Flexible PDMS -based dry electrodes for electro-optic acquisition of ECG signals in wearable devices
Open accessThe DOI matches its Crossref record.
Abstract
We present a new type of flexible dry copper electrodes based on Polydimethylsiloxane (PDMS) coatings, requiring no electrical contact with the body. Tests were performed in order to evaluate the performance of these types of electrodes using electro-optic techniques, suitable for wearable devices. Conductive and insulated PDMS layers were fabricated through a spin coating process, reaching a thickness of 100µ. These layers were then deposited on top of a flexible copper sheet. In a first set of experiments PDMS-based electrodes were compared with Ag/AgCl pre-gelled electrodes, showing comparable performances and lower noise signals. In order to test the influence of electrode area into signal strength, different sizes were chosen: 10.14 cm(2), 17.55 cm(2), 25.3 cm(2) and 39 cm(2). The results have shown that the signal strength increases with electrode area. We have also tested the influence of PDMS conductivity in signal strength, by adding two types of nickel to the pre-polymer solution. PDMS conductive electrodes have shown slightly better performances, with amplitudes higher than 200mV, which is the maximum value recorded with PDMS insulated electrodes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
CNT/PDMS Composite Flexible Dry Electrodesfor Long-Term ECG Monitoring
Jung, H.-C., Moon, J.-H., Baek, D.-H., Lee, J.-H., Choi, Y.-Y., Hong, J.-S., & Lee, S.-H. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2190288 · Cited by 434
Dry electrodes for electrocardiography
Meziane, N., Webster, J. G., Attari, M., & Nimunkar, A. J. (2013) · Physiological Measurement · doi:10.1088/0967-3334/34/9/r47 · Cited by 288
Progress of new label-free techniques for biosensors: a review
Sang, S., Wang, Y., Feng, Q., Wei, Y., Ji, J., & Zhang, W. (2015) · Critical Reviews in Biotechnology · doi:10.3109/07388551.2014.991270 · Cited by 272
Capacitive Biopotential Measurement for Electrophysiological Signal Acquisition: A Review
Sun, Y., & Yu, X. B. (2016) · IEEE Sensors Journal · doi:10.1109/jsen.2016.2519392 · Cited by 174
Flexible Carbon Nanotube-Based Polymer Electrode for Long-Term Electrocardiographic Recording
Chi, M., Zhao, J., Dong, Y., & Wang, X. (2019) · Materials · doi:10.3390/ma12060971 · Cited by 68
Metadata
- Authors
- Fernandes, M. S., Lee, K. S., Ram, R. J., Correia, J. H., & Mendes, P. M.
- Venue
- 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology
- Publisher
- IEEE
- Published
- 2010-08
- Volume
- 2010
- Pages
- 3503-3506
- ISSN
- 2375-7477 (ISSN-L)
- OpenAlex
- W2079342144
- Cited by
- 43
- References
- 0
- FWCI
- 5.16
- Type
- conference paper
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Flexible PDMS -based dry electrodes for electro-optic acquisition of ECG signals in wearable devices. https://app.cochat.ai/papers/10.1109/iembs.2010.5627799
- The paper
- Fernandes, M. S., Lee, K. S., Ram, R. J., Correia, J. H., & Mendes, P. M. (2010). Flexible PDMS -based dry electrodes for electro-optic acquisition of ECG signals in wearable devices. 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology. https://doi.org/10.1109/iembs.2010.5627799
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.