A Supervised Approach to Robust Photoplethysmography Quality Assessment
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Early detection of Atrial Fibrillation (AFib) is crucial to prevent stroke recurrence. New tools for monitoring cardiac rhythm are important for risk stratification and stroke prevention. As many of new approaches to long-term AFib detection are now based on photoplethysmogram (PPG) recordings from wearable devices, ensuring high PPG signal-to-noise ratios is a fundamental requirement for a robust detection of AFib episodes. Traditionally, signal quality assessment is often based on the evaluation of similarity between pulses to derive signal quality indices. There are limitations to using this approach for accurate assessment of PPG quality in the presence of arrhythmia, as in the case of AFib, mainly due to substantial changes in pulse morphology. In this paper, we first tested the performance of algorithms selected from a body of studies on PPG quality assessment using a dataset of PPG recordings from patients with AFib. We then propose machine learning approaches for PPG quality assessment in 30-s segments of PPG recording from 13 stroke patients admitted to the University of California San Francisco (UCSF) neuro intensive care unit and another dataset of 3764 patients from one of the five UCSF general intensive care units. We used data acquired from two systems, fingertip PPG (fPPG) from a bedside monitor system, and radial PPG (rPPG) measured using a wearable commercial wristband. We compared various supervised machine learning techniques including k-nearest neighbors, decisions trees, and a two-class support vector machine (SVM). SVM provided the best performance. fPPG signals were used to build the model and achieved 0.9477 accuracy when tested on the data from the fPPG exclusive to the test set, and 0.9589 accuracy when tested on the rPPG data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Practical Bayesian Optimization of Machine Learning Algorithms
Snoek, J., Larochelle, H., & Adams, R. P. (2012) · arXiv · doi:10.48550/arxiv.1206.2944 · Cited by 6,691
2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS
Kirchhof, P., Benussi, S., Kotecha, D., Ahlsson, A., Atar, D., Casadei, B., Castella, M., Diener, H.-C., Heidbuchel, H., Hendriks, J., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehw210 · Cited by 6,418
Atrial Fibrillation and Mechanisms of Stroke: Time for a New Model
Kamel, H., Okin, P. M., Elkind, M. S. V., & Iadecola, C. (2016) · Stroke · doi:10.1161/strokeaha.115.012004 · Cited by 627
Drew, B. J., Harris, P., Zègre-Hemsey, J. K., Mammone, T., Schindler, D., Salas-Boni, R., Bai, Y., Tinoco, A., Ding, Q., & Hu, X. (2014) · PLoS ONE · doi:10.1371/journal.pone.0110274 · Cited by 438 · cited 1×
“of the five general intensive care units between March 2013 and December 2016 as described in a previous study [22].”
MethodSelf-citationOrphanidou, C., Bonnici, T., Charlton, P., Clifton, D., Vallance, D., & Tarassenko, L. (2014) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2338351 · Cited by 368
Dynamic time warping and machine learning for signal quality assessment of pulsatile signals
Li, Q., & Clifford, G. D. (2012) · Physiological Measurement · doi:10.1088/0967-3334/33/9/1491 · Cited by 274 · cited 2×
“Asgari’s method [12]); Method 4 (based on G Clifford’s method [13]); Method 5 (based on C.”
BackgroundMethodPhotoplethysmogram signal quality estimation using repeated Gaussian filters and cross-correlation
Karlen, W., Kobayashi, K., Ansermino, J. M., & Dumont, G. A. (2012) · Physiological Measurement · doi:10.1088/0967-3334/33/10/1617 · Cited by 123
Chong, J. W., Dao, D. K., Salehizadeh, S. M. A., McManus, D. D., Darling, C. E., Chon, K. H., & Mendelson, Y. (2014) · Annals of Biomedical Engineering · doi:10.1007/s10439-014-1080-y · Cited by 79
Couceiro, R., Carvalho, P., Paiva, R. P., Henriques, J., & Muehlsteff, J. (2012) · 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/embc.2012.6346497 · Cited by 33
Cited by
Photoplethysmography based atrial fibrillation detection: a review
Pereira, T., Tran, N., Gadhoumi, K., Pelter, M. M., Do, D. H., Lee, R. J., Colorado, R., Meisel, K., & Hu, X. (2020) · npj Digital Medicine · doi:10.1038/s41746-019-0207-9 · Cited by 300
Self-citationPhotoplethysmography signal processing and synthesis
Mejía-Mejía, E., Allen, J., Budidha, K., El-Hajj, C., Kyriacou, P. A., & Charlton, P. H. (2022) · Photoplethysmography · doi:10.1016/b978-0-12-823374-0.00015-3 · Cited by 138
“Machine learning has also been used to develop signal quality assessment algorithms [55], [59], [60], [169], [186], [187].”
MethodPhotoplethysmogram Signal Quality Evaluation by Unsupervised Learning Approach
Roy, M. S., Gupta, R., & Sharma, K. D. (2020) · 2020 IEEE Applied Signal Processing Conference (ASPCON) · doi:10.1109/aspcon49795.2020.9276733 · Cited by 24
“Pereira [13] Binary Supervised learning 84.”
Method
Metadata
- Authors
- Pereira, T., Gadhoumi, K., Ma, M., Liu, X., Xiao, R., Colorado, R. A., Keenan, K. J., Meisel, K., & Hu, X.
- Venue
- IEEE Journal of Biomedical and Health Informatics
- Published
- 2020-03
- Volume
- 24
- Issue
- 3
- Pages
- 649-657
- ISSN
- 2168-2194 (ISSN-L)
- 2168-2208
- OpenAlex
- W2931807421
- Cited by
- 79
- References
- 9
- FWCI
- 2.82
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Supervised Approach to Robust Photoplethysmography Quality Assessment. https://app.cochat.ai/papers/10.1109/jbhi.2019.2909065
- The paper
- Pereira, T., Gadhoumi, K., Ma, M., Liu, X., Xiao, R., Colorado, R. A., Keenan, K. J., Meisel, K., & Hu, X. (2020). A Supervised Approach to Robust Photoplethysmography Quality Assessment. IEEE Journal of Biomedical and Health Informatics. https://doi.org/10.1109/jbhi.2019.2909065
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.