Source Selection for Real-Time User Intent Recognition Toward Volitional Control of Artificial Legs
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Various types of data sources have been used to recognize user intent for volitional control of powered artificial legs. However, there is still a debate on what exact data sources are necessary for accurately and responsively recognizing the user's intended tasks. Motivated by this widely interested question, in this study we aimed to 1) investigate the usefulness of different data sources commonly suggested for user intent recognition and 2) determine an informative set of data sources for volitional control of prosthetic legs. The studied data sources included eight surface electromyography (EMG) signals from the residual thigh muscles of transfemoral (TF) amputees, ground reaction forces/moments from a prosthetic pylon, and kinematic measurements from the residual thigh and prosthetic knee. We then ranked and included data sources based on the usefulness for user intent recognition and selected a reduced number of data sources that ensured accurate recognition of the user's intended task by using three source selection algorithms. The results showed that EMG signals and ground reaction forces/moments were more informative than prosthesis kinematics. Nine to eleven of all the initial data sources were sufficient to maintain 95% accuracy for recognizing the studied seven tasks without missing additional task transitions in real time. The selected data sources produced consistent system performance across two experimental days for four recruited TF amputee subjects, indicating the potential robustness of the selected data sources. Finally, based on the study results, we suggested a protocol for determining the informative data sources and sensor configurations for future development of volitional control of powered artificial legs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new strategy for multifunction myoelectric control
Hudgins, B., Parker, P., & Scott, R. N. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.204774 · Cited by 2,149 · cited 1×
“Four commonly used EMG time-domain (TD) features [18] (mean absolute value, number of slope sign changes, waveform length,”
A robust, real-time control scheme for multifunction myoelectric control
Englehart, K., & Hudgins, B. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.813539 · Cited by 1,743 · cited 1×
“In order to make use of all of the streamed data for continuous decision making, the window increment (Δt) was required to be greater than or equal to the processing time (τ ) [21].”
Huang, H., Zhang, F., Hargrove, L. J., Dou, Z., Rogers, D. R., & Englehart, K. B. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2161671 · Cited by 542 · cited 5×
“Unlike previous design, in which we used offline cross validation to evaluate the interface [15], this study included a system-training protocol for quick calibration and”
InfluentialSelf-citation
Research works printed but not linked: 21
- 10.1109/TBME.2009.2034734 · DOI · Paper page
- 10.1001/jama.2011.465 · DOI
- 10.1109/TBME.2010.2070840 · DOI · Paper page
- 10.1109/TBME.2008.2003293 · DOI · Paper page
- 10.1115/1.3426266 · DOI · Paper page
- hale, 1990, Analysis of the swing phase dynamics and muscular effort of the above-knee amputee for varying prosthetic shank loads, Prosthet Orthot Int, 14, 125, 10.3109/03093649009080338 · doi:10.3109/03093649009080338
- 10.1109/IEMBS.2011.6090822 · DOI
- 10.1109/TNN.2003.816033 · DOI · Paper page
- 10.1177/0278364907084588 · DOI · Paper page
- 10.1053/apmr.2002.34605 · DOI
- 10.1682/JRRD.2008.09.0131 · doi:10.1682/jrrd.2008.09.0131
- 10.1016/j.neunet.2008.03.006 · DOI · Paper page
- 10.1111/j.1532-5415.1996.tb01415.x · DOI
- 10.1016/j.apmr.2007.11.005 · DOI · Paper page
- 2003, Actuated Leg Prosthesis for Above-Knee Amputees
- frey, 1998, Graphical Models for Machine Learning and Digital Communication, 10.7551/mitpress/3348.001.0001 · DOI · Paper page
- 10.1093/bioinformatics/btn145 · DOI
- 10.1142/S0219720005001004 · DOI · Paper page
- golub, 1999, Molecular classification of cancer: class discovery and class prediction by gene expression monitoring, Science, 286, 531, 10.1126/science.286.5439.531 · DOI · Paper page
- 10.1109/TPAMI.2005.159 · DOI · Paper page
- 10.1093/bioinformatics/17.suppl_1.S157 · DOI
Cited by
Toward higher-performance bionic limbs for wider clinical use
Farina, D., Vujaklija, I., Brånemark, R., Bull, A. M. J., Dietl, H., Graimann, B., Hargrove, L. J., Hoffmann, K.-P., Huang, H., Ingvarsson, T., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00732-x · Cited by 263
Self-citationActive lower limb prosthetics: a systematic review of design issues and solutions
Windrich, M., Grimmer, M., Christ, O., Rinderknecht, S., & Beckerle, P. (2016) · BioMedical Engineering OnLine · doi:10.1186/s12938-016-0284-9 · Cited by 272
Fleming, A., Stafford, N., Huang, S., Hu, X., Ferris, D. P., & Huang, H. (. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac1176 · Cited by 216
“Other feature/source reduction methods explored in lower-limb prosthesis control include sequential forward and backward selection and minimum-redundancy-maximum-relevance algorithms [78].”
BackgroundMethodInfluentialSelf-citationYoung, A. J., Kuiken, T. A., & Hargrove, L. J. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/5/056021 · Cited by 200
A review of current state-of-the-art control methods for lower-limb powered prostheses
Gehlhar, R., Tucker, M., Young, A. J., & Ames, A. D. (2023) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2023.03.003 · Cited by 131
Metadata
- Authors
- Zhang, F., & Huang, H.
- Venue
- IEEE Journal of Biomedical and Health Informatics
- Published
- 2013-09
- Volume
- 17
- Issue
- 5
- Pages
- 907-914
- ISSN
- 2168-2194 (ISSN-L)
- 2168-2208
- OpenAlex
- W2069316794
- Cited by
- 103
- References
- 3
- FWCI
- 1.74
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Source Selection for Real-Time User Intent Recognition Toward Volitional Control of Artificial Legs. https://app.cochat.ai/papers/10.1109/jbhi.2012.2236563
- The paper
- Zhang, F., & Huang, H. (2013). Source Selection for Real-Time User Intent Recognition Toward Volitional Control of Artificial Legs. IEEE Journal of Biomedical and Health Informatics. https://doi.org/10.1109/jbhi.2012.2236563
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.