Exploiting Wearable Goniometer Technology for Motion Sensing Gloves
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
This paper presents an innovative wearable kinesthetic glove realized with knitted piezoresistive fabric (KPF) sensor technology. The glove is conceived to capture hand movement and gesture by using KPF in a double-layer configuration working as angular sensors (electrogoniometers). The sensing glove prototype is endowed by three KPF goniometers, used to track flexion and extension movement of metacarpophalangeal joint of thumb, index, and middle fingers. The glove is devoted to the continuous monitoring of patients during their daily-life activities, in particular for stroke survivors during their rehabilitation. The prototype performances have been evaluated in comparison with an optical tracking system considered as a gold standard both for relieving static and dynamic posture and gesture of the hand. The introduced prototype has shown very interesting figures of merit. The angular error, evaluated through the standard Bland Altman analysis, has been estimated in ±3° which is slightly less accurate than commercial electrogoniometers. Moreover, a new conceptual prototype design, preliminary evaluated within this study, is presented and discussed in order to solve actual limitations in terms of number and type of sensor connections, avoiding mechanical constraints given by metallic inextensible wires and improving user comfort.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Postural Hand Synergies for Tool Use
Santello, M., Flanders, M., & Soechting, J. F. (1998) · The Journal of Neuroscience · doi:10.1523/jneurosci.18-23-10105.1998 · Cited by 1,215
Sensor Evaluation for Wearable Strain Gauges in Neurological Rehabilitation
Giorgino, T., Tormene, P., Lorussi, F., De Rossi, D., & Quaglini, S. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2019584 · Cited by 100
Self-citation
Cited by
Textile‐Based Strain Sensor for Human Motion Detection
Wang, J., Lu, C., & Zhang, K. (2020) · ENERGY & ENVIRONMENTAL MATERIALS · doi:10.1002/eem2.12041 · Cited by 294
Maceira-Elvira, P., Popa, T., Schmid, A.-C., & Hummel, F. C. (2019) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-019-0612-y · Cited by 265
Bairagi, S., Shahid-ul-Islam, Shahadat, M., Mulvihill, D. M., & Ali, W. (2023) · Nano Energy · doi:10.1016/j.nanoen.2023.108414 · Cited by 246
Smart Tactile Gloves for Haptic Interaction, Communication, and Rehabilitation
Ozioko, O., & Dahiya, R. (2022) · Advanced Intelligent Systems · doi:10.1002/aisy.202100091 · Cited by 233
Wearable Sensors for Monitoring Human Motion: A Review on Mechanisms, Materials, and Challenges
Homayounfar, S. Z., & Andrew, T. L. (2020) · SLAS TECHNOLOGY · doi:10.1177/2472630319891128 · Cited by 227
“A kinesthetic sensing glove embedded with three goniometers made of KPF in a double-layer configuration was also presented that was used to track patient hand posture in daily activities within ±3° compared with commercial goniometers.(16) Another solution to the rigidity and imprecision of commercial goniometers is o…”
MethodWearable E-Textile Technologies: A Review on Sensors, Actuators and Control Elements
Gonçalves, C., Ferreira da Silva, A., Gomes, J., & Simoes, R. (2018) · Inventions · doi:10.3390/inventions3010014 · Cited by 208
“All of the wearable e-textiles have battery requirements that must be fulfilled either by detachable batteries or by thin, flat, and flexible batteries that are able to survive washing, drying, ironing, and dry cleaning [14].”
BackgroundA Wearable Hand Rehabilitation System With Soft Gloves
Chen, X., Gong, L., Wei, L., Yeh, S.-C., Da Xu, L., Zheng, L., & Zou, Z. (2021) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2020.3010369 · Cited by 194
“For instance, knitted piezoresistive fabric sensors [30],”
The use of a finger-worn accelerometer for monitoring of hand use in ambulatory settings
Liu, X., Rajan, S., Ramasarma, N., Bonato, P., & Lee, S. I. (2019) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2018.2821136 · Cited by 39
“, amount of hand use) that could capture relevant information regarding the goaldirected use of the upper limb, which also has been suggested by other work in the field [14], [15].”
BackgroundPloderer, B., Fong, J., Klaic, M., Nair, S., Vetere, F., Cofré Lizama, L. E., & Galea, M. P. (2016) · JMIR Rehabilitation and Assistive Technologies · doi:10.2196/rehab.6182 · Cited by 22
“Related work shows the potential of capturing finger and wrist movements through sensors captured through gloves [33,34] or rings worn on the finger [12,16], which we aim to explore in subsequent phases of this research project.”
BackgroundHuman activity recognition via smart-belt in wireless body area networks
Zhu, Y., Yu, J., Hu, F., Li, Z., & Ling, Z. (2019) · International Journal of Distributed Sensor Networks · doi:10.1177/1550147719849357 · Cited by 9
Metadata
- Authors
- Carbonaro, N., Mura, G. D., Lorussi, F., Paradiso, R., De Rossi, D., & Tognetti, A.
- Venue
- IEEE Journal of Biomedical and Health Informatics
- Published
- 2014-11
- Volume
- 18
- Issue
- 6
- Pages
- 1788-1795
- ISSN
- 2168-2194 (ISSN-L)
- 2168-2208
- OpenAlex
- W2016047004
- Cited by
- 90
- References
- 3
- FWCI
- 4.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.