Ultra-fast DC-charge infrastructures for EV-mobility and future smart grids
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Nowadays Power Electronics (PE) is entering more and more in technology which traditionally belongs to different engineering disciplines. E-mobility is one of these. Power Electronics in fact imposes itself as an emerging technology to enhance sustainable mobility, addressing all the engineering aspects starting from energy distribution for charging purposes until energy transformation on board of the traction related vehicles. This paper in particular focuses on newly developed PE infrastructure technologies enabling fast battery charging processes. Depending on the battery and vehicle type, a recharge sufficient for a travel range of more than 100km in less than 10 min is readily achievable. As battery technologies continuously advance, recharging will become available with the speed and simplicity of a today's fuel stop. Two PE converter architectures for recharging infrastructure applications will be presented and discussed based on both low-frequency (LF) and high-frequency (HF) isolation requirements. Technical evaluation of the two different technologies will be addressed and presented, including a pro- and contra analysis. The impact on the grid is studied by means of simulation with the assumption of a dc fast charging station placed in a rural area in Sweden.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Design considerations for high-voltage high-power full-bridge zero-voltage-switched PWM converter
Sabate, J. A., Vlatkovic, V., Ridley, R. B., Lee, F. C., & Cho, B. H. (1990) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.1990.66420 · Cited by 1,015
Automotive DC-DC bidirectional converter made with many interleaved buck stages
Garcia, O., Zumel, P., de Castro, A., & Cobos, A. (2006) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.872379 · Cited by 405 · cited 1×
“Furthermore, the interleaved converter topology [1] offers advantages regarding the filter reduction due to the fundamental frequency been effectively multiplied by the number of phases.”
BackgroundIGBT turn-off losses for hard switching and with capacitive snubbers
Petterteig, A., Lode, J., & Undeland, T. M. (2002) · IEEE Industry Applications Society Annual Meeting (IAS) · doi:10.1109/ias.1991.178059 · Cited by 75
Cited by
Yilmaz, M., & Krein, P. T. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2212917 · Cited by 3,118
“protection systems for EV supply circuits [13].”
A review of energy sources and energy management system in electric vehicles
Tie, S. F., & Tan, C. W. (2013) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2012.11.077 · Cited by 1,463
Review of the Impact of Vehicle-to-Grid Technologies on Distribution Systems and Utility Interfaces
Yilmaz, M., & Krein, P. T. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2227500 · Cited by 1,024
“the standard for personnel protection systems for PEV supply circuits [87].”
BackgroundExtreme Fast Charging of Electric Vehicles: A Technology Overview
Tu, H., Feng, H., Srdic, S., & Lukic, S. (2019) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2019.2958709 · Cited by 898
Kumar, D., Zare, F., & Ghosh, A. (2017) · IEEE Access · doi:10.1109/access.2017.2705914 · Cited by 751
Metadata
- Authors
- Aggeler, D., Canales, F., Zelaya-De La Parra, H., Coccia, A., Butcher, N., & Apeldoorn, O.
- Venue
- 2010 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT Europe)
- Publisher
- IEEE
- Published
- 2010-10
- Pages
- 1-8
- OpenAlex
- W2080145054
- Cited by
- 274
- References
- 3
- FWCI
- 20.09
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.