PulseGAN: Learning to Generate Realistic Pulse Waveforms in Remote Photoplethysmography
Open accessThe DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Abstract
Remote photoplethysmography (rPPG) is a non-contact technique for measuring cardiac signals from facial videos. High-quality rPPG pulse signals are urgently demanded in many fields, such as health monitoring and emotion recognition. However, most of the existing rPPG methods can only be used to get average heart rate (HR) values due to the limitation of inaccurate pulse signals. In this paper, a new framework based on generative adversarial network, called PulseGAN, is introduced to generate realistic rPPG pulse signals through denoising the chrominance (CHROM) signals. Considering that the cardiac signal is quasi-periodic and has apparent time-frequency characteristics, the error losses defined in time and spectrum domains are both employed with the adversarial loss to enforce the model generating accurate pulse waveforms as its reference. The proposed framework is tested on three public databases. The results show that the PulseGAN framework can effectively improve the waveform quality, thereby enhancing the accuracy of HR, the interbeat interval (IBI) and the related heart rate variability (HRV) features. The proposed method significantly improves the quality of waveforms compared to the input CHROM signals, with the mean absolute error of AVNN (the average of all normal-to-normal intervals) reduced by 41.19%, 40.45%, 41.63%, and the mean absolute error of SDNN (the standard deviation of all NN intervals) reduced by 37.53%, 44.29%, 58.41%, in the cross-database test on the UBFC-RPPG, PURE, and MAHNOB-HCI databases, respectively. This framework can be easily integrated with other existing rPPG methods to further improve the quality of waveforms, thereby obtaining more reliable IBI features and extending the application scope of rPPG techniques.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Labaca-Castro, R. (2023) · Machine Learning under Malware Attack · doi:10.1007/978-3-658-40442-0_9 · Cited by 19,272
GAN(Generative Adversarial Nets)
(2017) · Journal of Japan Society for Fuzzy Theory and Intelligent Informatics · doi:10.3156/jsoft.29.5_177_2 · Cited by 19,270
Heart Rate Variability: Standards of Measurement, Physiological Interpretation, and Clinical Use
Electrophysiology, T. F. O. T. E. S. O. C. T. N. A. (1996) · Circulation · doi:10.1161/01.cir.93.5.1043 · Cited by 17,159
Conditional Generative Adversarial Nets
Mirza, M., & Osindero, S. (2014) · arXiv · doi:10.48550/arxiv.1411.1784 · Cited by 8,863 · cited 2×
“In this paper, we propose a new framework, named as PulseGAN, to extract rPPG pulse signal with a conditional GAN (cGAN) [17].”
Method“Least squares generative adversarial networks,”
Mao, X., Li, Q., Xie, H., Lau, R. Y. K., Wang, Z., & Smolley, S. P. (2017) · 2017 IEEE International Conference on Computer Vision (ICCV) · doi:10.1109/iccv.2017.304 · Cited by 5,437 · cited 3×
“The loss function of discriminator remains the same as the LSGAN.”
BackgroundInfluentialRemote plethysmographic imaging using ambient light
Verkruysse, W., Svaasand, L. O., & Nelson, J. S. (2008) · Optics Express · doi:10.1364/oe.16.021434 · Cited by 1,719 · cited 6×
“[2] first verified the validity of rPPG for HR estimation from facial videos.”
BackgroundMethodInfluentialA Multimodal Database for Affect Recognition and Implicit Tagging
Soleymani, M., Lichtenauer, J., Pun, T., & Pantic, M. (2012) · IEEE Transactions on Affective Computing · doi:10.1109/t-affc.2011.25 · Cited by 1,664 · cited 13×
“To simplify the analysis, we only conduct ablation study with input testing data satisfying SNR > 0 dB in the MAHNOB-HCI database.”
MethodInfluentialNon-contact, automated cardiac pulse measurements using video imaging and blind source separation
Poh, M.-Z., McDuff, D. J., & Picard, R. W. (2010) · Optics Express · doi:10.1364/oe.18.010762 · Cited by 1,643
Advancements in Noncontact, Multiparameter Physiological Measurements Using a Webcam
Poh, M.-Z., McDuff, D. J., & Picard, R. W. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2086456 · Cited by 1,486 · cited 1×
“For example, the average HR can be calculated from IBI as [35]”
Robust pulse rate from chrominance-based rPPG
de Haan, G., & Jeanne, V. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2266196 · Cited by 1,378 · cited 6×
“For example, blind source separation (BSS) [5] based methods are proposed under some specific statistical assumption, while the model-based rPPG methods [6], [7] are derived from a skin optical reflection model.”
BackgroundMethodInfluentialFacial Landmark Detection by Deep Multi-task Learning
Zhang, Z., Luo, P., Loy, C. C., & Tang, X. (2014) · Lecture Notes in Computer Science · doi:10.1007/978-3-319-10599-4_7 · Cited by 1,365 · cited 1×
“facial landmarks [28] are detected and a region of interest (ROI) is defined according to those landmarks covering the left and right cheeks.”
BackgroundSEGAN: Speech Enhancement Generative Adversarial Network
Pascual, S., Bonafonte, A., & Serrà, J. (2017) · Interspeech 2017 · doi:10.21437/interspeech.2017-1428 · Cited by 1,297 · cited 5×
“[14] S. Pascual, A. Bonafonte, and J. Serrá, “SEGAN: Speech enhancement generative adversarial network,” in Proc.”
MethodInfluentialAlgorithmic principles of remote PPG
Wang, W., den Brinker, A. C., Stuijk, S., & de Haan, G. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2609282 · Cited by 1,234 · cited 6×
“For example, blind source separation (BSS) [5] based methods are proposed under some specific statistical assumption, while the model-based rPPG methods [6], [7] are derived from a skin optical reflection model.”
BackgroundMethodInfluentialMalik, M. (1996) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.1996.tb00275.x · Cited by 850
DeepPhys: Video-Based Physiological Measurement Using Convolutional Attention Networks
Chen, W., & McDuff, D. (2018) · Lecture Notes in Computer Science · doi:10.1007/978-3-030-01216-8_22 · Cited by 716
Unsupervised skin tissue segmentation for remote photoplethysmography
Bobbia, S., Macwan, R., Benezeth, Y., Mansouri, A., & Dubois, J. (2019) · Pattern Recognition Letters · doi:10.1016/j.patrec.2017.10.017 · Cited by 615 · cited 2×
“The UBFC-RPPG database [30] includes 42 videos under a realistic situation.”
MethodPhotoplethysmography Revisited: From Contact to Noncontact, From Point to Imaging
Sun, Y., & Thakor, N. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2476337 · Cited by 556 · cited 1×
“Both of them rely on specific sensors to contact with skins of subjects, which may be uncomfortable or unsuitable for people with sensitive skins [1].”
BackgroundNon-contact video-based pulse rate measurement on a mobile service robot
Stricker, R., Muller, S., & Gross, H.-M. (2014) · The 23rd IEEE International Symposium on Robot and Human Interactive Communication · doi:10.1109/roman.2014.6926392 · Cited by 456 · cited 17×
“The in-house BSIPL-RPPG and UBFC-RPPG databases are taken as the training set to test the PURE database.”
BackgroundMethodInfluentialRhythmNet: End-to-End Heart Rate Estimation From Face via Spatial-Temporal Representation
Niu, X., Shan, S., Han, H., & Chen, X. (2020) · IEEE Transactions on Image Processing · doi:10.1109/tip.2019.2947204 · Cited by 420 · cited 1×
“As reported in many studies [19], [43], [44], the CHROM method does not perform well in these two databases because the videos are compressed and the acquisition scenarios are complicated.”
MethodSelf-citationYu, Z., Peng, W., Li, X., Hong, X., & Zhao, G. (2019) · 2019 IEEE/CVF International Conference on Computer Vision (ICCV) · doi:10.1109/iccv.2019.00024 · Cited by 340 · cited 1×
“[23] proposed an end-to-end deep learning”
Video-Based Heart Rate Measurement: Recent Advances and Future Prospects
Chen, X., Cheng, J., Song, R., Liu, Y., Ward, R., & Wang, Z. J. (2019) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2018.2879706 · Cited by 227 · cited 1×
“After years of development, a variety of rPPG methods have been introduced according to different assumptions and mechanisms [3].”
MethodSelf-citationVIPL-HR: A Multi-modal Database for Pulse Estimation from Less-Constrained Face Video
Niu, X., Han, H., Shan, S., & Chen, X. (2019) · Lecture Notes in Computer Science · doi:10.1007/978-3-030-20873-8_36 · Cited by 213
Self-citationVideo-Based Remote Physiological Measurement via Cross-Verified Feature Disentangling
Niu, X., Yu, Z., Han, H., Li, X., Shan, S., & Zhao, G. (2020) · Lecture Notes in Computer Science · doi:10.1007/978-3-030-58536-5_18 · Cited by 213
Meta-rPPG: Remote Heart Rate Estimation Using a Transductive Meta-learner
Lee, E., Chen, E., & Lee, C.-Y. (2020) · Lecture Notes in Computer Science · doi:10.1007/978-3-030-58583-9_24 · Cited by 181
SynRhythm: Learning a Deep Heart Rate Estimator from General to Specific
Niu, X., Han, H., Shan, S., & Chen, X. (2018) · 2018 24th International Conference on Pattern Recognition (ICPR) · doi:10.1109/icpr.2018.8546321 · Cited by 174 · cited 1×
“[21] proposed a spatiotemporal representation of HR information and designed a general-to-special transfer learning strategy to estimate HR from the representation.”
BackgroundSelf-citationAutoHR: A Strong End-to-End Baseline for Remote Heart Rate Measurement With Neural Searching
Yu, Z., Li, X., Niu, X., Shi, J., & Zhao, G. (2020) · IEEE Signal Processing Letters · doi:10.1109/lsp.2020.3007086 · Cited by 165
Song, R., Zhang, S., Li, C., Zhang, Y., Cheng, J., & Chen, X. (2020) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2020.2984168 · Cited by 160 · cited 3×
“the conventional ones as demonstrated in [12], which inspires us to extract rPPG pulse waveforms under a DL framework.”
BackgroundMethodInfluentialSelf-citationRobust Remote Heart Rate Estimation from Face Utilizing Spatial-temporal Attention
Niu, X., Zhao, X., Han, H., Das, A., Dantcheva, A., Shan, S., & Chen, X. (2019) · International Conference on Automatic Face and Gesture Recognition · doi:10.1109/fg.2019.8756554 · Cited by 131 · cited 2×
“Later, the authors also applied a channel and spatial-temporal attention mechanism to further improve the HR estimation from face videos [22].”
MethodSelf-citationSiamese-rPPG network: remote photoplethysmography signal estimation from face videos
Tsou, Y.-Y., Lee, Y.-A., Hsu, C.-T., & Chang, S. (2020) · ACM Symposium on Applied Computing · doi:10.1145/3341105.3373905 · Cited by 122 · cited 3×
“best performance among all the comparison methods except for the MAE of HR in [34].”
MethodInfluential3D Convolutional Neural Networks for Remote Pulse Rate Measurement and Mapping from Facial Video
Bousefsaf, F., Pruski, A., & Maaoui, C. (2019) · Applied Sciences · doi:10.3390/app9204364 · Cited by 119
iPhys: An Open Non-Contact Imaging-Based Physiological Measurement Toolbox
McDuff, D., & Blackford, E. B. (2019) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2019.8857012 · Cited by 90 · cited 1×
“GREEN [2], ICA [5], POS [7], and CHROM [6] have been implemented with an open source toolbox [38].”
MethodМихайлович, У. А. (2018) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/aabd09 · Cited by 82 · cited 1×
“In addition, there are some other methods to achieve heart rate extraction through signal filtering [8], [9].”
MethodAdversarial de-noising of electrocardiogram
Wang, J., Li, R., Li, R., Li, K., Zeng, H., Xie, G., & Liu, L. (2019) · Neurocomputing · doi:10.1016/j.neucom.2019.03.083 · Cited by 80 · cited 1×
“With the rapid development of GAN, it has also been applied to denoise one-dimensional signals, such as speech signals [14], [15], and ECG signals [16].”
MethodWei, B., He, X., Zhang, C., & Wu, X. (2017) · BioMedical Engineering OnLine · doi:10.1186/s12938-016-0300-0 · Cited by 58 · cited 1×
“[18] employed the second-order blind source separation to extract the target signal from six RGB channels obtained in two facial regions of interest (ROIs).”
MethodAn Accurate LSTM Based Video Heart Rate Estimation Method
Bian, M., Peng, B., Wang, W., & Dong, J. (2019) · Lecture notes in computer science · doi:10.1007/978-3-030-31726-3_35 · Cited by 32
Remote Photoplethysmography Using Nonlinear Mode Decomposition
Demirezen, H., & Erdem, Ç. E. (2018) · IEEE International Conference on Acoustics Speech and Signal Processing · doi:10.1109/icassp.2018.8462538 · Cited by 31 · cited 1×
“Method HR(bpm) HRV(ms) IBI(ms) Pulse(dB) MAE RMSE MER R AVNNmae SDNNmae IBImae SNR NMD-HR [41] 8.”
BackgroundZhao, C., Mei, P., Xu, S., Li, Y., & Feng, Y. (2019) · IEEE International Conference on Computer Vision Workshops · doi:10.1109/iccvw.2019.00204 · Cited by 29
Physiological Signal Preserving Video Compression for Remote Photoplethysmography
Zhao, C., Chen, W., Lin, C., & Wu, X. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2899102 · Cited by 28 · cited 1×
“rate (HR) values by calculating the dominate frequency of the rPPG pulses [10], [11].”
BackgroundLiu, X., Yang, X., Wang, D., & Wong, A. K. C. (2020) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2020.3021222 · Cited by 28 · cited 1×
“In addition, there are some other methods to achieve heart rate extraction through signal filtering [8], [9].”
MethodLiu, X., Yang, X., Jin, J., & Wong, A. K. C. (2020) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2020.2984881 · Cited by 17 · cited 1×
“Since the length of the IBI vectors may be different, we refer to a similar way in [37] to solve this”
MethodSlapničar, G., Dovgan, E., Cuk, P., & Luštrek, M. (2019) · IEEE International Conference on Computer Vision Workshops · doi:10.1109/iccvw.2019.00206 · Cited by 12 · cited 2×
“[26] also employed a LSTM model to enhance the rough rPPG signals obtained by the POS algorithm.”
BackgroundMethodProbabilistic Signal Quality Metric for Reduced Complexity Unsupervised Remote Photoplethysmography
Benezeth, Y., Bobbia, S., Nakamura, K., Gómez, R., & Dubois, J. (2019) · International Symposium on Medical Information and Communication Technology · doi:10.1109/ismict.2019.8744004 · Cited by 12
Speech Enhancement via Generative Adversarial LSTM Networks
Xiang, Y., & Bao, C. (2018) · International Workshop on Acoustic Signal Enhancement · doi:10.1109/iwaenc.2018.8521353 · Cited by 11
Cited by
Dual-GAN: Joint BVP and Noise Modeling for Remote Physiological Measurement
Lu, H., Han, H., & Zhou, S. K. (2021) · 2021 IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr46437.2021.01222 · Cited by 196
“HR, HRV and RF estimation on UBFC-rPPG: Following the protocol in [31], the videos of the first 30 subjects are used for training, and the videos of the remaining 12 subjects are used for testing.”
BackgroundMethodInfluentialEfficientPhys: Enabling Simple, Fast and Accurate Camera-Based Cardiac Measurement
Liu, X., Hill, B., Jiang, Z., Patel, S., & McDuff, D. (2023) · 2023 IEEE/CVF Winter Conference on Applications of Computer Vision (WACV) · doi:10.1109/wacv56688.2023.00498 · Cited by 193
Camera Measurement of Physiological Vital Signs
McDuff, D. (2023) · ACM Computing Surveys · doi:10.1145/3558518 · Cited by 159
“Pulse GAN [135] (GAN stands for Generative Adversarial Network) is one such example, in which the authors used a chromiance signal as an intermediate representation during the training process.”
BackgroundMethodPhysFlow: Skin tone transfer for remote heart rate estimation through conditional normalizing flows
Comas, J., Alomar, A., Ruiz, A., & Sukno, F. (2024) · arXiv · doi:10.48550/arxiv.2407.21519 · Cited by 4
“Some combine traditional methods with Convolutional Neural Networks (CNNs) to leverage advanced features [34, 36, 47].”
Method
Metadata
- Authors
- Song, R., Chen, H., Cheng, J., Li, C., Liu, Y., & Chen, X.
- Venue
- IEEE Journal of Biomedical and Health Informatics
- Published
- 2021-05
- Volume
- 25
- Issue
- 5
- Pages
- 1373-1384
- ISSN
- 2168-2194 (ISSN-L)
- 2168-2208
- OpenAlex
- W3120068059
- Cited by
- 248
- References
- 43
- FWCI
- 10.92
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.