Cited by 119Non-Invasive Vital Sign MonitoringHeart Rate Variability and Autonomic ControlECG Monitoring and Analysis

Statistical approach for the detection of motion/noise artifacts in Photoplethysmogram

Selvaraj, N., Mendelson, Y., Shelley, K. H., Silverman, D. G., Chon, K. H.·2011·2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society

Abstract

Motion and noise artifacts (MNA) have been a serious obstacle in realizing the potential of Photoplethysmogram (PPG) signals for real-time monitoring of vital signs. We present a statistical approach based on the computation of kurtosis and Shannon Entropy (SE) for the accurate detection of MNA in PPG data. The MNA detection algorithm was verified on multi-site PPG data collected from both laboratory and clinical settings. The accuracy of the fusion of kurtosis and SE metrics for the artifact detection was 99.0%, 94.8% and 93.3% in simultaneously recorded ear, finger and forehead PPGs obtained in a clinical setting, respectively. For laboratory PPG data recorded from a finger with contrived artifacts, the accuracy was 88.8%. It was identified that the measurements from the forehead PPG sensor contained the most artifacts followed by finger and ear. The proposed MNA algorithm can be implemented in real-time as the computation time was 0.14 seconds using Matlab®.

Integrity signals

Registry

Crossref · 10.1109/iembs.2011.6091232

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Selvaraj et al. used kurtosis and Shannon Entropy to determine motion artifacts and achieved an accuracy of 88.8% in a laboratory setting.

    “Kurtosis and Shannon Entropy were the measurements used by Selvaraj et al. to determine motion artifacts, and they were able to perform an accuracy of 88.8% in a laboratory setting [174].”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Selvaraj, N., Mendelson, Y., Shelley, K. H., Silverman, D. G., & Chon, K. H.
Affiliations
  • Worcester Polytechnic Institute (US)
  • Yale University (US)
Venue
2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society
Publisher
IEEE
Published
2011-08
Volume
2011
Pages
4972-4975
ISSN
2375-7477 (ISSN-L)
OpenAlex
W2080146198
Cited by
119
References
7
Citations by year
2026: 11 · 2025: 11 · 2024: 13 · 2023: 9 · 2022: 16 · 2021: 14 · 2020: 11 · 2019: 15 · 2018: 5 · 2017: 5 · 2016: 5 · 2015: 2 · 2014: 1 · 2013: 1
FWCI
1.35
Type
conference paper
Language
en
Open access
closed
Locations
  • Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
Keywords
photoplethysmogram, motion artifact detection, kurtosis, Shannon entropy, vital signs monitoring, real-time monitoring, signal quality assessment
MeSH terms
Algorithms, Data Interpretation, Statistical, Diagnosis, Computer-Assisted, Humans, Movement, Oxygen, Sensitivity and Specificity, Reproducibility of Results, Artifacts, Photoplethysmography

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review