A Continuous Respiratory Monitoring System Using Ultrasound Piezo Transducer
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
Prolonged monitoring of breathing under different physical conditions is important in many applications for personal health tracking or in hospitals. Ultrasound technology has been used widely for imaging and diagnosis of the human body. In this work, we introduce the use of ultrasound for human respiratory monitoring. The proposed system measures the respiration rate by capturing ultrasound reflections from heart and surrounding organ motions due to the breathing. This system is based on ultrasound B-mode to measure the Time Of Flight (TOF), amplitude and phase of reflected ultrasound signals generated by piezo sensors working at 1 MHz. Experimental results show that the system can obtain respiratory signal with an accuracy of 89% as compared to a SPR-BTA spirometer. A prototype is designed with low complexity hardware, delivering 89% accuracy of the obtained respiratory signal in comparison to a SPR-BTA spirometer.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Ultrasound sensors can be used to detect body movement and breathing patterns during sleep54,69,70.”
From The future of sleep health: a data-driven revolution in sleep science and medicine (2020) · cites this paper as [70]
Citations
Cites
A study of the motion and deformation of the heart due to respiration
McLeish, K., Hill, D. L. G., Atkinson, D., Blackall, J. M., & Razavi, R. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.804427 · Cited by 281 · cited 1×
“Moreover, respiratory motion of the heart on some patients shows [11], [12] that during inspiration, the heart moved inferiorly and underwent a craniodorsal rotation, and in few patients, they observed anterior movements as well.”
BackgroundPulse Oximetry in Pediatric Practice
Fouzas, S., Priftis, K. N., & Anthracopoulos, M. B. (2011) · Pediatrics · doi:10.1542/peds.2011-0271 · Cited by 219 · cited 2×
“Indirect methods, such as PPG sensors, are based on a consequence of an organ activity like oxygen level variation measurements due to the breathing [5].”
BackgroundMethodRespiratory Motion of the Heart From Free Breathing Coronary Angiograms
Shechter, G., Öztürk, C., Resar, J. R., & McVeigh, E. R. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.828676 · Cited by 159 · cited 1×
“Moreover, respiratory motion of the heart on some patients shows [11], [12] that during inspiration, the heart moved inferiorly and underwent a craniodorsal rotation, and in few patients, they observed anterior movements as well.”
BackgroundNewer methods of cardiac output monitoring
Mehta, Y. (2014) · World Journal of Cardiology · doi:10.4330/wjc.v6.i9.1022 · Cited by 113 · cited 1×
“Signals from piezo ultrasound sensors can extract human respiration patterns, heart rate and its variation (HRV), heart cycles (systole and diastole), wall motion abnormality in heart [7] and some other information such as cardiac output measurements [8].”
BackgroundAn Ultrasonic Contactless Sensor for Breathing Monitoring
Arlotto, P., Grimaldi, M., Naeck, R., & Ginoux, J.-M. (2014) · Sensors · doi:10.3390/s140815371 · Cited by 102 · cited 1×
“Recently reported is the contact-less breathing or heart rate tracking by low frequency ultrasound sensor [6].”
BackgroundBu, N., Ueno, N., & Fukuda, O. (2007) · 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2007.4352551 · Cited by 86 · cited 1×
“[3] reported a direct method based on aluminum nitride piezoelectric film that monitors the waveform.”
MethodBasic human anatomy : a regional study of human structure
O’Rahilly, R., & Müller, F. (1983) · Medical Entomology and Zoology · Cited by 76
Fekr, A. R., Radecka, K., & Zilic, Z. (2015) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2015.2445783 · Cited by 61 · cited 1×
“Another example of a direct method is chest and abdomen movements analysis using accelerometer sensors [4].”
MethodVariation in Diaphragm Position and Shape in Adults With Normal Pulmonary Functiona
Suwatanapongched, T., Gierada, D. S., Slone, R. M., Pilgram, T. K., & Tuteur, P. G. (2003) · CHEST Journal · doi:10.1378/chest.123.6.2019 · Cited by 59 · cited 1×
“Circumference of the normal adult rib cage expands by 3 to 5 cm during inhalation [10].”
BackgroundEvaluation of the Skin-To-Heart Distance in the Standing Adult by Two-Dimensional Echocardiography
Rahko, P. S. (2008) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2007.10.027 · Cited by 52 · cited 1×
“On the other hand, the external intercostal muscles are most significant in respiration, having fibres that are angled obliquely downward and forward from rib to rib [13].”
BackgroundSani, Z. A., Shalbaf, A., Behnam, H., & Shalbaf, R. (2014) · Journal of Imaging Informatics in Medicine · doi:10.1007/s10278-014-9722-z · Cited by 31 · cited 1×
“Signals from piezo ultrasound sensors can extract human respiration patterns, heart rate and its variation (HRV), heart cycles (systole and diastole), wall motion abnormality in heart [7] and some other information such as cardiac output measurements [8].”
BackgroundBai, Y., Li, W.-T., & Chen, Y.-W. (2010) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea.2010.5480222 · Cited by 30 · cited 1×
“The systems based on direct method are flow meters that use pressure transducer or even thermal and ultrasound flow meters [1], [2].”
MethodAraujo, G. A. L., Freire, R. C. S., Silva, J. F., de Oliveira, A. C., & Jaguaribe, E. F. (2004) · Conference proceedings - IEEE Instrumentation/Measurement Technology Conference · doi:10.1109/imtc.2004.1351149 · Cited by 28 · cited 1×
“The systems based on direct method are flow meters that use pressure transducer or even thermal and ultrasound flow meters [1], [2].”
MethodUltrasound sensors and its application in human heart rate monitoring
Shahshahani, A., Nafchi, D. R., & Žilić, Ž. (2017) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2017.8050899 · Cited by 7 · cited 2×
“The result is passed to an envelope detector and a Dynamic Average Threshold Crossing (D-ATC) block [14], which helps to reduce the digital signal processing effort by finding indexes of the sampled signals where the amplitude passes a threshold value in each record.”
BackgroundMethodSelf-citation
Cited by
The future of sleep health: a data-driven revolution in sleep science and medicine
Perez-Pozuelo, I., Zhai, B., Palotti, J., Mall, R., Aupetit, M., Garcia-Gomez, J. M., Taheri, S., Guan, Y., & Fernandez-Luque, L. (2020) · npj Digital Medicine · doi:10.1038/s41746-020-0244-4 · Cited by 311
Contact and Remote Breathing Rate Monitoring Techniques: A Review
Ali, M., Elsayed, A., Mendez, A., Savaria, Y., & Sawan, M. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3072607 · Cited by 114
“A wearable ultrasound-based breathing monitoring system [55].”
Unobtrusive Sleep Monitoring Using Cardiac, Breathing and Movements Activities: An Exhaustive Review
Matar, G., Lina, J., Carrier, J., & Kaddoum, G. (2018) · IEEE Access · doi:10.1109/access.2018.2865487 · Cited by 79
Shahshahani, A., Laverdière, C., Bhadra, S., & Žilić, Ž. (2018) · Sensors · doi:10.3390/s18082617 · Cited by 40
“In the previous work [33,38], the transducer was operating at 1 MHz, and the piezo ringing effect period masked reflected signals from near objects.”
BackgroundMethodSelf-citationShahshahani, A., Žilić, Ž., & Bhadra, S. (2019) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2019.2912407 · Cited by 25
“A preliminary evaluation of the proposed system was done before [26].”
Self-citation
Metadata
- Authors
- Shahshahani, A., Bhadra, S., & Zilic, Z.
- Affiliations
- McGill University (CA)
- Venue
- 2018 IEEE International Symposium on Circuits and Systems (ISCAS)
- Publisher
- IEEE
- Published
- 2018-05
- Pages
- 1-4
- ISSN
- 0271-4302 (ISSN-L)
- OpenAlex
- W2802340031
- Semantic Scholar
- a2d0d174a08126e0dab94aa7f62396119eeaf2d5
- Cited by
- 19
- References
- 14
- Citations by year
- 2024: 2 · 2023: 4 · 2022: 2 · 2021: 3 · 2020: 1 · 2019: 4 · 2018: 3
- FWCI
- 6.03
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- IEEE International Symposium on Circuits and Systems proceedings (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Ultrasound in Clinical Applications
- Physical Sciences › Engineering › Mechanics of Materials › Ultrasonics and Acoustic Wave Propagation
- Keywords
- respiratory monitoring, respiratory rate measurement, B-mode ultrasound, time-of-flight, cardiac motion, personal health monitoring, low-cost hardware prototype
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.