mehrang, S., Pietilä, J., Tolonen, J., Helander, E. E., Jimison, H. B., Pavel, M., & Korhonen, I. (2017) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-981-10-5122-7_147 · Cited by 27
Arousal detection by using ultra-short-term heart rate variability (HRV) analysis
Faskhodi, M. M., Fernández-Chimeno, M., & García-González, M. A. (2023) · Frontiers in Medical Engineering · doi:10.3389/fmede.2023.1209252 · Cited by 29
Camera-Based Seismocardiogram for Heart Rate Variability Monitoring
Liu, L., Yu, D., Lu, H., Shan, C., & Wang, W. (2024) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2024.3370394 · Cited by 23
“It is widely acknowledged as a reliable method to evaluate ANS dysfunction [1], [2], [3], [4].”
BackgroundMethodUncertainty in heart rate complexity metrics caused by R-peak perturbations
Napoli, N. J., Demas, M., Mendu, S., Stephens, C. L., Kennedy, K. D., Harrivel, A. R., Bailey, R. E., & Barnes, L. E. (2018) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2018.10.009 · Cited by 23
“One major physiological component that is leveraged in order to gain these insights is the sympathetic nervous system, which is the part of the autonomic nervous system responsible for monitoring and adapting to stress imposed on the body [7],”
BackgroundPrediction of Daily Mental Stress Levels Using a Wearable Photoplethysmography Sensor
Park, J., Kim, J., & Kim, S.-P. (2018) · IEEE Region 10 Conference (TENCON) · doi:10.1109/tencon.2018.8650109 · Cited by 26
“[18], ultra-short-term HRV less than one minute can provide a meaningful indicator of mental stress.”
BackgroundEffects of ECG Data Length on Heart Rate Variability among Young Healthy Adults
Chou, E., Khine, M., Lockhart, T. E., & Soangra, R. (2021) · Sensors · doi:10.3390/s21186286 · Cited by 24
“In addition, the study showed that 40-s HF and 50-s LF/HF, LF norm and HF norm were reliable to monitor mental stress under a mobile setting [31].”
BackgroundResultNaim, R., Goodwin, M. S., Dombek, K., Revzina, O., Agorsor, C. F., Lee, K., Botz-Zapp, C. A., Freitag, G. F., Haller, S. P., Cardinale, E. M., et al. (2021) · International Journal of Methods in Psychiatric Research · doi:10.1002/mpr.1890 · Cited by 22
Heart-rate variability as a new marker for freezing predisposition in Parkinson's disease
Heimler, B., Koren, O., Inzelberg, R., Rosenblum, U., Hassin‐Baer, S., Zeilig, G., Bartsch, R. P., & Plotnik, M. (2023) · Parkinsonism & Related Disorders · doi:10.1016/j.parkreldis.2023.105476 · Cited by 22
Improving heart rate variability measurements from consumer smartwatches with machine learning
Maritsch, M., Bérubé, C., Kraus, M., Lehmann, V., Züger, T., Feuerriegel, S., Kowatsch, T., & Wortmann, F. (2019) · ACM International Joint Conference on Pervasive and Ubiquitous Computing (UbiComp) · doi:10.1145/3341162.3346276 · Cited by 25
“ces (RMSSD) in the time domain. However, RMSSD has been found to be reliable when calculated with a sample of 10, 30 or 60 seconds, which was not always the case for SDNN, or frequency-based measures [1, 7, 16, 17, 21, 23]. Ultra-short-term measures of HRV such as RMSSD would thus allow monitoring streams of physiolog…”
MethodAcute Mental Stress Detection via Ultra-short term HRV Analysis
Castaldo, R., Melillo, P., & Pecchia, L. (2015) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-319-19387-8_260 · Cited by 21
Villarejo, M., Zapirain, B., & Zorrilla, A. (2013) · Sensors · doi:10.3390/s130506141 · Cited by 20
“This test has been used in different studies to induce stress in people [11,12].”
MethodAssessing Stress Level Scores Against Wearables‐Driven Physiological Measurements
Rosenbach, H., Itzkovitch, A., Gidron, Y., & Schönberg, T. (2025) · Stress and Health · doi:10.1002/smi.70125 · Cited by 23
Co‐ordination of brain and heart oscillations during non‐rapid eye movement sleep
Mikutta, C. A., Wenke, M., Spiegelhalder, K., Hertenstein, E., Maier, J. G., Schneider, C. L., Fehér, K. D., Koenig, J., Altorfer, A., Riemann, D. W., et al. (2021) · Journal of Sleep Research · doi:10.1111/jsr.13466 · Cited by 21
“Several studies confirmed the reliability of ultra-short HRV frequency analysis (Lischke et al., 2018; Salahuddin, Cho, Jeong, & Kim, 2007 ; Seps, Beckers, & Aubert, 2002).”
Adarsh, V., & Gangadharan, G. R. (2024) · Machine Learning · doi:10.1007/s10994-023-06504-9 · Cited by 22
“Thus, HRV provides a longer-term view of an individual’s physiological state, while US-HRV gives a more immediate and dynamic view.”
InfluentialRemoval of Subject-Dependent and Activity-Dependent Variation in Physiological Measures of Stress
Alamudun, F., Choi, J., Khan, H. M., Ahmed, B., & Gutiérrez‐Osuna, R. (2012) · International Conference on Pervasive Computing Technologies for Healthcare · doi:10.4108/icst.pervasivehealth.2012.248722 · Cited by 20
“The concept of orthogonal signal correction (OSC) was originally introduced by Wold et al. [8] as a preprocessing step for removal of systematic noise such as baseline variation and multiplicative scatter effects in near-infrared (NIR) spectra.”
MethodTsuji, T., Nobukawa, T., Mito, A., Hirano, H., Soh, Z., Inokuchi, R., Fujita, E., Ogura, Y., KANEKO, S., Nakamura, R., et al. (2020) · Scientific Reports · doi:10.1038/s41598-020-68627-6 · Cited by 22
Leveraging biosignal and collaborative filtering for context-aware recommendation
Alhamid, M. F., Rawashdeh, M., Osman, H. A., & Saddik, A. E. (2013) · doi:10.1145/2505323.2505332 · Cited by 20
“However, we used the short term analysis of the heart rate variability proposed by [19] to tell if there is a potential of the user being in elevated stress state, neutral state, or relaxed state as in Figure 1.”
BackgroundMethodShort Term Analysis of Long Term Patterns of Heart Rate Variability in Subjects under Mental Stress
Kim, D., Seo, Y., Kim, S.-H., & Jung, S. (2008) · International Conference on Biomedical Engineering and Informatics (BMEI) · doi:10.1109/bmei.2008.272 · Cited by 23
“Fourteen HRV metrics were calculated from the heartbeat interval data of PPG sensors using our previously developed software [16, 17, 20, 21]: mean heart rate (Mean HR), mean heartbeat intervals (Mean RR) , standard deviation of the RRintervals between normal beats (SDNN), the coefficient of variation (CV), root mean…”
MethodSelf-citationEffects of Acoustic Environment Types on Stress Relief in Urban Parks
Zhang, J., Yan, H.-L., & Wang, D. (2023) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph20021082 · Cited by 23
“There are long-range (12–24 h) and short-range tests (t ≤ 5 min) for obtaining HRV by ECG testing, and SDANN and RMSSD are commonly used in short-term HRV analysis [31].”
BackgroundChang, X., Chen, Z., Dong, X., Cai, Y., Yan, T., Cai, H., Zhou, Z., Zhou, G., & Gong, J. (2024) · CHI Conference on Human Factors in Computing Systems · doi:10.1145/3613904.3642029 · Cited by 19
“[50, 56]”
Nguyen, N. T. P., Lyu, P.-Y., Lin, M. H., Chang, C., & Chang, S. (2019) · IEEE MTT-S International Microwave Biomedical Conference (IMBioC) · doi:10.1109/imbioc.2019.8777797 · Cited by 19
“While the conventional minimum ECG recording is five minutes, Salahuddin et al [14] have validated that a shortterm period of 10-40 s is as reliable as the conventional fiveminute measurement.”
MethodQiu, X., Tian, F., Shi, Q., Zhao, Q., & Hu, B. (2020) · IEEE International Conference on Bioinformatics and Biomedicine (BIBM) · doi:10.1109/bibm49941.2020.9313129 · Cited by 21
Shah, A. S., Alonso, Á., Whitsel, E. A., Soliman, E. Z., Vaccarino, V., & Shah, A. J. (2021) · Journal of the American Heart Association · doi:10.1161/jaha.120.017172 · Cited by 19
Thierfelder, A., Primbs, J., Severitt, B., Hohnecker, C. S., Kühnhausen, J., Alt, A. K., Pascher, A., Wörz, U., Passon, H., Seemann, J., et al. (2022) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc48229.2022.9871899 · Cited by 19
“to identify stressful periods in short windows [19].”
BackgroundAssist the VR Trainer – Real-Time Dashboard and After-Action Review for Police VR Training
Murtinger, M., Uhl, J. C., Schrom-Feiertag, H., Nguyen, Q., Harthum, B., & Tscheligi, M. (2022) · IEEE International Conference on Metrology for eXtended Reality, Artificial Intelligence and Neural Engineering (MetroXRAINE) · doi:10.1109/metroxraine54828.2022.9967532 · Cited by 20
Ultra-short-term heart rate variability during resistance exercise in the elderly
Arêas, G. P. T., Caruso, F., Simões, R. P., Castello‐Simões, V., Jaenisch, R. B., Sato, T. D. O., Cabiddu, R., Mendes, R. G., Arena, R. A., & Borghi‐Silva, A. (2018) · Brazilian Journal of Medical and Biological Research · doi:10.1590/1414-431x20186962 · Cited by 22
Randomized neural networks for preference learning with physiological data
Bacciu, D., Colombo, M., Morelli, D., & Plans, D. (2018) · Neurocomputing · doi:10.1016/j.neucom.2017.11.070 · Cited by 18
Sinabro: opportunistic and unobtrusive mobile electrocardiogram monitoring system
Kang, S., Kwon, S., Yoo, C., Seo, S., Park, K., Song, J., & Lee, Y. (2014) · IEEE Workshop on Mobile Computing Systems and Applications (WMCSA) · doi:10.1145/2565585.2565605 · Cited by 21
“Finally, HR and HRV are calculated from the peaks obtained [9], and other data, such as stress and affective state, are further derived based on HR and HRV [8][10].”
InfluentialAras, S. G., Runyon, J. R., Kazman, J. B., Thayer, J. F., Sternberg, E. M., & Deuster, P. A. (2024) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph21111491 · Cited by 17
Physiological reaction of passengers stress metro fire using virtual reality technology
Lin, X., Shou-xin, S., Zhai, H., Yuan, P., & Chen, M. (2020) · International Journal of Systems Assurance Engineering and Management · doi:10.1007/s13198-020-00991-y · Cited by 17
“Heart rate (HR for short) and blood pressure (BP for short) are recognized at home and abroad a reliable indicator of human stress level (Mulder et al. 2004), which are closely related to the activities of the human autonomic nervous system (Salahuddin et al. 2007).”
BackgroundKim, D., Seo, Y., & Salahuddin, L. B. (2008) · International Conference on Pervasive Computing Technologies for Healthcare · doi:10.1109/pcthealth.2008.4571093 · Cited by 20
Self-citationWang, W., Wei, Z., Yuan, J., Fang, Y. C., & Zheng, Y. (2022) · PLoS ONE · doi:10.1371/journal.pone.0275544 · Cited by 16
You, S., Cho, B. H., Bae, H., Kim, Y., Kim, J.-R., Park, S., Shon, Y., Seo, D., & Kim, I. Y. (2023) · Journal of Clinical Medicine · doi:10.3390/jcm12134284 · Cited by 17
“correlated with seizure frequency (r[49] = 0.”
BackgroundMethodInfluentialZhang, H., Wang, Z., Zhuang, Y., Yin, S., Chen, Z., & Liang, Y. (2024) · Electronics · doi:10.3390/electronics13071238 · Cited by 16
Timberlake, M. D., Stefanidis, D., & Gardner, A. K. (2018) · Surgical Endoscopy · doi:10.1007/s00464-018-6163-7 · Cited by 16
Vasudha, M. S., Manjunath, N. K., & Nagendra, H. R. (2018) · Annals of Neurosciences · doi:10.1159/000492269 · Cited by 20
Ultra-short term heart rate variability as a tool to assess changes in valence
Schippers, A., Aben, B., Griep, Y., & Overwalle, F. V. (2018) · Psychiatry Research · doi:10.1016/j.psychres.2018.10.005 · Cited by 20
Carrillo, A. E., Flouris, A. D., Herry, C. L., Notley, S. R., Macartney, M. J., SEELY, A. J. E., Wright, H. E., & Kenny, G. P. (2019) · Temperature · doi:10.1080/23328940.2019.1684791 · Cited by 16
“It is believed that CoV is a marker of short-term vagal cardiac autonomic modulation [9].”
BackgroundHashiguchi, N., Cao, J., Lim, Y., Kuroishi, S., Miyazaki, Y., Kitahara, S., Sengoku, S., Matsubayashi, K., & Kodama, K. (2021) · JMIR mhealth and uhealth · doi:10.2196/31637 · Cited by 18
“The use of wearable devices to monitor autonomic nervous system activity through heart rate (HR) observations is economical, with easy access to data [10,11].”
BackgroundMeasuring brain beats: Cardiac‐aligned fast functional magnetic resonance imaging signals
Hermes, D., Wu, H., Kerr, A. B., & Wandell, B. A. (2022) · Human Brain Mapping · doi:10.1002/hbm.26128 · Cited by 16
“Since the scans only had a duration of 220 s, we quantified heart rate variability across ultrashort intervals (20 s) as in Salahuddin et al. (2007), using the root mean square of successive differences (Supplemental F IGURE 1 Temporal alignment of magnetic resonance imaging (MRI) measurements to…”
MethodAssociation of mental stress with video games
Subahni, A. R., Xia, L., & Malik, A. S. (2012) · International Conference on Intelligent and Advanced Systems · doi:10.1109/icias.2012.6306164 · Cited by 16
“One more study [5], analyzed HRV as a quantitative marker to depict ANS activity to represent mental stress.”
BackgroundGu, Z., Zarubin, V. C., & Martsberger, C. (2023) · Physiological Reports · doi:10.14814/phy2.15863 · Cited by 16
“Baek et al. found that 60s ECG is sufficient to derive pNN50 (Baek et al., 2015).”
BackgroundResultInfluentialGotthardt, K. A., Rakoczy, K., Tallon, M., Seitz, M., & Frick, U. (2023) · Empirical Studies of the Arts · doi:10.1177/02762374231221920 · Cited by 17
“Regarding HR, 10s measurements also seem to correlate with longer measurements (Salahuddin et al., 2007; Shaffer, Shearman, & Meehan, 2016).”
Identifying neurophysiological correlates of stress
Pei, D., Tirumala, S., Tun, K. T., Ajendla, A., & Vinjamuri, R. K. (2024) · Frontiers in Medical Engineering · doi:10.3389/fmede.2024.1434753 · Cited by 18
Fló, E., Belloli, L. M. L., Cabana, Á., Ruyant-Belabbas, A., Jodaïtis, L., Denis-Valente, M., Rohaut, B., Naccache, L., Rosanova, M., Comanducci, A., et al. (2024) · PNAS Nexus · doi:10.1093/pnasnexus/pgae531 · Cited by 16
Gradl, S., Cibis, T., Lauber, J., Richer, R., Rybalko, R., Pfeiffer, N., Leutheuser, H., Wirth, M., von Tscharner, V., & Eskofier, B. M. (2017) · Applied Sciences · doi:10.3390/app7121277 · Cited by 18
“Therefore, HRV is a highly relevant measure for assessing the autonomous nervous system and has been used for analyzing stress [5], sudden cardiac death [6], or Parkinson’s Disease [7].”
BackgroundPrada, E. J. A., & Higinio, A. P. (2020) · Physiological Measurement · doi:10.1088/1361-6579/ab7878 · Cited by 15
Whiting, W. L., & Murdock, K. K. (2021) · Quarterly Journal of Experimental Psychology · doi:10.1177/17470218211041851 · Cited by 25
“Specifically, we found measurable effects of notifications on HRV, even though the measurement period was limited to 6 s, affirming the viability of assessing HRV in brief (around 10 s) time intervals (Chen et al., 2014; McNames & Aboy, 2006; Munoz et al., 2015; Salahuddin et al., 2007).”
BackgroundMartin, J., Schneider, F., Kowalewskij, A., Jordan, D., Hapfelmeier, A., Kochs, E. F., Wagner, K. J., & Schulz, C. M. (2016) · British Journal of Anaesthesia · doi:10.1093/bja/aew342 · Cited by 15
Brabant, O., van de Ree, M., & Erkkilä, J. (2017) · The Arts in Psychotherapy · doi:10.1016/j.aip.2017.08.004 · Cited by 18
Abdominothoracic Postural Tone Influences the Sensations Induced by Meal Ingestion
Livovsky, D. M., Barber, C., Barba, E., Accarino, A. M., & Azpiroz, F. (2021) · Nutrients · doi:10.3390/nu13020658 · Cited by 15
Altered interpersonal distance regulation in autism spectrum disorder
Farkas, K., Pesthy, O., Guttengéber, A., Weigl, A. S., Veres, A., Székely, A., Komoróczy, E., Szuromi, B., Janacsek, K., Réthelyi, J., et al. (2023) · PLoS ONE · doi:10.1371/journal.pone.0283761 · Cited by 16
“HRV was estimated as the root mean square of successive RR interval differences (Root Mean Square of Successive Differences, RMSSD) since this measurement is relatively resistant to by-products caused by breathing [60], and can be obtained for a shorter (10 seconds) period of time [61].”
BackgroundMethodKageyama, I., Hashiguchi, N., Cao, J., Niwa, M., Lim, Y., Tsutsumi, M., Yu, J., Sengoku, S., Okamoto, S., Hashimoto, S., et al. (2022) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph192315964 · Cited by 15
“The use of wearable devices to observe working conditions through the measurement of heart rate (HR), body temperature, and physical activity (PA) is rapidly gaining popularity [8,9].”
BackgroundCardiorespiratory Fitness Predicts Greater Vagal Autonomic Activity in Drug Users Under Stress
Cabral, D. A. R., da Costa, K. G., Tavares, V. D. D. O., Rêgo, M. L. D. M., Faro, H., & Fontes, E. B. (2019) · Substance Abuse Research and Treatment · doi:10.1177/1178221819862283 · Cited by 15
Goats discriminate emotional valence in the human voice
Mason, M. A., Semple, S., Marshall, H. H., & McElligott, A. G. (2024) · Animal Behaviour · doi:10.1016/j.anbehav.2023.12.008 · Cited by 13
“In humans, forexample, accurate HRV measurements (RMSSD) may be obtained within 30 s, although a period of around 5 min is more conventionally used (Salahuddin et al., 2007; Shaffer & Ginsberg, 2017), with 5 min also being recommended in horses, for which heart arrhythmias are common (Stucke et…”
MethodMental stress assessment - a comparison between HRV based and respiration based techniques
Gandhi, S., Baghini, M. S., & Mukherji, S. (2015) · Computing in cardiology · doi:10.1109/cic.2015.7411089 · Cited by 13
“Inhalation and exhalation during breathing is related to the sympathetic (SNS) and parasympathetic nervous system (PNS) balance.”
Patanè, A., & Kwiatkowska, M. (2019) · Lecture notes in computer science · doi:10.1007/978-3-030-13709-0_1 · Cited by 19
“Based on empirical results from ultra-short term HRV analysis [18], we use time windows of 15 seconds, as these provide just enough information to extract significant features from the ECG signal.”
MethodValente, A., Lee, D., Choi, S., Billinghurst, M., & Esteves, A. (2024) · ACM Symposium on User Interface Software and Technology (UIST) · doi:10.1145/3654777.3676435 · Cited by 15
“We employed the Ultra-short-term protocol by Salahuddin et al.[46] and a window of 60s for the analysis of time domain features of heart rate and heart rate variability, specifcally Root Mean Square of the Successive Diferences (RMSSD).”
Buchner, S. L., Kintz, J. R., Zhang, J. Y., Banerjee, N. T., Clark, T. K., & Anderson, A. P. (2025) · Journal of Cognitive Engineering and Decision Making · doi:10.1177/15553434241310084 · Cited by 14
“…are typically calculated over 5 minutes or 24 hours, some studies suggest that these metrics can be calculated over a 10 – 60 second duration (depending on the metric) and achieve comparable results (Esco & Flatt, 2014; Salahuddin et al., 2007; Shaffer et al., 2016; Shaffer & Ginsberg, 2017).”
Heart Rate Variability Analysis: Application Overview
Londhe, A. N., & Atulkar, M. (2018) · International Conference Inventive Communication and Computational Technologies · doi:10.1109/icicct.2018.8473198 · Cited by 13
“However, there are few methodological limitations are found in many of the UST based studies [35][36][48].”
BackgroundProbing ECG-based mental state monitoring on short time segments
Roy, R. N., Charbonnier, S., & Campagne, A. (2013) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6611071 · Cited by 12
Nagai, M., Ewbank, H., Nakano, Y., Scherlag, B. J., Po, S. S., & Dasari, T. W. (2024) · Current Cardiology Reviews · doi:10.2174/011573403x327105241021180916 · Cited by 11
“The conventional minimum recording for rMSSD is 5 minutes, while some researchers have proposed ultra-short recordings of 10 seconds [38].”
Improving Heart Rate Variability Measurements from Consumer Smartwatches with Machine Learning
Maritsch, M., Bérubé, C., Kraus, M., Lehmann, V. F., Züger, T., Feuerriegel, S., Kowatsch, T., & Wortmann, F. (2019) · Alexandria (UniSG) (University of St.Gallen) · doi:10.7892/boris.138443 · Cited by 11
Introducing MDPSD, a Multimodal Dataset for Psychological Stress Detection
Chen, W., Zheng, S., & Sun, X. N. (2021) · Communications in computer and information science · doi:10.1007/978-981-16-0705-9_5 · Cited by 13
Cipresso, P., Serino, S., Borghesi, F., Tartarisco, G., Riva, G., Pioggia, G., & Gaggioli, A. (2021) · ACTA IMEKO · doi:10.21014/acta_imeko.v10i4.1183 · Cited by 12
Sinabro: A Smartphone-Integrated Opportunistic Electrocardiogram Monitoring System
Kwon, S., Lee, D., Kim, J., Lee, Y., Kang, S., Seo, S., & Park, K.-S. (2016) · Sensors · doi:10.3390/s16030361 · Cited by 11
“The time durations were 10–30 s and 30–60 s for heart rate (HR) and ultra-short-term heart rate variability (HRV) analysis [5,11], 1–2 min for the high-frequency HRV components [1], 2–5 min for the low-frequency HRV components [1] and five or more minutes, which is the typically recommended duration for HRV analysis […”
BackgroundMethodInfluentialYou, S., Jo, H., Cho, B. H., Song, J., Kim, D., Hwang, Y., Shon, Y., Seo, D., & Kim, I. Y. (2021) · Medicina · doi:10.3390/medicina57070666 · Cited by 11
“[41] showed that 60 s is enough to estimate the HRV parameters in 24 healthy subjects.”
BackgroundSelf-citationRobust Adaptive Heart-Rate Monitoring Using Face Videos
Gupta, P., Bhowmik, B., & Pal, A. (2018) · IEEE Winter Conference on Applications of Computer Vision · doi:10.1109/wacv.2018.00064 · Cited by 11
“Applicability of HR monitoring in the human physiological and pathological parameters evaluation, has elicited the attention of the following fields: i) Healthcare, for understanding nervous system, analyzing cardiac diseases and monitoring exercise [22]; ii) psychology, for monitoring the stress and understand the me…”
BackgroundInfluentialSchneider, R. (2019) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2019.102478 · Cited by 11
Dasari, T. W., Nagai, M., Ewbank, H., Chakraborty, P., & Po, S. S. (2024) · Clinical Autonomic Research · doi:10.1007/s10286-024-01064-x · Cited by 11
“The conventional minimum recording for rMSSD is 5 min, while some researchers have proposed ultra-short recordings of 10 s [21].”
Schütz, L., Dehghani, S., Sommersperger, M., Faridpooya, K., & Navab, N. (2025) · Scientific Reports · doi:10.1038/s41598-025-07670-7 · Cited by 10
“Researchers have shown the validity of RMSSD for the analysis of mental stress for up to time periods as short as 10 seconds 55 .”
Prefrontally modulated vagal neuroimmunomodulation is associated with telomere length
Ask, T. F., & Sütterlin, S. (2022) · Frontiers in Neuroscience · doi:10.3389/fnins.2022.1063162 · Cited by 11
Taman, H. I., Mageed, N. A., Elmorsy, M. M., Elfayoumy, S. I., Elawady, M. S. A. M., Farid, A. M., Abdelmonem, M., & Abdelbaser, I. (2023) · BMC Anesthesiology · doi:10.1186/s12871-023-01975-8 · Cited by 10
“c) RMSSD, the root mean square of successive heart beat interval differences in 24 h ( 30 ± 12 ms) [12, 13].”
BackgroundHow to properly evaluate cardiac vagal tone in oncology studies: a state-of-the-art review
Martinez, P., Grinand, M., Cheggour, S., Taieb, J., & Gourjon, G. (2024) · Journal of the National Cancer Center · doi:10.1016/j.jncc.2024.02.002 · Cited by 14
Powezka, K., Adjei, T., von Rosenberg, W., Normahani, P., Goverdovsky, V., Standfield, N. J., Mandic, D. P., & Jaffer, U. (2019) · Journal of Vascular Surgery Venous and Lymphatic Disorders · doi:10.1016/j.jvsv.2018.08.008 · Cited by 10
Kennedy-Metz, L. R., DIAS, R. D., Srey, R., Rance, G. C., Conboy, H. M., Haime, M. E., Quin, J. A., Yule, S., & Zenati, M. A. (2020) · Human Factors The Journal of the Human Factors and Ergonomics Society · doi:10.1177/0018720820976297 · Cited by 10
“…recent evidence supports the accuracy and reliability of calculating HRV on ultra- short time scales, using time windows as narrow at 10 s (Baek et al., 2015; Munoz et al., 2015; Nussinovitch et al., 2011; Salahuddin et al., 2007; Schaaff & Adam, 2013; Shaffer et al., 2016; Thong et al., 2003).”
MethodHeart Rate Variability-A Bibliographical Survey
Singh, D., Saini, B. S., & Kumar, V. (2008) · IETE Journal of Research · doi:10.1080/03772063.2008.10876201 · Cited by 12
Depression Analysis using ECG Signal
Mantri, P. S., Agrawal, P., Patil, P. D., & Wadhai, V. M. (2013) · INTERNATIONAL JOURNAL OF COMPUTERS & TECHNOLOGY · doi:10.24297/ijct.v11i7.3470 · Cited by 10
“15 Hz), and normalized high frequency band within 50 sec can be reliably used for monitoring mental stress in mobile settings [7].”
MethodHillege, R. H. L., Lo, J. C., Janssen, C. P., & Romeijn, N. (2020) · Lecture notes in computer science · doi:10.1007/978-3-030-50788-6_24 · Cited by 12
“For heart rate features, time-domain features were reliably found from 20-second windows, and frequency domain features from 120-second windows [43,44].”
BackgroundMethodSoliński, M., Reed, C. N., & Chew, E. (2024) · Frontiers in Psychology · doi:10.3389/fpsyg.2024.1403599 · Cited by 9
AdaptAI: A Personalized Solution to Sense Your Stress, Fix Your Mess, and Boost Productivity
Gadhvi, R., Petkar, S., Desai, P. P., Ramachandran, S., & Siddharth, S. (2025) · CHI Conference Extended Abstracts on Human Factors in Computing Systems (CHI EA) · doi:10.1145/3706599.3720284 · Cited by 10
“…are defined to categorize stress levels: if the user’s pNN50 is below 20, the user is classified as being under high stress ; if the pNN50 is between 20 and 50, the user is considered to be under moderate stress ; and if the pNN50 is above 50, the user is classified as experiencing low stress [30].”
Arney, D. E., Zhang, Y., Kennedy-Metz, L. R., DIAS, R. D., Goldman, J. M., & Zenati, M. A. (2023) · Sensors · doi:10.3390/s23083890 · Cited by 9
“The LF/HF ratio thus reflects an input from both branches of the ANS and, given their respective oscillation frequencies and generally slower sympathetic responsiveness, requires a minimum time window of one minute of data to discriminate between high and low arousal states accurately [18], and to perform on-line proc…”
BackgroundMeyers, E., Alves, M., Teugels, A., & Torta, D. M. E. (2023) · Journal of Pain · doi:10.1016/j.jpain.2023.05.016 · Cited by 9
Qian, L., Zeng, X., Liu, X., & Peng, L. (2024) · Journal of Asian Architecture and Building Engineering · doi:10.1080/13467581.2024.2342856 · Cited by 9
“The physiological data points were preprocessed using Ergo-LAB software (as shown in Table 3) (Salahuddin et al. 2007).”
Brabant, O., Solati, S., Letulė, N., Liarmakopoulou, O., & Erkkilä, J. (2017) · Nordic Journal of Music Therapy · doi:10.1080/08098131.2016.1277253 · Cited by 12
Virtual Nature Environments Based on Fractal Geometry for Optimizing Restorative Effects
van Almkerk, M., & Huisman, G. (2018) · Electronic workshops in computing · doi:10.14236/ewic/hci2018.55 · Cited by 10
“[27] showed that HRV can be calculate reasonably accurately using this method in short time periods - i.”
MethodHalamová, J., Kanovský, M., & Koróniová, J. (2019) · Adaptive Human Behavior and Physiology · doi:10.1007/s40750-019-00122-3 · Cited by 9
“Ultra-short heart rate variability (HRV) was measured for 30 s (Salahuddin et al. 2007) of each relaxation baseline and of the self-critical, self-compassionate and self-protective imagery components, and RMSSD was computed separately for each 30-s episode.”
BackgroundMethodHeart Rate Variability reveals the fight between racially biased and politically correct behaviour
Palma, M. D., Arcangeli, E., Lattanzi, D., Gabbiadini, A., Gallucci, M., Cuppini, R., Minelli, A., & Berlingeri, M. (2019) · Scientific Reports · doi:10.1038/s41598-019-47888-w · Cited by 9
Effects of Working Memory Demand on Performance and Mental Stress During the Stroop Task
Petkar, H. C. (2011) · Spectrum Research Repository (Concordia University) · Cited by 11
Steinerová, K., Krause, A., Parker, S., & Seddon, Y. M. (2025) · Frontiers in Veterinary Science · doi:10.3389/fvets.2025.1518153 · Cited by 8
Baek, J. H., Grewal, S., Karam, K. A., Hanlon, E. R., Abohashem, S., Seligowski, A. V., Henry, M., Osborne, M. T., Nierenberg, A. A., & Tawakol, A. A. (2025) · Bipolar Disorders · doi:10.1111/bdi.13516 · Cited by 9
Distress detection in VR environment using Empatica E4 wristband and Bittium Faros 360
Medarević, J., Miljković, N., Stojmenova, K., & Sodnik, J. (2025) · Frontiers in Physiology · doi:10.3389/fphys.2025.1480018 · Cited by 8
Integrative Analysis of Open Datasets for Stress Prediction
Ladakis, I., Fotopoulos, D. T., & Chouvarda, I. (2025) · Journal of Medical and Biological Engineering · doi:10.1007/s40846-025-00958-z · Cited by 10
Schuller, B. W. (2016) · Human-computer interaction series · doi:10.1007/978-3-319-31413-6_4 · Cited by 8
Long and Short Durations of Binaural Beats Differently Affect Relaxation: A Study of HRV and BRUMS
Chockboondee, M., Jatupornpoonsub, T., Lertsukprasert, K., & Wongsawat, Y. (2023) · IEEE Access · doi:10.1109/access.2023.3303183 · Cited by 8
“stress [45], [49], [50], psychophysiological strain after exer-”
BackgroundShen, Y., Fang, Z., Zhang, T., Yu, F., Xu, Y., & Yang, L. (2025) · Frontiers in Physiology · doi:10.3389/fphys.2025.1535331 · Cited by 8
System for Body and Mind Monitoring in coaching process
Gharbi, A., Hey, S., Jatobá, L., Grossmann, U., Ottenbacher, J., Kuncoro, C. B. D., Stork, W., & Müller-Glaser, K. D. (2008) · IEEE/EMBS International Summer School on Medical Devices and Biosensors (ISSS-MDBS) · doi:10.1109/issmdbs.2008.4575024 · Cited by 8
“After signal conditioning (band pass filtering) and processing (detection of QRS complex), we can determine the HRV (Heart Rate Variability), which is considered to be a meaningful parameter in quantizing the stress level [1],[2],[3],[4].”
Method
Metadata
- Authors
- Salahuddin, L., Cho, J., Jeong, M. G., & Kim, D.
- Affiliations
- Samsung Electronics (South Korea) (KR)
- Venue
- 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Publisher
- IEEE
- Published
- 2007-08
- Volume
- 2007
- Pages
- 4656-4659
- ISSN
- 1557-170X (ISSN-L)
- OpenAlex
- W2162033213
- Cited by
- 374
- References
- 27
- Citations by year
- 2026: 19 · 2025: 32 · 2024: 34 · 2023: 35 · 2022: 42 · 2021: 35 · 2020: 24 · 2019: 40 · 2018: 26 · 2017: 17 · 2016: 13 · 2015: 10 · 2014: 9 · 2013: 13 · 2012: 6
- FWCI
- 10.21
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- Conference proceedings (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Samsung
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Physical Sciences › Computer Science › Artificial Intelligence › Emotion and Mood Recognition
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Keywords
- heart rate variability, psychological stress, mobile health monitoring, Stroop task, RR interval, RMSSD, pNN50, autonomic nervous system, stress measurement
- MeSH terms
- Autonomic Nervous System, Electrocardiography, Heart Rate, Humans, Monitoring, Physiologic, Stress, Psychological, Time Factors, Biosensing Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.