Automated ECG Noise Detection and Classification System for Unsupervised Healthcare Monitoring
The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Automatic detection and classification of noises can play a vital role in the development of robust unsupervised electrocardiogram (ECG) analysis systems. This paper proposes a novel unified framework for automatic detection, localization, and classification of single and combined ECG noises. METHODS: The proposed framework consists of the modified ensemble empirical mode decomposition (CEEMD), the short-term temporal feature extraction, and the decision-rule-based noise detection and classification. In the proposed framework, ECG signals are first decomposed using the modified CEEMD algorithm for discriminating the ECG components from the noises and artifacts. Then, the short-term temporal features such as maximum absolute amplitude, number of zerocrossings, and local maximum peak amplitude of the autocorelation function are computed from the extracted high-frequency and low-frequency signals. Finally, a decision rule-based algorithm is presented for detecting the presence of noises and classifying the processed ECG signals into six signal groups: noise-free ECG, ECG+BW, ECG+MA, ECG+PLI, ECG+BW+PLI, and ECG+BW+MA. RESULTS: The proposed framework is rigorously evaluated on five benchmark ECG databases and the real-time ECG signals. The proposed framework achieves an average sensitivity of 99.12%, specificity of 98.56%, and overall accuracy of 98.90% in detecting the presence of noises. Classification results show that the framework achieves an average sensitivity, positive predictivity, and classification accuracy of 98.93%, 98.39%, and 97.38%, respectively. CONCLUSION: The proposed framework not only achieves better noise detection and classification rates than the current state-of-the-art methods but also accurately localizes short bursts of noises with low endpoint delineation errors. SIGNIFICANCE: Extensive studies on benchmark databases demonstrate that the proposed framework is more suitable for reducing false alarm rates and selecting appropriate noise-specific denoising techniques in automated ECG analysis applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ENSEMBLE EMPIRICAL MODE DECOMPOSITION: A NOISE-ASSISTED DATA ANALYSIS METHOD
WU, Z., & HUANG, N. E. (2009) · Advances in Adaptive Data Analysis · doi:10.1142/s1793536909000047 · Cited by 8,715 · cited 1×
“Empirical mode decomposition (EMD), which is a self-adaptive time-frequency analysis technique, is widely used for decomposing complex, multicomponent signal into several fast and slow oscillations called intrinsic mode functions (IMFs) [29].”
MethodThe impact of the MIT-BIH Arrhythmia Database
Moody, G. B., & Mark, R. G. (2001) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.932724 · Cited by 4,812 · cited 2×
“The MIT-BIHA database contains 15 different types of heartbeats, good quality of ECG signals, signal loss, and different kinds of noises such as baseline wanders and muscle artifacts [32].”
MethodA complete ensemble empirical mode decomposition with adaptive noise
Torres, M. E., Colominas, M. A., Schlotthauer, G., & Flandrin, P. (2011) · 2011 IEEE International Conference on Acoustics, Speech and Signal Processing (ICASSP) · doi:10.1109/icassp.2011.5947265 · Cited by 2,801 · cited 2×
“proposed the CEEMD algorithm that adds different realizations of Gaussian noise to the residual signal after extracting subsequent intrinsic mode functions [30].”
MethodA dynamical model for generating synthetic electrocardiogram signals
McSharry, P. E., Clifford, G. D., Tarassenko, L., & Smith, L. A. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.808805 · Cited by 1,224 · cited 1×
“For performance evaluation, different kinds of noisy ECG signals having time-varying noise levels and composite noise sources are generated using realistic ECG noises such as the baseline wander, muscle artifacts, and electrode movements [37].”
BackgroundA comparison of the noise sensitivity of nine QRS detection algorithms
Friesen, G. M., Jannett, T. C., Jadallah, M. A., Yates, S. L., Quint, S. R., & Nagle, H. T. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.43620 · Cited by 1,043 · cited 3×
“The ECG noises and artifacts are typically characterized by their peak-to-peak amplitude, frequency content and duration [1].”
BackgroundAge-related alterations in the fractal scaling of cardiac interbeat interval dynamics
Iyengar, N., Peng, C. K., Morin, R., Goldberger, A. L., & Lipsitz, L. A. (1996) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.1996.271.4.r1078 · Cited by 702 · cited 1×
“In this study, we evaluate performance of the proposed framework using different kinds of noise-free and noisy ECG signals taken from a wide variety of benchmark ECG databases, including the MIT-BIH Arrhythmia (MIT-BIHA) database [32], the MIT-BIH ST Change (MIT-BIHSTC) database [33], the PTB Diagnostic ECG (PTBDECG)…”
MethodNutzung der EKG-Signaldatenbank CARDIODAT der PTB über das Internet
Bousseljot, R., Kreiseler, D., & Schnabel, A. (2009) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmte.1995.40.s1.317 · Cited by 623 · cited 2×
“The signals were digitized at 1000 samples per second with 16 bit resolution [34].”
MethodLi, Q., Mark, R. G., & Clifford, G. D. (2008) · Physiological Measurement · doi:10.1088/0967-3334/29/1/002 · Cited by 426
Rangayyan, R. M. (2001) · Institute of Electrical and Electronics Engineers eBooks · doi:10.1109/9780470544204 · Cited by 422
A novel method for detecting R-peaks in electrocardiogram (ECG) signal
Manikandan, M. S., & Soman, K. P. (2012) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2011.03.004 · Cited by 393 · cited 1×
“Literature studies show that existing QRS detectors had high false negative rates even for noise-free ECG signals including wide-QRS and low-QRS complexes, sudden changes in QRS morphology, tall peaked T waves and irregular RR intervals [28].”
BackgroundSelf-citation
Cited by
ECG Monitoring Systems: Review, Architecture, Processes, and Key Challenges
Serhani, M. A., T. El Kassabi, H., Ismail, H., & Nujum Navaz, A. (2020) · Sensors · doi:10.3390/s20061796 · Cited by 357
A Review of Signal Processing Techniques for Electrocardiogram Signal Quality Assessment
Satija, U., Ramkumar, B., & Manikandan, M. S. (2018) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2018.2810957 · Cited by 295
“[82], ECGdenoising [16], [12], and the ECGnoise detection and classification [6], [7], [83]–[86]), we highlight key challenging practical issues of existing SQA methods.”
BackgroundSelf-citationSevakula, R. K., Au‐Yeung, W. M., Singh, J. P., Heist, E. K., Isselbacher, E. M., & Armoundas, A. A. (2020) · Journal of the American Heart Association · doi:10.1161/jaha.119.013924 · Cited by 173
Satija, U., Ramkumar, B., & Manikandan, M. S. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2877055 · Cited by 102
Self-citation
Metadata
- Authors
- Satija, U., Ramkumar, B., & Manikandan, M. S.
- Venue
- IEEE Journal of Biomedical and Health Informatics
- Published
- 2018-05
- Volume
- 22
- Issue
- 3
- Pages
- 722-732
- ISSN
- 2168-2194 (ISSN-L)
- 2168-2208
- OpenAlex
- W2597701414
- Cited by
- 180
- References
- 35
- FWCI
- 8.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.