CoChat

Source Selection for Real-Time User Intent Recognition Toward Volitional Control of Artificial Legs

Open access
Fan Zhang, He Huang · 2013 · IEEE Journal of Biomedical and Health Informatics
Cited by 103

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Various types of data sources have been used to recognize user intent for volitional control of powered artificial legs. However, there is still a debate on what exact data sources are necessary for accurately and responsively recognizing the user's intended tasks. Motivated by this widely interested question, in this study we aimed to 1) investigate the usefulness of different data sources commonly suggested for user intent recognition and 2) determine an informative set of data sources for volitional control of prosthetic legs. The studied data sources included eight surface electromyography (EMG) signals from the residual thigh muscles of transfemoral (TF) amputees, ground reaction forces/moments from a prosthetic pylon, and kinematic measurements from the residual thigh and prosthetic knee. We then ranked and included data sources based on the usefulness for user intent recognition and selected a reduced number of data sources that ensured accurate recognition of the user's intended task by using three source selection algorithms. The results showed that EMG signals and ground reaction forces/moments were more informative than prosthesis kinematics. Nine to eleven of all the initial data sources were sufficient to maintain 95% accuracy for recognizing the studied seven tasks without missing additional task transitions in real time. The selected data sources produced consistent system performance across two experimental days for four recruited TF amputee subjects, indicating the potential robustness of the selected data sources. Finally, based on the study results, we suggested a protocol for determining the informative data sources and sensor configurations for future development of volitional control of powered artificial legs.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/jbhi.2012.2236563

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Research works printed but not linked: 21

  1. 10.1109/TBME.2009.2034734 · DOI · Paper page
  2. 10.1001/jama.2011.465 · DOI
  3. 10.1109/TBME.2010.2070840 · DOI · Paper page
  4. 10.1109/TBME.2008.2003293 · DOI · Paper page
  5. 10.1115/1.3426266 · DOI · Paper page
  6. hale, 1990, Analysis of the swing phase dynamics and muscular effort of the above-knee amputee for varying prosthetic shank loads, Prosthet Orthot Int, 14, 125, 10.3109/03093649009080338 · doi:10.3109/03093649009080338
  7. 10.1109/IEMBS.2011.6090822 · DOI
  8. 10.1109/TNN.2003.816033 · DOI · Paper page
  9. 10.1177/0278364907084588 · DOI · Paper page
  10. 10.1053/apmr.2002.34605 · DOI
  11. 10.1682/JRRD.2008.09.0131 · doi:10.1682/jrrd.2008.09.0131
  12. 10.1016/j.neunet.2008.03.006 · DOI · Paper page
  13. 10.1111/j.1532-5415.1996.tb01415.x · DOI
  14. 10.1016/j.apmr.2007.11.005 · DOI · Paper page
  15. 2003, Actuated Leg Prosthesis for Above-Knee Amputees
  16. frey, 1998, Graphical Models for Machine Learning and Digital Communication, 10.7551/mitpress/3348.001.0001 · DOI · Paper page
  17. 10.1093/bioinformatics/btn145 · DOI
  18. 10.1142/S0219720005001004 · DOI · Paper page
  19. golub, 1999, Molecular classification of cancer: class discovery and class prediction by gene expression monitoring, Science, 286, 531, 10.1126/science.286.5439.531 · DOI · Paper page
  20. 10.1109/TPAMI.2005.159 · DOI · Paper page
  21. 10.1093/bioinformatics/17.suppl_1.S157 · DOI

Cited by

Metadata

Authors
Zhang, F., & Huang, H.
Venue
IEEE Journal of Biomedical and Health Informatics
Published
2013-09
Volume
17
Issue
5
Pages
907-914
ISSN
  • 2168-2194 (ISSN-L)
  • 2168-2208
OpenAlex
W2069316794
Cited by
103
References
3
FWCI
1.74
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.