Design and implementation of active error canceling in hand-held microsurgical instrument
The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
Presents the development and. initial experimental results of the first prototype of Micron, an active hand-held instrument to sense and compensate physiological tremor and other unwanted movement during vitreoretinal microsurgery. The instrument incorporates six inertial sensors, allowing the motion of the tip to be computed. The motion captured is processed to discriminate between desired and undesired components of motion. Tremor canceling is implemented via the weighted-frequency Fourier linear combiner (WFLC) algorithm, and compensation of non-tremorous error via a neural network technique is being investigated. The instrument tip is attached to a three-degree-of-freedom parallel manipulator with piezoelectric actuation. The actuators move the tool tip in opposition to the tremor, thereby suppressing the erroneous motion. Motion canceling experiments with oscillatory motions in the frequency band of physiological tremor show that Micron is able to reduce error amplitude by 45.3% in 1-D tests and 37.2% in 3-D tests.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Steady-Hand Robotic System for Microsurgical Augmentation
Taylor, R., Jensen, P., Whitcomb, L., Barnes, A., Kumar, R., Stoianovici, D., Gupta, P., Wang, Z., Dejuan, E., & Kavoussi, L. (1999) · The International Journal of Robotics Research · doi:10.1177/02783649922067807 · Cited by 528
Adaptive cancelling of physiological tremor for improved precision in microsurgery
Riviere, C. N., Rader, R. S., & Thakor, N. V. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.686791 · Cited by 260
Self-citationDecoupled extended Kalman filter training of feedforward layered networks
Puskorius, G. V., & Feldkamp, L. A. (2002) · IJCNN-91-Seattle International Joint Conference on Neural Networks · doi:10.1109/ijcnn.1991.155276 · Cited by 229
A teleoperated microsurgical robot and associated virtual environment for eye surgery
Hunter, I. W., Doukoglou, T. D., Lafontaine, S. R., Charette, P. G., Jones, L. A., Sagar, M. A., Mallinson, G. D., & Hunter, P. J. (1993) · Presence: Teleoperators and Virtual Environments · doi:10.1162/pres.1993.2.4.265 · Cited by 164
Physiologic tremor and microsurgery
Harwell, R. C., & Ferguson, R. L. (1983) · Microsurgery · doi:10.1002/micr.1920040310 · Cited by 131
Weiss, J. N. (1998) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(98)00086-5 · Cited by 100
A Study of Surgical Approaches to Retinal Vascular Occlusions
Tang, W. M. (2000) · Archives of Ophthalmology · doi:10.1001/archopht.118.1.138 · Cited by 84
ERGONOMICS APPLIED TO THE PRACTICE OF MICROSURGERY1
Patkin, M. (1977) · Australian and New Zealand Journal of Surgery · doi:10.1111/j.1445-2197.1977.tb04297.x · Cited by 80
A study of instrument motion in retinal microsurgery
Riviere, C. N., & Jensen, P. S. (2002) · Proceedings of the 22nd Annual International Conference of the IEEE Engineering in Medicine and Biology Society (Cat. No.00CH37143) · doi:10.1109/iembs.2000.900667 · Cited by 70
Self-citationAn Active Hand-Held Instrument for Enhanced Microsurgical Accuracy
Ang, W. T., Riviere, C. N., & Khosla, P. K. (2000) · Lecture Notes in Computer Science · doi:10.1007/978-3-540-40899-4_91 · Cited by 52
Self-citation
Cited by
Toward active tremor canceling in handheld microsurgical instruments
Riviere, C. N., Ang, W. T., & Khosla, P. K. (2003) · IEEE Transactions on Robotics and Automation · doi:10.1109/tra.2003.817506 · Cited by 245
Self-citationFirst-in-human study of the safety and viability of intraocular robotic surgery
Edwards, T. L., Xue, K., Meenink, H. C. M., Beelen, M. J., Naus, G. J. L., Simunovic, M. P., Latasiewicz, M., Farmery, A. D., de Smet, M. D., & MacLaren, R. E. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0248-4 · Cited by 231
Physiological tremor amplitude during retinal microsurgery
Singh, S. P. N., & Riviere, C. N. (2002) · Proceedings of the IEEE 28th Annual Northeast Bioengineering Conference (IEEE Cat. No.02CH37342) · doi:10.1109/nebc.2002.999520 · Cited by 131
Self-citationAng, W. T., Khosla, P. K., & Riviere, C. N. (2004) · 2003 IEEE International Conference on Robotics and Automation (Cat. No.03CH37422) · doi:10.1109/robot.2003.1241852 · Cited by 66
Self-citation
Metadata
- Authors
- Ang, W. T., Riviere, C. N., & Khosla, P. K.
- Venue
- Proceedings 2001 IEEE/RSJ International Conference on Intelligent Robots and Systems. Expanding the Societal Role of Robotics in the the Next Millennium (Cat. No.01CH37180)
- Publisher
- IEEE
- Published
- 2002-11-13
- Volume
- 2
- Pages
- 1106-1111
- OpenAlex
- W2138765416
- Cited by
- 52
- References
- 12
- FWCI
- 7.47
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Design and implementation of active error canceling in hand-held microsurgical instrument. https://app.cochat.ai/papers/10.1109/iros.2001.976316
- The paper
- Ang, W. T., Riviere, C. N., & Khosla, P. K. (2002). Design and implementation of active error canceling in hand-held microsurgical instrument. Proceedings 2001 IEEE/RSJ International Conference on Intelligent Robots and Systems. Expanding the Societal Role of Robotics in the the Next Millennium (Cat. No.01CH37180). https://doi.org/10.1109/iros.2001.976316
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.