The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
A Voltage-Based Approach Without Extra Hardware for Open-Circuit Fault Diagnosis in Closed-Loop PWM AC Regenerative Drives
Abstract
The widespread use of electric drives has led to an increasing interest in their condition monitoring and fault diagnostics. With respect to power-switch open-circuit fault diagnosis, the majority of the proposed voltage-based approaches require additional hardware, increasing the system cost. As a result, industry acceptance may be low. This paper proposes a new voltage-based approach-without additional sensors-for open-circuit fault diagnosis in closed-loop controlled pulsewidth-modulation (PWM) ac voltage source converters, by using the information contained in the reference voltages available from the control system. The robustness against false alarms of the proposed technique is improved by employing a voltage observer, in order to estimate the actual converter voltages. It has been proven that the algorithm is insensitive to parameter errors; thus, its effectiveness is not compromised. In order to assess the applicability of the diagnostic technique, it is integrated into the control system of a permanent-magnet-synchronous-machine drive, with regenerative capabilities, together with three of the most widely used PWM control strategies: hysteresis current control, direct torque control, and space vector modulation. The technique performance is analyzed in detail by means of several experimental results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Condition Monitoring for Device Reliability in Power Electronic Converters: A Review
Yang, S., Xiang, D., Bryant, A., Mawby, P., Ran, L., & Tavner, P. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2049377 · Cited by 1,278 · cited 1×
“[1], [2] where such faults are attributed to 60% of the power device failures (26% of printed circuit board failures, 21% of semiconductor failures, and 13% of solder failures).”
BackgroundEstima, J. O., & Marques Cardoso, A. J. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2188877 · Cited by 377 · cited 1×
“values was suggested in [13], performing a quick diagnosis by means of a simple algorithm.”
MethodSelf-citation
Research works printed but not linked: 25
- abramik, 2003, A diagnostic method for on-line fault detection and localization in VSI-fed ac drives, Proc Eur Conf Power Electron Appl, 8
- 10.1109/TIE.2009.2023640 · DOI · Paper page
- 10.1109/TIA.2011.2168800 · DOI · Paper page
- 10.1109/DEMPED.2011.6063654 · DOI
- 10.1109/TIE.2012.2207655 · DOI · Paper page
- 10.1109/TPEL.2003.809351 · DOI · Paper page
- 10.1109/TIE.2008.2005244 · DOI · Paper page
- 10.1109/TPEL.2010.2052472 · DOI · Paper page
- 10.1049/iet-epa.2011.0315 · DOI
- mendes, 1998, voltage source inverter fault diagnosis in variable speed ac drives, by park's vector approach, Seventh International Conference on Power Electronics and Variable Speed Drives (IEE Conf Publ No 456), 538, 10.1049/cp:19980607 · DOI
- 10.1109/WEMDCD.2013.6525187 · DOI
- 10.1109/TIA.2011.2124436 · DOI · Paper page
- 10.1109/TEC.2005.847961 · DOI · Paper page
- 10.1109/IEMDC.1999.769220 · DOI · Paper page
- 10.1109/28.739017 · DOI · Paper page
- 10.1109/TIE.2007.911951 · DOI · Paper page
- 10.1109/ICELMACH.2010.5608044 · DOI
- 10.1049/iet-rpg.2008.0060 · DOI · Paper page
- 10.1109/TPEL.2012.2212916 · DOI · Paper page
- 10.1109/TIE.2010.2098355 · DOI · Paper page
- 10.1109/ICElMach.2012.6350216 · DOI
- 10.1109/28.273627 · DOI · Paper page
- 10.1109/TIE.2010.2047829 · DOI · Paper page
- 10.1109/TIA.2004.834049 · doi:10.1109/tia.2004.834049
- 10.1109/TPEL.2003.818833 · doi:10.1109/tpel.2003.818833
Cited by
A Data-Driven Fault Diagnosis Methodology in Three-Phase Inverters for PMSM Drive Systems
Cai, B., Zhao, Y., Liu, H., & Xie, M. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2608842 · Cited by 471
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
“The literature review shows that the open-circuit FDD methods may be classified as current signatures [254]–[260], [267]-[272] and voltage signatures based methods [261]– [264], [273].”
BackgroundMethodInfluentialAdaptive Fuzzy Control of Strict-Feedback Nonlinear Time-Delay Systems With Unmodeled Dynamics
Yin, S., Shi, P., & Yang, H. (2016) · IEEE Transactions on Cybernetics · doi:10.1109/tcyb.2015.2457894 · Cited by 305
Jlassi, I., Estima, J. O., El Khil, S. K., Bellaaj, N. M., & Cardoso, A. J. M. (2017) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2016.2616398 · Cited by 284
“shows that they may be classified as current signatures [12]– [20], [22]–[25], [30], [33]–[36] and voltage signatures based methods [26]–[29], [31], [32].”
BackgroundMethodSelf-citationModel-Based Fault Detection and Identification for Switching Power Converters
Poon, J., Jain, P., Konstantakopoulos, I. C., Spanos, C., Panda, S. K., & Sanders, S. R. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2541342 · Cited by 257
Metadata
- Authors
- Freire, N. M. A., Estima, J. O., & Cardoso, A. J. M.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2014-09
- Volume
- 61
- Issue
- 9
- Pages
- 4960-4970
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W1970115563
- Cited by
- 167
- References
- 2
- FWCI
- 8.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Voltage-Based Approach Without Extra Hardware for Open-Circuit Fault Diagnosis in Closed-Loop PWM AC Regenerative Drives. https://app.cochat.ai/papers/10.1109/tie.2013.2279383
- The paper
- Freire, N. M. A., Estima, J. O., & Cardoso, A. J. M. (2014). A Voltage-Based Approach Without Extra Hardware for Open-Circuit Fault Diagnosis in Closed-Loop PWM AC Regenerative Drives. IEEE Transactions on Industrial Electronics. https://doi.org/10.1109/tie.2013.2279383
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.