A Continuous Respiratory Monitoring System Using Ultrasound Piezo Transducer
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
Prolonged monitoring of breathing under different physical conditions is important in many applications for personal health tracking or in hospitals. Ultrasound technology has been used widely for imaging and diagnosis of the human body. In this work, we introduce the use of ultrasound for human respiratory monitoring. The proposed system measures the respiration rate by capturing ultrasound reflections from heart and surrounding organ motions due to the breathing. This system is based on ultrasound B-mode to measure the Time Of Flight (TOF), amplitude and phase of reflected ultrasound signals generated by piezo sensors working at 1 MHz. Experimental results show that the system can obtain respiratory signal with an accuracy of 89% as compared to a SPR-BTA spirometer. A prototype is designed with low complexity hardware, delivering 89% accuracy of the obtained respiratory signal in comparison to a SPR-BTA spirometer.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Ultrasound sensors can be used to detect body movement and breathing patterns during sleep54,69,70.”
From The future of sleep health: a data-driven revolution in sleep science and medicine (2020) · cites this paper as [70]
Citations
Cites
A study of the motion and deformation of the heart due to respiration
McLeish, K., Hill, D. L. G., Atkinson, D., Blackall, J. M., & Razavi, R. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.804427 · Cited by 281 · cited 1×
“Moreover, respiratory motion of the heart on some patients shows [11], [12] that during inspiration, the heart moved inferiorly and underwent a craniodorsal rotation, and in few patients, they observed anterior movements as well.”
BackgroundPulse Oximetry in Pediatric Practice
Fouzas, S., Priftis, K. N., & Anthracopoulos, M. B. (2011) · Pediatrics · doi:10.1542/peds.2011-0271 · Cited by 219 · cited 2×
“Indirect methods, such as PPG sensors, are based on a consequence of an organ activity like oxygen level variation measurements due to the breathing [5].”
BackgroundMethodRespiratory Motion of the Heart From Free Breathing Coronary Angiograms
Shechter, G., Öztürk, C., Resar, J. R., & McVeigh, E. R. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.828676 · Cited by 159 · cited 1×
“Moreover, respiratory motion of the heart on some patients shows [11], [12] that during inspiration, the heart moved inferiorly and underwent a craniodorsal rotation, and in few patients, they observed anterior movements as well.”
BackgroundNewer methods of cardiac output monitoring
Mehta, Y. (2014) · World Journal of Cardiology · doi:10.4330/wjc.v6.i9.1022 · Cited by 113 · cited 1×
“Signals from piezo ultrasound sensors can extract human respiration patterns, heart rate and its variation (HRV), heart cycles (systole and diastole), wall motion abnormality in heart [7] and some other information such as cardiac output measurements [8].”
BackgroundAn Ultrasonic Contactless Sensor for Breathing Monitoring
Arlotto, P., Grimaldi, M., Naeck, R., & Ginoux, J.-M. (2014) · Sensors · doi:10.3390/s140815371 · Cited by 102 · cited 1×
“Recently reported is the contact-less breathing or heart rate tracking by low frequency ultrasound sensor [6].”
BackgroundBu, N., Ueno, N., & Fukuda, O. (2007) · 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2007.4352551 · Cited by 86 · cited 1×
“[3] reported a direct method based on aluminum nitride piezoelectric film that monitors the waveform.”
MethodBasic human anatomy : a regional study of human structure
O’Rahilly, R., & Müller, F. (1983) · Medical Entomology and Zoology · Cited by 76
Fekr, A. R., Radecka, K., & Zilic, Z. (2015) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2015.2445783 · Cited by 61 · cited 1×
“Another example of a direct method is chest and abdomen movements analysis using accelerometer sensors [4].”
MethodVariation in Diaphragm Position and Shape in Adults With Normal Pulmonary Functiona
Suwatanapongched, T., Gierada, D. S., Slone, R. M., Pilgram, T. K., & Tuteur, P. G. (2003) · CHEST Journal · doi:10.1378/chest.123.6.2019 · Cited by 59 · cited 1×
“Circumference of the normal adult rib cage expands by 3 to 5 cm during inhalation [10].”
BackgroundEvaluation of the Skin-To-Heart Distance in the Standing Adult by Two-Dimensional Echocardiography
Rahko, P. S. (2008) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2007.10.027 · Cited by 52 · cited 1×
“On the other hand, the external intercostal muscles are most significant in respiration, having fibres that are angled obliquely downward and forward from rib to rib [13].”
Background
Cited by
The future of sleep health: a data-driven revolution in sleep science and medicine
Perez-Pozuelo, I., Zhai, B., Palotti, J., Mall, R., Aupetit, M., Garcia-Gomez, J. M., Taheri, S., Guan, Y., & Fernandez-Luque, L. (2020) · npj Digital Medicine · doi:10.1038/s41746-020-0244-4 · Cited by 311
Contact and Remote Breathing Rate Monitoring Techniques: A Review
Ali, M., Elsayed, A., Mendez, A., Savaria, Y., & Sawan, M. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3072607 · Cited by 114
“A wearable ultrasound-based breathing monitoring system [55].”
Unobtrusive Sleep Monitoring Using Cardiac, Breathing and Movements Activities: An Exhaustive Review
Matar, G., Lina, J., Carrier, J., & Kaddoum, G. (2018) · IEEE Access · doi:10.1109/access.2018.2865487 · Cited by 80
Shahshahani, A., Laverdière, C., Bhadra, S., & Žilić, Ž. (2018) · Sensors · doi:10.3390/s18082617 · Cited by 40
“In the previous work [33,38], the transducer was operating at 1 MHz, and the piezo ringing effect period masked reflected signals from near objects.”
BackgroundMethodSelf-citationShahshahani, A., Žilić, Ž., & Bhadra, S. (2019) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2019.2912407 · Cited by 25
“A preliminary evaluation of the proposed system was done before [26].”
Self-citationAnnabestani, M., Esmaeili-Dokht, P., Nejad, S. K., & Fardmanesh, M. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3053211 · Cited by 21
“into a non-conductive silicone matrix [10], a sensor based on ultrasound piezo transducers [11], and a skin-mountable”
MethodNew Paths in Respiratory Sleep Medicine
Penzel, T., Dietz-Terjung, S., Woehrle, H., & Schöbel, C. (2021) · Sleep Medicine Clinics · doi:10.1016/j.jsmc.2021.08.006 · Cited by 13
Complete Cardiorespiratory Monitoring via Wearable Ultra Low Power Ultrasound
Vostrikov, S., Benini, L., & Cossettini, A. (2023) · IEEE International Ultrasonics Symposium · doi:10.1109/ius51837.2023.10307398 · Cited by 8
“B-mode imaging has also been used by Shahshahani et al. [10] for RR, by measuring the reflections from heart and surrounding organ motions due to the breathing [10].”
MethodForce-Sensing-Based Unobtrusive System for Awakening and Respiration Rate Analysis During Sleep
Park, S., Choi, H.-H., Yang, H. C., Yoon, J., & Shin, H. (2018) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2883716 · Cited by 9
“[11], ultrasonic piezo transducer for capturing ultrasound reflections from heart and surrounding organ motions due to the breathing [12], and Doppler rader for respiration monitoring [13].”
MethodA 171µW PPG-based Vitals Monitoring SoC for Asthmatic Patients
Minto, S., Saadeh, A., & Saadeh, W. (2022) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas54905.2022.9948619 · Cited by 5
“Moreover, the previous works were focusing on extracting one or a few of these vital signs [5], [6], [8], [9].”
BackgroundMethodAnnabestani, M., Mirzaei, I., Esmaeili-Dokht, P., & Fardmanesh, M. (2019) · National and International Iranian Conference on Biomedical Engineering (ICBME) · doi:10.1109/icbme49163.2019.9030397 · Cited by 5
“There are some reports in which a soft-piezo based sensor was used for spirometry devices [5-7], but it is the first time that an Ionic polymer-based soft sensor is used for this purpose.”
BackgroundDesign and Implementation of Low-Cost Respiratory Rate Measurement Device
Troyee, T. G., Gani, M. M., & Hasan, M. (2023) · Arabian Journal for Science and Engineering · doi:10.1007/s13369-023-08533-x · Cited by 5
“Shahshahani et al. proposed ultrasound B mode is used to measure the reflections made due to heart and other organ movement during the respiration cycle where they found 89% accuracy with respect to SPR-BTA spirome-ter[10].”
Gunaratne, P. N., Tamura, H., Yoshida, C., Sakurai, K., Tanno, K., Takahashi, N., & Nagata, J. (2019) · Moratuwa Engineering Research Conference (MERCon) · doi:10.1109/mercon.2019.8818763 · Cited by 4
“Such systems based on wearable device approach directly acquire measures on pressure fluctuations or chest muscle displacements, induced by breathing and heartbeat using MEMS based sensor systems [3], piezo transducers [4], chemical sensors based on polymer composites [5] or intelligent electrodes [6].”
MethodA 385μW Photoplethysmography-based Vitals Monitoring SoC with 110dB Current-to-Digital Converter
Minto, S., Salman, S., & Saadeh, W. (2022) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas48785.2022.9937795 · Cited by 5
“The work in [5] measured the RR by detecting ultrasound reflections from”
MethodAmbient Sleep Quality Analysis with a Machine Learning Model
Bagci, M. F., Nguyen, T. Q., & Öztürk, Y. (2023) · IEEE International Conference on Acoustics, Speech, and Signal Processing Workshops (ICASSPW) · doi:10.1109/icasspw59220.2023.10193407 · Cited by 6
“Radar [9] [10] and ultrasound based solutions [11] [12] are other examples of active ambient systems.”
BackgroundDesign of MEMS based Capacitive Pressure Sensor to Monitor the Respiratory Conditions of Patients
Shameem, S., Suresh, N., Kasmira, K., Yeswanth, P., Naveen, B., & Vineetha, K. V. (2019) · International Conference on Electrical, Electronics, Communication, Computer and Optimization Techniques (ICEECCOT) · doi:10.1109/iceeccot46775.2019.9114710 · Cited by 2
“Continuous monitoring of breathing under different physical conditions plays a vital role in hospitals to determine a person’s condition [2].”
BackgroundRen, S., Wang, X., Cai, M., Shi, Y., Wang, T., & Luo, Z. (2024) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2024.3471822 · Cited by 1
Design of a Low-Cost Portable Device for Respiratory Rate and Vital Sign Monitoring
Akash, M. S. R., Bhuiyan, M. N. H., Hasan, M. R., Bhuiyan, M. R., Hasan, M. R., & Imam, H. (2024) · IEEE International Conference on Biomedical Engineering, Computer and Information Technology for Health (BECITHCON) · doi:10.1109/becithcon64160.2024.10962616 · Cited by 1
“[30] RF identification tags 86% - - Heavy-weight and low-cost Jung et al. [12] Accelerometers & PPG sensors 88.66% 195 - Low-cost Shahshahani et al. [11] Ultrasound piezo transducer 89% - - Light-weight and low-cost Park et al. [13] PPG sensor 91.05% 20 - Low-cost [Proposed System] Thermoelectric…”
InfluentialNeue Verfahren in der respiratorischen Schlafmedizin
Dietz-Terjung, S., Wildenauer, A., Eggert, T., Schulte, T., Braun, M., Sutharsan, S., Welsner, M., Straßburg, S., Schöbel, C., & Hienzsch, A. (2023) · Pneumo News · doi:10.1007/s15033-023-3560-y
Model Estimation & Quadrature-Point Controller Design: For driving ultrasound
Metz, J.-P. (., & Jaspers, J. (. (2023) · Research Repository (Delft University of Technology)
Metadata
- Authors
- Shahshahani, A., Bhadra, S., & Zilic, Z.
- Affiliations
- McGill University (CA)
- Venue
- 2018 IEEE International Symposium on Circuits and Systems (ISCAS)
- Publisher
- IEEE
- Published
- 2018-05
- Pages
- 1-4
- ISSN
- 0271-4302 (ISSN-L)
- OpenAlex
- W2802340031
- Semantic Scholar
- a2d0d174a08126e0dab94aa7f62396119eeaf2d5
- Cited by
- 19
- References
- 14
- Citations by year
- 2024: 2 · 2023: 4 · 2022: 2 · 2021: 3 · 2020: 1 · 2019: 4 · 2018: 3
- FWCI
- 6.03
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- IEEE International Symposium on Circuits and Systems proceedings (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Ultrasound in Clinical Applications
- Physical Sciences › Engineering › Mechanics of Materials › Ultrasonics and Acoustic Wave Propagation
- Keywords
- respiratory monitoring, respiratory rate measurement, B-mode ultrasound, time-of-flight, cardiac motion, personal health monitoring, low-cost hardware prototype
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.