Compressed Sensing for Bioelectric Signals: A Review
The DOI matches its Crossref record; 45 of the 45 references it cites were found in a registry or an index.
Abstract
This paper provides a comprehensive review of compressed sensing or compressive sampling (CS) in bioelectric signal compression applications. The aim is to provide a detailed analysis of the current trends in CS, focusing on the advantages and disadvantages in compressing different biosignals and its suitability for deployment in embedded hardware. Performance metrics such as percent root-mean-squared difference (PRD), signal-to-noise ratio (SNR), and power consumption are used to objectively quantify the capabilities of CS. Furthermore, CS is compared to state-of-the-art compression algorithms in compressing electrocardiogram (ECG) and electroencephalography (EEG) as examples of typical biosignals. The main technical challenges associated with CS are discussed along with the predicted future trends.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Donoho, D. L. (2006) · IEEE Transactions on Information Theory · doi:10.1109/tit.2006.871582 · Cited by 23,994
Donoho, D. L. (2004) · Cited by 16,591
Candes, E. J., Romberg, J., & Tao, T. (2006) · IEEE Transactions on Information Theory · doi:10.1109/tit.2005.862083 · Cited by 15,639 · cited 4×
“Interest in CS has grown since a number of seminal publications which demonstrate that a small number of linear projections of a sparse signal can produce a good quality reconstruction of the original signal [1]–[4].”
InfluentialAn Introduction To Compressive Sampling
Candes, E. J., & Wakin, M. B. (2008) · IEEE Signal Processing Magazine · doi:10.1109/msp.2007.914731 · Cited by 10,017 · cited 1×
“It has been shown that with using these i.i.d entries only M > C k Slog(N/S) measurements are required for accurate reconstruction (where C k is an empirical constant and S refers to the number of nonzero signal entries) [2].”
Signal Recovery From Random Measurements Via Orthogonal Matching Pursuit
Tropp, J. A., & Gilbert, A. C. (2007) · IEEE Transactions on Information Theory · doi:10.1109/tit.2007.909108 · Cited by 9,653 · cited 3×
“BP [13] L1 minimization and two greedy algorithms (matching pursuit (MP) [16] and OMP [17]) are investigated.”
Matching pursuits with time-frequency dictionaries
Mallat, S. G., & Zhang, Z. (1993) · IEEE Transactions on Signal Processing · doi:10.1109/78.258082 · Cited by 9,112 · cited 11×
“OMP's PRD values ranged from 26% to 34%.”
InfluentialAtomic Decomposition by Basis Pursuit
Chen, S. S., Donoho, D. L., & Saunders, M. A. (1998) · SIAM Journal on Scientific Computing · doi:10.1137/s1064827596304010 · Cited by 6,845 · cited 3×
“BP [13] L1 minimization and two greedy algorithms (matching pursuit (MP) [16] and OMP [17]) are investigated.”
Near-Optimal Signal Recovery From Random Projections: Universal Encoding Strategies?
Candes, E. J., & Tao, T. (2006) · IEEE Transactions on Information Theory · doi:10.1109/tit.2006.885507 · Cited by 6,839 · cited 3×
“Interest in CS has grown since a number of seminal publications which demonstrate that a small number of linear projections of a sparse signal can produce a good quality reconstruction of the original signal [1]–[4].”
A new, fast, and efficient image codec based on set partitioning in hierarchical trees
Said, A., & Pearlman, W. A. (1996) · IEEE Transactions on Circuits and Systems for Video Technology · doi:10.1109/76.499834 · Cited by 5,353 · cited 1×
“SPIHT is a state-of-the-art wavelet-based compression method originally proposed by Said and Pearlman [32].”
Single-pixel imaging via compressive sampling
Duarte, M. F., Davenport, M. A., Takhar, D., Laska, J. N., Sun, T., Kelly, K. F., & Baraniuk, R. G. (2008) · IEEE Signal Processing Magazine · doi:10.1109/msp.2007.914730 · Cited by 3,575 · cited 1×
“’s in 2008 [58], proposing single pixel imaging using CS.”
Subspace Pursuit for Compressive Sensing Signal Reconstruction
Dai, W., & Milenkovic, O. (2009) · IEEE Transactions on Information Theory · doi:10.1109/tit.2009.2016006 · Cited by 2,388
Lustig, M., Donoho, D. L., Santos, J. M., & Pauly, J. M. (2008) · IEEE Signal Processing Magazine · doi:10.1109/msp.2007.914728 · Cited by 2,246 · cited 1×
“Previous work has explored the use of CS in biomedical imaging applications such as magnetic resonance imaging (MRI) [7], [8], ultrasound [9], and computed tomography (CT) [10]; however, this review focuses on 1-”
Just relax: convex programming methods for identifying sparse signals in noise
Tropp, J. A. (2006) · IEEE Transactions on Information Theory · doi:10.1109/tit.2005.864420 · Cited by 1,407 · cited 1×
“The coherence μ between the sensing matrix and the dictionary measures the largest correlation between any two elements of Ψ and Φ, defined in (6) [11].”
Chen, M., Gonzalez, S., Vasilakos, A., Cao, H., & Leung, V. C. M. (2011) · Mobile Networks and Applications · doi:10.1007/s11036-010-0260-8 · Cited by 1,352
Beyond Nyquist: Efficient Sampling of Sparse Bandlimited Signals
Tropp, J. A., Laska, J. N., Duarte, M. F., Romberg, J. K., & Baraniuk, R. G. (2010) · IEEE Transactions on Information Theory · doi:10.1109/tit.2009.2034811 · Cited by 1,089 · cited 1×
“1) Random Demodulator Architecture: Analog CS hardware acquisition systems in the literature are generally variations of a random demodulator (RD) architecture [59]–[61].”
A Comprehensive Survey of Wireless Body Area Networks: On PHY, MAC, and Network Layers Solutions
Ullah, S., Higgins, H., Braem, B., Latre, B., Blondia, C., Moerman, I., Saleem, S., Rahman, Z., & Kwak, K. S. (2012) · Journal of Medical Systems · doi:10.1007/s10916-010-9571-3 · Cited by 811 · cited 1×
“focus on them from a research and development perspective in recent times [50]–[52].”
Compressed Sensing for Real-Time Energy-Efficient ECG Compression on Wireless Body Sensor Nodes
Mamaghanian, H., Khaled, N., Atienza, D., & Vandergheynst, P. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2156795 · Cited by 701
Compressed Sensing Signal and Data Acquisition in Wireless Sensor Networks and Internet of Things
Li, S., Xu, L. D., & Wang, X. (2013) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2012.2189222 · Cited by 561 · cited 1×
“A number of recent publications have explored the potential of CS in BANs [20], [41], [53]–[56].”
Normalized Iterative Hard Thresholding: Guaranteed Stability and Performance
Blumensath, T., & Davies, M. E. (2010) · IEEE Journal of Selected Topics in Signal Processing · doi:10.1109/jstsp.2010.2042411 · Cited by 485 · cited 1×
“The algorithms tested were BP convex optimization [13], OMP [17], CoSaMP [18], [19], regularized orthogonal least squares [44], and normalized iterative hard thresholding [45].”
Theory and Implementation of an Analog-to-Information Converter using Random Demodulation
Laska, J. N., Kirolos, S., Duarte, M. F., Ragheb, T. S., Baraniuk, R. G., & Massoud, Y. (2007) · 2007 IEEE International Symposium on Circuits and Systems (ISCAS) · doi:10.1109/iscas.2007.378360 · Cited by 412
The weighted diagnostic distortion (WDD) measure for ECG signal compression
Zigei, Y., Cohen, A., & Katz, A. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2000.880093 · Cited by 405 · cited 2×
“[47] classified different PRD ranges in terms of the”
Analog-to-Information Conversion via Random Demodulation
Kirolos, S., Laska, J., Wakin, M., Duarte, M., Baron, D., Ragheb, T., Massoud, Y., & Baraniuk, R. (2006) · 2006 IEEE Dallas/CAS Workshop on Design, Applications, Integration and Software · doi:10.1109/dcas.2006.321036 · Cited by 393 · cited 1×
“1) Random Demodulator Architecture: Analog CS hardware acquisition systems in the literature are generally variations of a random demodulator (RD) architecture [59]–[61].”
Chen, F., Chandrakasan, A. P., & Stojanovic, V. M. (2012) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2011.2179451 · Cited by 376 · cited 2×
“presented a hardware implementation of CS with a view to implementing the algorithm on wireless sensor nodes [65], [66].”
Compressed Sensing System Considerations for ECG and EMG Wireless Biosensors
Dixon, A. M. R., Allstot, E. G., Gangopadhyay, D., & Allstot, D. J. (2012) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2012.2193668 · Cited by 311 · cited 1×
“Another area which has been explored in the recent literature is CS reconstruction algorithms and their performance with ECG compression [41]–[43].”
Zhang, Z., Jung, T.-P., Makeig, S., & Rao, B. D. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2217959 · Cited by 263 · cited 1×
“There have been several publications describing dictionaries such as a Slepian basis and a Gabor frame [20], [22]–[28].”
Blind Compressive Sensing Dynamic MRI
Lingala, S. G., & Jacob, M. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2255133 · Cited by 237 · cited 1×
“Previous work has explored the use of CS in biomedical imaging applications such as magnetic resonance imaging (MRI) [7], [8], ultrasound [9], and computed tomography (CT) [10]; however, this review focuses on 1-”
Compressed Sensing Framework for EEG Compression
Aviyente, S. (2007) · 2007 IEEE/SP 14th Workshop on Statistical Signal Processing · doi:10.1109/ssp.2007.4301243 · Cited by 177 · cited 1×
“Aviyente [27] presented a CS framework for EEG compression and analyzed the mean square error (MSE) of the EEG signals based on a Gabor frame method.”
Compressed Sensing Analog Front-End for Bio-Sensor Applications
Gangopadhyay, D., Allstot, E. G., Dixon, A. M. R., Natarajan, K., Gupta, S., & Allstot, D. J. (2014) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2013.2284673 · Cited by 175 · cited 1×
“designed a low power CS analog front end sensor for the use on ECG signals [64].”
Compressed sensing based method for ECG compression
Polania, L. F., Carrillo, R. E., Blanco-Velasco, M., & Barner, K. E. (2011) · 2011 IEEE International Conference on Acoustics, Speech and Signal Processing (ICASSP) · doi:10.1109/icassp.2011.5946515 · Cited by 153
Wireless Body Area Networks for Healthcare: A Survey
V. Crosby, G. (2012) · International Journal of Ad hoc, Sensor & Ubiquitous Computing · doi:10.5121/ijasuc.2012.3301 · Cited by 151
On the Difference Between Orthogonal Matching Pursuit and Orthogonal Least Squares
Blumensath, T., & Davies, M. E. (2007) · ePrints Soton (University of Southampton) · Cited by 93
Compressive sensing scalp EEG signals: implementations and practical performance
Abdulghani, A. M., Casson, A. J., & Rodriguez–Villegas, E. (2011) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-011-0832-1 · Cited by 91 · cited 5×
“[21,26,33] Cubic B-Spline chosen as it has lowest PRD value.”
InfluentialA wavelet-packets based algorithm for EEG signal compression
Cardenas-Barrera, J. L., Lorenzo‐Ginori, J. V., & Rodríguez-Valdivia, E. (2004) · Medical Informatics and the Internet in Medicine · doi:10.1080/14639230310001636499 · Cited by 91 · cited 1×
“A small number of papers on EEG compression have explored the range of acceptable PRD levels of a reconstructed EEG signal [30], [31].”
Time-Resolved Interventional Cardiac C-arm Cone-Beam CT: An Application of the PICCS Algorithm
Chen, G., Thériault-Lauzier, P., Tang, J., Nett, B. E., Leng, S., Zambelli, J. N., Qi, Z., Bevins, N., Raval, A. N., Reeder, S. B., et al. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2011.2172951 · Cited by 82
A signal-agnostic compressed sensing acquisition system for wireless and implantable sensors
Chen, F., Chandrakasan, A. P., & Stojanovic, V. (2010) · IEEE Custom Integrated Circuits Conference 2010 · doi:10.1109/cicc.2010.5617383 · Cited by 79 · cited 2×
“presented a hardware implementation of CS with a view to implementing the algorithm on wireless sensor nodes [65], [66].”
Design and Exploration of Low-Power Analog to Information Conversion Based on Compressed Sensing
Mamaghanian, H., Khaled, N., Atienza, D., & Vandergheynst, P. (2012) · IEEE Journal on Emerging and Selected Topics in Circuits and Systems · doi:10.1109/jetcas.2012.2220253 · Cited by 71 · cited 1×
“As mentioned, CS reduces the resources required in signal acquisition [5].”
Compressed sensing of ultrasound images: Sampling of spatial and frequency domains
Quinsac, C., Basarab, A., Girault, J., & Kouamé, D. (2010) · SiPS ... design and implementation - IEEE Workshop on Signal Processing Systems · doi:10.1109/sips.2010.5624793 · Cited by 58 · cited 1×
“Previous work has explored the use of CS in biomedical imaging applications such as magnetic resonance imaging (MRI) [7], [8], ultrasound [9], and computed tomography (CT) [10]; however, this review focuses on 1-”
Compressive sensing and random filtering of EEG signals using Slepian basis
Şenay, S., Chaparro, L. F., Sun, M., & Sclabassi, R. J. (2008) · Cited by 38
PEAR: Power Efficiency through Activity Recognition (for ECG-based Sensing)
Sun, F.-T., Kuo, C., & Griss, M. (2011) · International Conference on Pervasive Computing Technologies for Healthcare · doi:10.4108/icst.pervasivehealth.2011.246037 · Cited by 37
Chae, D. H., Alem, Y. F., Durrani, S., & Kennedy, R. A. (2013) · IEEE International Conference on Acoustics Speech and Signal Processing · doi:10.1109/icassp.2013.6637862 · Cited by 34 · cited 5×
“4 4 Casson and Rodriguez-Villegas [20] BP 2.6 2.5 Chae et al. [37] BP 9 2.5 Pooyan et al. [36] SPIHT approach.”
InfluentialECG signal compression using compressed sensing with nonuniform binary matrices
Ansari-Ram, F., & Hosseini-Khayat, S. (2012) · CSI International Symposium on Artificial Intelligence and Signal Processing · doi:10.1109/aisp.2012.6313763 · Cited by 31 · cited 1×
“Ansari-Ram and Hosseini-Khayat proposed a new method for creating the sensing matrix which improves the PRD vs. CR analysis for ECG signals [46].”
Signal agnostic compressive sensing for Body Area Networks: Comparison of signal reconstructions
Casson, A. J., & Rodriguez–Villegas, E. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6346966 · Cited by 25 · cited 1×
“The feasibility of employing CS as an EEG compression technique to reduce the storage and processing load has already been investigated [20], [21].”
CapMux: A scalable analog front end for low power compressed sensing
Charbiwala, Z. M., Martin, P., & Srivastava, M. B. (2012) · International Green and Sustainable Computing Conference · doi:10.1109/igcc.2012.6322255 · Cited by 13 · cited 1×
“[62] designed a hardware architectue for CS, comprising a scalable analog low power front end.”
System considerations for the compressive sampling of EEG and ECoG bio-signals
Gangopadhyay, D., Allstot, E. G., Dixon, A. M. R., & Allstot, D. J. (2011) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2011.6107744 · Cited by 13 · cited 1×
“" However, Gangopadhyay et al. claimed that a wavelet domainbased method is more suitable for EEG CS compression than the Gabor frame method [23].”
An architecture for 1-bit localized compressive sensing with applications to EEG
Haboba, J., Mangia, M., Rovatti, R., & Setti, G. (2011) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2011.6107746 · Cited by 12
Cited by
A neural algorithm for the non-uniform and adaptive sampling of biomedical data
Mesin, L. (2016) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2016.02.004 · Cited by 22
“, ECG from a healthy subject) and it is not clear how the proposed method would cope with a highly varying heart rate or occurrence of an arrhythmia [1].”
BackgroundInfluential
Metadata
- Authors
- Craven, D., McGinley, B., Kilmartin, L., Glavin, M., & Jones, E.
- Venue
- IEEE Journal of Biomedical and Health Informatics
- Published
- 2015-03
- Volume
- 19
- Issue
- 2
- Pages
- 529-540
- ISSN
- 2168-2194 (ISSN-L)
- 2168-2208
- OpenAlex
- W1995756791
- Cited by
- 182
- References
- 45
- FWCI
- 19.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.