CoChat

Flexible PDMS -based dry electrodes for electro-optic acquisition of ECG signals in wearable devices

Open access
Fernandes, M S, Lee, K S, Ram, R J, Correia, J H, Mendes, P M · 2010 · 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology
Cited by 43

The DOI matches its Crossref record.

Abstract

We present a new type of flexible dry copper electrodes based on Polydimethylsiloxane (PDMS) coatings, requiring no electrical contact with the body. Tests were performed in order to evaluate the performance of these types of electrodes using electro-optic techniques, suitable for wearable devices. Conductive and insulated PDMS layers were fabricated through a spin coating process, reaching a thickness of 100µ. These layers were then deposited on top of a flexible copper sheet. In a first set of experiments PDMS-based electrodes were compared with Ag/AgCl pre-gelled electrodes, showing comparable performances and lower noise signals. In order to test the influence of electrode area into signal strength, different sizes were chosen: 10.14 cm(2), 17.55 cm(2), 25.3 cm(2) and 39 cm(2). The results have shown that the signal strength increases with electrode area. We have also tested the influence of PDMS conductivity in signal strength, by adding two types of nickel to the pre-polymer solution. PDMS conductive electrodes have shown slightly better performances, with amplitudes higher than 200mV, which is the maximum value recorded with PDMS insulated electrodes.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/iembs.2010.5627799

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 43

Metadata

Authors
Fernandes, M. S., Lee, K. S., Ram, R. J., Correia, J. H., & Mendes, P. M.
Venue
2010 Annual International Conference of the IEEE Engineering in Medicine and Biology
Publisher
IEEE
Published
2010-08
Volume
2010
Pages
3503-3506
ISSN
2375-7477 (ISSN-L)
OpenAlex
W2079342144
Cited by
43
References
0
FWCI
5.16
Type
conference paper
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Flexible PDMS -based dry electrodes for electro-optic acquisition of ECG signals in wearable devices. https://app.cochat.ai/papers/10.1109/iembs.2010.5627799
The paper
Fernandes, M. S., Lee, K. S., Ram, R. J., Correia, J. H., & Mendes, P. M. (2010). Flexible PDMS -based dry electrodes for electro-optic acquisition of ECG signals in wearable devices. 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology. https://doi.org/10.1109/iembs.2010.5627799

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.