A Microassembled Low-Profile Three-Dimensional Microelectrode Array for Neural Prosthesis Applications
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
This paper describes the design and micro- assembly process of a low-profile 3-D microelectrode array for mapping the functional organization of targeted areas of the central nervous system and for possible application in neural prostheses. The array consists of multiple planar complimentary metal-oxide-semiconductor stimulating probes and 3-D assembly components. Parylene-encapsulated gold beams supported by etch-stopped silicon braces allow the backends of the probes to be folded over to reduce the height of the array above the cortical surface. A process permitting parylene to be used at wafer level with bulk-silicon wet release has been reported. Spacers are used to fix the microassembled probes in position and are equipped with interlocking structures to facilitate the assembly process and increase yield. Four-probe 256-site 3-D arrays operate from plusmn5 V with an average per-channel power dissipation of 97 muW at full range stimulation with pulse widths of 100 mus at 500-Hz frequency. Thirty-two sites can be stimulated simultaneously with maximum currents of plusmn127 muA and a current resolution of plusmn1 muA. The microassembly techniques allow a variety of 3-D microstructures to be created from planar components.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
PENFIELD, W., & BOLDREY, E. (1937) · Brain · doi:10.1093/brain/60.4.389 · Cited by 4,188
Biran, R., Martin, D. C., & Tresco, P. A. (2005) · Experimental Neurology · doi:10.1016/j.expneurol.2005.04.020 · Cited by 893
Flexible polyimide-based intracortical electrode arrays with bioactive capability
Rousche, P. J., Pellinen, D. S., Pivin, D. P., Williams, J. C., Vetter, R. J., & Kipke, D. R. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.914800 · Cited by 644
An Integrated-Circuit Approach to Extracellular Microelectrodes
Wise, K. D., Angell, J. B., & Starr, A. (1970) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1970.4502738 · Cited by 544 · cited 2×
“Silicon micromachined electrodes have been under development for many years [4], [6], [9] and have been extensively characterized both electrically and mechanically for neurophysiological applications [10], [11].”
BackgroundMethodSelf-citationSilicon ribbon cables for chronically implantable microelectrode arrays
Hetke, J. F., Lund, J. L., Najafi, K., Wise, K. D., & Anderson, D. J. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.284959 · Cited by 174
Self-citationStrength characterization of silicon microprobes in neurophysiological tissues
Najafi, K., & Hetke, J. F. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.55638 · Cited by 146
Cited by
Kwon, K. Y., Sirowatka, B., Weber, A., & Li, W. (2013) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2013.2282318 · Cited by 166
Integrated wireless neural interface based on the Utah electrode array
Kim, S., Bhandari, R., Klein, M., Negi, S., Rieth, L., Tathireddy, P., Toepper, M., Oppermann, H., & Solzbacher, F. (2009) · Biomedical Microdevices · doi:10.1007/s10544-008-9251-y · Cited by 165
Seidl, K., Herwik, S., Torfs, T., Neves, H. P., Paul, O., & Ruther, P. (2011) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2011.2167661 · Cited by 68
Varying-Length Polymer Microneedle Arrays Fabricated by Droplet Backside Exposure
Kwon, K. Y., Weber, A., & Li, W. (2014) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2014.2352412 · Cited by 23
“Stacking in-plane microneedles with different lengths is another way to build a varyinglength microneedle array, but this approach requires a complex assembly process [16].”
BackgroundA low-profile three-dimensional neural probe array using a silicon lead transfer structure
Cheng, M.-Y., Je, M., Tan, K. L., Tan, E. L., Lim, R., Yao, L., Li, P., Park, W.-T., Phua, E. J. R., Gan, C. L., et al. (2013) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/23/9/095013 · Cited by 18
“For the Michigan probe array [8, 9], in order to hold Michigan probes orthogonal to the platform and support the CMOS circuitry fabricated on the backbone of probes, micromachined spacers have to be implemented during assembly.”
BackgroundMethod
Metadata
- Authors
- Yao, Y., Gulari, M. N., Wiler, J. A., & Wise, K. D.
- Venue
- Journal of Microelectromechanical Systems
- Published
- 2007-08
- Volume
- 16
- Issue
- 4
- Pages
- 977-988
- ISSN
- 1057-7157 (ISSN-L)
- OpenAlex
- W1984274296
- Cited by
- 87
- References
- 6
- FWCI
- 2.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Microassembled Low-Profile Three-Dimensional Microelectrode Array for Neural Prosthesis Applications. https://app.cochat.ai/papers/10.1109/jmems.2007.896712
- The paper
- Yao, Y., Gulari, M. N., Wiler, J. A., & Wise, K. D. (2007). A Microassembled Low-Profile Three-Dimensional Microelectrode Array for Neural Prosthesis Applications. Journal of Microelectromechanical Systems. https://doi.org/10.1109/jmems.2007.896712
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.