Ballistocardiography — A method worth revisiting
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
The field of ballistocardiography seems to be enjoying a recent resurgence, most notably through the development of novel technologies and signal processing methods for measurement and analysis. After the method almost vanished in the late 80's and 90's, it is reasonable to wonder what is different this time, and if the technique has now more chances of becoming what its pioneer always wanted - a widespread clinical tool. This paper is an effort to compare and contrast this novel wave of research (notably in the context of the authors' own work). It also suggests that the new approaches have several key differences with past embodiments that place them in a good position to address some specific issues such as cardiac resynchronization therapy device optimization or congestive heart failure monitoring. This optimism is largely fed by the recent technological advances enabling the measurement of the BCG unobtrusively, frequently, at home or in a hospital, and by a re-focus on monitoring and trending applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new method for long-term monitoring of the ballistocardiogram, heart rate, and respiration
Alihanka, J., Vaahtoranta, K., & Saarikivi, I. (1981) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.1981.240.5.r384 · Cited by 270
Robust ballistocardiogram acquisition for home monitoring
Inan, O. T., Etemadi, M., Wiard, R. M., Giovangrandi, L., & Kovacs, G. T. A. (2009) · Physiological Measurement · doi:10.1088/0967-3334/30/2/005 · Cited by 234 · cited 5×
“While the BCGs of healthy people can be rather well interpreted in light of physiologic events, BCGs of patients with cardiovascular diseases tend to be more difficult to interpret because of the complex interplay of the various internal forces.”
MethodInfluentialSelf-citationAdaptive Beat-to-Beat Heart Rate Estimation in Ballistocardiograms
Bruser, C., Stadlthanner, K., de Waele, S., & Leonhardt, S. (2011) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2011.2128337 · Cited by 219
Certain Molar Movements of the Human Body produced by the Circulation of the Blood.
Jw, G. (1877) · Europe PMC (PubMed Central) · Cited by 197
Certain Molar Movements of the Human Body produced by the Circulation of the Blood
Jw, G. (n.d.) · Europe PMC (PubMed Central) · Cited by 113
SCARBOROUGH, W. R., TALBOT, S. A., BRAUNSTEIN, J. R., RAPPAPORT, M. B., DOCK, W., SCARBOROUGH, W. R., HAMILTON, W. F., SMITH, J. E., NICKERSON, J. L., TALBOT, S. A., et al. (1956) · Circulation · doi:10.1161/01.cir.14.3.435 · Cited by 93
Ballistocardiography: An Appraisal of Technic, Physiologic Principles, and Clinical Value
GUBNER, R. S., Rodstein, M., & Ungerleider, H. E. (1953) · Circulation · doi:10.1161/01.cir.7.2.268 · Cited by 82
Studies with the ballistocardiograph in acute cardiac infarction and chronic angina pectoris
Starr, I., & Wood, F. C. (1943) · American Heart Journal · doi:10.1016/s0002-8703(43)90383-7 · Cited by 66 · cited 2×
“As highlighted in the introduction, a majority of the BCG work in the early days was focused on the diagnosis [3, 4], or even prognosis [21, 22] of cardiovascular diseases.”
BackgroundWiard, R. M., Inan, O. T., Argyres, B., Etemadi, M., Kovacs, G. T. A., & Giovangrandi, L. (2010) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-010-0722-y · Cited by 40 · cited 3×
“While the BCGs of healthy people can be rather well interpreted in light of physiologic events, BCGs of patients with cardiovascular diseases tend to be more difficult to interpret because of the complex interplay of the various internal forces.”
MethodSelf-citationInan, O. T., Etemadi, M., Wiard, R. M., Kovacs, G. T. A., & Giovangrandi, L. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5333709 · Cited by 37 · cited 3×
“While the BCGs of healthy people can be rather well interpreted in light of physiologic events, BCGs of patients with cardiovascular diseases tend to be more difficult to interpret because of the complex interplay of the various internal forces.”
MethodSelf-citationMandelbaum, H., & MANDELBAUM, R. A. (1953) · Circulation · doi:10.1161/01.cir.7.6.910 · Cited by 27
The potential of EMFi sensors in heart activity monitoring
Alametsä, J., Värri, A. O., Koivuluoma, M., & Barna, L. C. (2004) · Cited by 25
Measurement Precision in the Optimization of Cardiac Resynchronization Therapy
Turcott, R. G., Witteles, R. M., Wang, P. J., Vagelos, R. H., Fowler, M. B., & Ashley, E. A. (2010) · Circulation Heart Failure · doi:10.1161/circheartfailure.109.900076 · Cited by 25 · cited 1×
“It has been shown recently though that even echocardiographic data, thought to be the non-invasive „gold-standard‟, does not lead to reliable tuning [26].”
BackgroundProgress Towards a Physiological Cardiology: A Second Essay on the Ballistocardiogram
Starr, I. (1965) · Annals of Internal Medicine · doi:10.7326/0003-4819-63-6-1079 · Cited by 24
Three-dimensional ballistocardiographic responses to changes of posture
Soames, R. W., & Atha, J. (1982) · Clinical Physics and Physiological Measurement · doi:10.1088/0143-0815/3/3/001 · Cited by 23 · cited 2×
“very sensitive to disturbances of factors impacting cardiac dynamics [20].”
BackgroundWilliams, J. (2011) · Elsevier eBooks · doi:10.1016/b978-0-12-385185-7.00032-9 · Cited by 21 · cited 1×
“Inspired by Williams [16], our group has pioneered the use of modified weighing scales and developed several methods for the acquisition of high fidelity standing or sitting BCGs [17-19].”
MethodEstimation of central aortic forces in the ballistocardiogram under rest and exercise conditions
Wiard, R. M., Kim, H. J., Figueroa, C. A., Kovacs, G. T. A., Taylor, C. A., & Giovangrandi, L. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5333577 · Cited by 16 · cited 1×
“Computer Tomography (CT) models of aortas (where it is believed most of the force related to J wave is generated), we computed the forces at the fluid-solid interface [10].”
MethodSelf-citationBallistocardiography: past, present and future.
Goedhard, W. J. A. (1979) · PubMed · Cited by 12
Cited by
Ballistocardiography and Seismocardiography: A Review of Recent Advances
Inan, O. T., Migeotte, P.-F., Park, K.-S., Etemadi, M., Tavakolian, K., Casanella, R., Zanetti, J., Tank, J., Funtova, I., Prisk, G. K., et al. (2015) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2361732 · Cited by 775
“preliminarily corroborated by BCG findings as well [8].”
BackgroundResultSelf-citationBallistocardiogram signal processing: a review
Sadek, I., Biswas, J., & Abdulrazak, B. (2019) · Health Information Science and Systems · doi:10.1007/s13755-019-0071-7 · Cited by 216
“Fourth, there had not yet been the emergence of ultrasound and echocardiography methods that swiftly overhauled BCG and related methods for noninvasive cardiac and hemodynamic diagnostic [6].”
MethodAmbient and Unobtrusive Cardiorespiratory Monitoring Techniques
Bruser, C., Antink, C. H., Wartzek, T., Walter, M., & Leonhardt, S. (2015) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2015.2414661 · Cited by 175
“daily living [13], [14].”
Chen, S., Wu, N., Ma, L., Lin, S., Yuan, F., Xu, Z., Li, W., Wang, B., & Zhou, J. (2018) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b17723 · Cited by 170
Di Rienzo, M., Vaini, E., Castiglioni, P., Merati, G., Meriggi, P., Parati, G., Faini, A., & Rizzo, F. (2013) · Autonomic Neuroscience · doi:10.1016/j.autneu.2013.04.005 · Cited by 163
Metadata
- Authors
- Giovangrandi, L., Inan, O. T., Wiard, R. M., Etemadi, M., & Kovacs, G. T. A.
- Venue
- 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Publisher
- IEEE
- Published
- 2011-08
- Volume
- 2011
- Pages
- 4279-4282
- OpenAlex
- W1991113589
- Cited by
- 165
- References
- 18
- FWCI
- 15.60
- Type
- conference paper
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.