CoChat

PulseGAN: Learning to Generate Realistic Pulse Waveforms in Remote Photoplethysmography

Open access
Song, Rencheng, Chen, Huan, Cheng, Juan, Li, Chang, Liu, Yu, Chen, Xun · 2021 · IEEE Journal of Biomedical and Health Informatics
Cited by 248

The DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.

Abstract

Remote photoplethysmography (rPPG) is a non-contact technique for measuring cardiac signals from facial videos. High-quality rPPG pulse signals are urgently demanded in many fields, such as health monitoring and emotion recognition. However, most of the existing rPPG methods can only be used to get average heart rate (HR) values due to the limitation of inaccurate pulse signals. In this paper, a new framework based on generative adversarial network, called PulseGAN, is introduced to generate realistic rPPG pulse signals through denoising the chrominance (CHROM) signals. Considering that the cardiac signal is quasi-periodic and has apparent time-frequency characteristics, the error losses defined in time and spectrum domains are both employed with the adversarial loss to enforce the model generating accurate pulse waveforms as its reference. The proposed framework is tested on three public databases. The results show that the PulseGAN framework can effectively improve the waveform quality, thereby enhancing the accuracy of HR, the interbeat interval (IBI) and the related heart rate variability (HRV) features. The proposed method significantly improves the quality of waveforms compared to the input CHROM signals, with the mean absolute error of AVNN (the average of all normal-to-normal intervals) reduced by 41.19%, 40.45%, 41.63%, and the mean absolute error of SDNN (the standard deviation of all NN intervals) reduced by 37.53%, 44.29%, 58.41%, in the cross-database test on the UBFC-RPPG, PURE, and MAHNOB-HCI databases, respectively. This framework can be easily integrated with other existing rPPG methods to further improve the quality of waveforms, thereby obtaining more reliable IBI features and extending the application scope of rPPG techniques.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/jbhi.2021.3051176

Cites

43 of 43 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 43 references

Cited by

See all 248

Metadata

Authors
Song, R., Chen, H., Cheng, J., Li, C., Liu, Y., & Chen, X.
Venue
IEEE Journal of Biomedical and Health Informatics
Published
2021-05
Volume
25
Issue
5
Pages
1373-1384
ISSN
  • 2168-2194 (ISSN-L)
  • 2168-2208
OpenAlex
W3120068059
Cited by
248
References
43
FWCI
10.92
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: PulseGAN: Learning to Generate Realistic Pulse Waveforms in Remote Photoplethysmography. https://app.cochat.ai/papers/10.1109/jbhi.2021.3051176
The paper
Song, R., Chen, H., Cheng, J., Li, C., Liu, Y., & Chen, X. (2021). PulseGAN: Learning to Generate Realistic Pulse Waveforms in Remote Photoplethysmography. IEEE Journal of Biomedical and Health Informatics. https://doi.org/10.1109/jbhi.2021.3051176

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.