A convolutional neural network based approach to QRS detection
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
In this paper we present a QRS detection algorithm based on pattern recognition as well as a new approach to ECG baseline wander removal and signal normalization. Each point of the zero-centred and normalized ECG signal is a QRS candidate, while a 1-D CNN classifier serves as a decision rule. Positive outputs from the CNN are clustered to form final QRS detections. The data is obtained from the 44 non-pacemaker recordings of the MIT-BIH arrhythmia database. Classifier was trained on 22 recordings and the remaining ones are used for performance evaluation. Our method achieves a sensitivity of 99.81% and 99.93% positive predictive value, which is comparable with most state-of-the-art solutions. This approach opens new possibilities for improvements in heartbeat classification as well as P and T wave detection problems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Real-Time QRS Detection Algorithm
Pan, J., & Tompkins, W. J. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325532 · Cited by 7,855 · cited 1×
“one being the Pan-Tompkins algorithm [27]), various neural network based approaches have been proposed as well [28]– [30].”
BackgroundThe impact of the MIT-BIH Arrhythmia Database
Moody, G. B., & Mark, R. G. (2001) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.932724 · Cited by 4,812
A comparison of the noise sensitivity of nine QRS detection algorithms
Friesen, G. M., Jannett, T. C., Jadallah, M. A., Yates, S. L., Quint, S. R., & Nagle, H. T. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.43620 · Cited by 1,043 · cited 1×
“Review and comparison of traditional QRS detection methods can be found in [5], while a more recent revision of QRS detection algorithms can be found in [6].”
BackgroundMelillo, P., Bracale, M., & Pecchia, L. (2011) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-10-96 · Cited by 328 · cited 2×
“Improvements in quality of automatic heartbeat detection are important for features that greatly benefit from accurate heartbeat localization, like measures derived from heart rate variability [1].”
Background
Cited by
IMPACT OF HUMAN DISASTERS AND COVID-19 PANDEMIC ON MENTAL HEALTH: POTENTIAL OF DIGITAL PSYCHIATRY
Laboratory for Interactive Simulation Systems, F. O. E. E. A. C., Cosic, K., Popovic, S., Laboratory for Interactive Simulation Systems, F. O. E. E. A. C., Sarlija, M., Laboratory for Interactive Simulation Systems, F. O. E. E. A. C., Kesedzic, I., & Laboratory for Interactive Simulation Systems, F. O. E. E. A. C. (2020) · Psychiatria Danubina · doi:10.24869/psyd.2020.25 · Cited by 294
Self-citationRundo, F., Conoci, S., Ortis, A., & Battiato, S. (2018) · Sensors · doi:10.3390/s18020405 · Cited by 143
“In [36,37] the recent approaches based on Deep Learning Algorithm and Convolutional Neural Networks have been used.”
MethodDeep Learning on 1-D Biosignals: a Taxonomy-based Survey
Ganapathy, N., Swaminathan, R., & Deserno, T. (2018) · Yearbook of Medical Informatics · doi:10.1055/s-0038-1667083 · Cited by 83
“Out of 10 papers using single lead ECG inputs, seven [19, 47, 49, 58–60, In general, the overall results were above 94% accuracy.”
ResultKesedzic, I., Sarlija, M., Bozek, J., Popovic, S., & Cosic, K. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2020.3038032 · Cited by 29
Metadata
- Authors
- Sarlija, M., Jurisic, F., & Popovic, S.
- Venue
- Proceedings of the 10th International Symposium on Image and Signal Processing and Analysis
- Publisher
- IEEE
- Published
- 2017-09
- Pages
- 121-125
- ISSN
- 1845-5921 (ISSN-L)
- OpenAlex
- W2766837055
- Cited by
- 56
- References
- 4
- FWCI
- 9.80
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.