The Black Falcon: a teleoperated surgical instrument for minimally invasive surgery
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
This paper presents the Black Falcon, an eight degree-of-freedom teleoperator slave with a dextrous wrist for minimally invasive surgery (MIS). We show how teleoperation can address several key problems in MIS by increasing dexterity and degrees of freedom, by giving the surgeon some force feedback to feel instrument-tissue interactions and by eliminating geometric discrepancies between actual and observed tool motions. We discuss relevant design constraints, summarize the mechanism design and give data showing the quality of force reflection achieved. We demonstrate suturing along arbitrarily oriented suture lines in animal tissue, a task essentially impossible using current instruments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The PHANToM Haptic Interface: A Device for Probing Virtual Objects
Massie, T. H., & Salisbury, J. K. (1994) · Dynamic Systems and Control: Volume 1 — Control Theory/Methodology; Robust Control; Applied Nonlinear Control Systems; QFT Designs in Industrial, Government, Academic Settings; Robot Control; Impedance Planning for Robotics; Haptic Interfaces for Virtual Environment/Teleoperator Systems; Intelligent Control Systems; Intelligent Process Control; Neural Networks · doi:10.1115/imece1994-0452 · Cited by 1,372
Self-citationA telerobotic assistant for laparoscopic surgery
Taylor, R. H., Funda, J., Eldridge, B., Gomory, S., Gruben, K., LaRose, D., Talamini, M., Kavoussi, L., & Anderson, J. (1995) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.391776 · Cited by 392
Telepresence surgery demonstration system
Hill, J. W., Green, P. S., Jensen, J. F., Gorfu, Y., & Shah, A. (2002) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.1994.350942 · Cited by 75
(1989) · Choice Reviews Online · doi:10.5860/choice.27-0955 · Cited by 55
Triantafyllopoulos, K. (2021) · Springer texts in statistics · doi:10.1007/978-3-030-76124-0_8 · Cited by 15
Cited by
Bilateral teleoperation: An historical survey
Hokayem, P. F., & Spong, M. W. (2006) · Automatica · doi:10.1016/j.automatica.2006.06.027 · Cited by 1,671
The Intuitive/sup TM/ telesurgery system: overview and application
Guthart, G. S., & Salisbury, J. K. (2002) · Proceedings 2000 ICRA. Millennium Conference. IEEE International Conference on Robotics and Automation. Symposia Proceedings (Cat. No.00CH37065) · doi:10.1109/robot.2000.844121 · Cited by 920
Self-citationHe, Q., Wang, Z., Wang, Y., Minori, A., Tolley, M. T., & Cai, S. (2019) · Science Advances · doi:10.1126/sciadv.aax5746 · Cited by 564
Methods for haptic feedback in teleoperated robot‐assisted surgery
Okamura, A. M. (2004) · Industrial Robot: An International Journal · doi:10.1108/01439910410566362 · Cited by 493
Force Feedback Plays a Significant Role in Minimally Invasive Surgery: Results and Analysis
Tholey, G., Desai, J. P., & Castellanos, A. E. (2005) · Annals of Surgery · doi:10.1097/01.sla.0000149301.60553.1e · Cited by 330
Metadata
- Authors
- Madhani, A. J., Niemeyer, G., & Salisbury, J. K.
- Venue
- Proceedings. 1998 IEEE/RSJ International Conference on Intelligent Robots and Systems. Innovations in Theory, Practice and Applications (Cat. No.98CH36190)
- Publisher
- IEEE
- Published
- 2002-11-27
- Volume
- 2
- Pages
- 936-944
- OpenAlex
- W2114428836
- Cited by
- 291
- References
- 5
- FWCI
- 21.69
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.