Toward Continuous, Noninvasive Assessment of Ventricular Function and Hemodynamics: Wearable Ballistocardiography
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Ballistocardiography, the measurement of the reaction forces of the body to cardiac ejection of blood, is one of the few techniques available for unobtrusively assessing the mechanical aspects of cardiovascular health outside clinical settings. Recently, multiple experimental studies involving healthy subjects and subjects with various cardiovascular diseases have demonstrated that the ballistocardiogram (BCG) signal can be used to trend cardiac output, contractility, and beat-by-beat ventricular function for arrhythmias. The majority of these studies has been performed with "fixed" BCG instrumentation-such as weighing scales or chairs-rather than wearable measurements. Enabling wearable, and thus continuous, recording of BCG signals would greatly expand the capabilities of the technique; however, BCG signals measured using wearable devices are morphologically dissimilar to measurements from "fixed" instruments, precluding the analysis and interpretation techniques from one domain to be applied to the other. In particular, the time intervals between the electrocardiogram (ECG) and BCG-namely, the R-J interval, a surrogate for measuring contractility changes-are significantly different for the accelerometer compared to a "fixed" BCG measurement. This paper addresses this need for quantitatively normalizing wearable BCG measurement to "fixed" measurements with a systematic experimental approach. With these methods, the same analysis and interpretation techniques developed over the past decade for "fixed" BCG measurement can be successfully translated to wearable measurements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Heidenreich, P. A., Trogdon, J. G., Khavjou, O. A., Butler, J., Dracup, K., Ezekowitz, M. D., Finkelstein, E. A., Hong, Y., Johnston, S. C., Khera, A., et al. (2011) · Circulation · doi:10.1161/cir.0b013e31820a55f5 · Cited by 3,208
Systolic Time Intervals in Heart Failure in Man
WEISSLER, A. M., HARRIS, W. S., & SCHOENFELD, C. D. (1968) · Circulation · doi:10.1161/01.cir.37.2.149 · Cited by 1,217 · cited 1×
“indication of problems in cardiac performance [29].”
Systematic Review of Home Telemonitoring for Chronic Diseases: The Evidence Base
Pare, G., Jaana, M., & Sicotte, C. (2007) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m2270 · Cited by 816
Di Rienzo, M., Vaini, E., Castiglioni, P., Merati, G., Meriggi, P., Parati, G., Faini, A., & Rizzo, F. (2013) · Autonomic Neuroscience · doi:10.1016/j.autneu.2013.04.005 · Cited by 163
Pandia, K., Inan, O. T., Kovacs, G. T. A., & Giovangrandi, L. (2012) · Physiological Measurement · doi:10.1088/0967-3334/33/10/1643 · Cited by 114 · cited 1×
“was several times lower: the LIS344ALH (ST Microelectronics, Geneva, Switzerland) accelerometer used in previous studies [24], [34] represents the lowest noise MEMS accelerometer available, with a self-noise of 350 μgrms for a bandwidth of 1–50 Hz compared to the 60 μgrms for the 356A32 used here.”
MethodSelf-citation
Cited by
Emotion recognition using wireless signals
Zhao, M., Adib, F., & Katabi, D. (2016) · Proceedings of the 22nd Annual International Conference on Mobile Computing and Networking · doi:10.1145/2973750.2973762 · Cited by 461
In-Ear Audio Wearable: Measurement of Heart and Breathing Rates for Health and Safety Monitoring
Martin, A., & Voix, J. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2720463 · Cited by 112
“The pressure variation measured in the earcanal due to heartbeats can be caused by the combination of several effects: 1) the blood vessels around the earcanal expand due to the pulse wave [4], [10], 2) the indirect bone and tissue conduction of the heartbeat sound from the heart to the occluded earcanal (occlusion ef…”
BackgroundEtemadi, M., Inan, O. T., Heller, J. A., Hersek, S., Klein, L., & Roy, S. (2016) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2015.2405480 · Cited by 95
Self-citation
Metadata
- Authors
- Wiens, A. D., Etemadi, M., Roy, S., Klein, L., & Inan, O. T.
- Venue
- IEEE Journal of Biomedical and Health Informatics
- Published
- 2015-07
- Volume
- 19
- Issue
- 4
- Pages
- 1435-1442
- ISSN
- 2168-2194 (ISSN-L)
- 2168-2208
- OpenAlex
- W1986463353
- Cited by
- 69
- References
- 6
- FWCI
- 4.80
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Toward Continuous, Noninvasive Assessment of Ventricular Function and Hemodynamics: Wearable Ballistocardiography. https://app.cochat.ai/papers/10.1109/jbhi.2014.2359937
- The paper
- Wiens, A. D., Etemadi, M., Roy, S., Klein, L., & Inan, O. T. (2015). Toward Continuous, Noninvasive Assessment of Ventricular Function and Hemodynamics: Wearable Ballistocardiography. IEEE Journal of Biomedical and Health Informatics. https://doi.org/10.1109/jbhi.2014.2359937
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.