Optimal Operating Frequency in Wireless Power Transmission for Implantable Devices
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
This paper examines short-range wireless powering for implantable devices and shows that existing analysis techniques are not adequate to conclude the characteristics of power transfer efficiency over a wide frequency range. It shows, theoretically and experimentally, that the optimal frequency for power transmission in biological media can be in the GHz-range while existing solutions exclusively focus on the MHz-range. This implies that the size of the receive coil can be reduced by 10(4) times which enables the realization of fully integrated implantable devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gabriel, S., Lau, R. W., & Gabriel, C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/003 · Cited by 4,175 · cited 2×
“Furthermore, we consider the air-muscle interface and use parameters from [16] for the 4 Cole-Cole relaxation model, a variant of the Debye relaxation model.”
BackgroundMethod
Cited by
Wireless Power Transfer Strategies for Implantable Bioelectronics
Agarwal, K., Jegadeesan, R., Guo, Y.-X., & Thakor, N. V. (2017) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2017.2683520 · Cited by 540
Wireless power transfer techniques for implantable medical devices: a review
Khan, S. R., Pavuluri, S. K., Cummins, G., & Desmulliez, M. P. Y. (2020) · Sensors · doi:10.3390/s20123487 · Cited by 355
“The mid-field WPT scheme for biomedical devices was initially proposed for a 2 × 2 mm2square loop RX implant antenna operating at 915 MHz [13,37].”
BackgroundMethodInfluentialSuitability of NFC for Medical Device Communication and Power Delivery
Freudenthal, E., Herrera, D., Kautz, F., Natividad, C., Ogrey, A., Sipla, J., Sosa, A., Betancourt, C., & Estevez, L. (2007) · 2007 IEEE Dallas Engineering in Medicine and Biology Workshop · doi:10.1109/embsw.2007.4454171 · Cited by 29
“HF, UHF RFID (and potentially, MICS) offers significantly higher data rates than LF RFID, Recent research on shortrange magnetically coupled UHF indicates that highly efficient coupling through tissue is possible [13].”
BackgroundStudy of midfield wireless power transfer for implantable medical devices
Keerthi., K. S., Ilango., K., & Manjula., G. N. (2018) · 2018 2nd International Conference on Biomedical Engineering (IBIOMED) · doi:10.1109/ibiomed.2018.8534820 · Cited by 17
Metadata
- Authors
- Poon, A. S. Y., O'Driscoll, S., & Meng, T. H.
- Venue
- 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Publisher
- IEEE
- Published
- 2007-08
- Volume
- 2007
- Pages
- 5673-5678
- ISSN
- 1557-170X (ISSN-L)
- OpenAlex
- W2172018498
- Cited by
- 76
- References
- 1
- FWCI
- 6.54
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optimal Operating Frequency in Wireless Power Transmission for Implantable Devices. https://app.cochat.ai/papers/10.1109/iembs.2007.4353634
- The paper
- Poon, A. S. Y., O'Driscoll, S., & Meng, T. H. (2007). Optimal Operating Frequency in Wireless Power Transmission for Implantable Devices. 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. https://doi.org/10.1109/iembs.2007.4353634
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.