A low-profile three-dimensional neural probe array using a silicon lead transfer structure
Open accessAbstract
This paper presents a microassembly method for low-profile three-dimensional probe arrays for neural prosthesis and neuroscience applications. A silicon (Si) lead transfer structure, Si interposer, is employed to form electrical connections between two orthogonal planes—the two dimensional probes and the dummy application-specific integrated circuit (ASIC) chip. In order to hold the probe array and facilitate the alignment of probes during assembly, a Si platform is designed to have through-substrate slots for the insertion of probes and cavities for holding the Si interposers. The electrical interconnections between the probes and the dummy ASIC chip are formed by solder reflow, resulting in greatly improved throughput in the proposed assembly method. Moreover, since the backbone of the probe can be embedded inside the cavity of the Si platform, the profile of the probe array above the cortical surface can be controlled within 750 µm. This low-profile allows the probe array not to touch the skull after it is implanted on the brain. The impedance of the assembled probe is also measured and discussed.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Fabrication of 3D microneedle electrodes by assembling 2D probe combs or etching bulk materials is expensive and time consuming.
“Because these approaches require special equipment or platforms, microneedle structures that are fabricated either by assembling 2D probe combs or etching bulk materials are expensive and time consuming.”
From A flexible three-dimensional electrode mesh: An enabling technology for wireless brain–computer interface prostheses (2016) · cites this paper as [9]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295 · see citing works
Cortical control of a prosthetic arm for self-feeding
Velliste, M., Perel, S., Spalding, M. C., Whitford, A. S., & Schwartz, A. B. (2008) · Nature · doi:10.1038/nature06996 · Cited by 1,591 · see citing works
Drake, K. L., Wise, K. D., Farraye, J., Anderson, D. J., & BeMent, S. L. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.7273 · Cited by 364 · see citing works
A high-yield microassembly structure for three-dimensional microelectrode arrays
Bai, Q., Wise, K. D., & Anderson, D. J. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.827288 · Cited by 245 · see citing works
A 32-site neural recording probe fabricated by DRIE of SOI substrates
Peter Norlin, A., Kindlundh, M., Mouroux, A., Yoshida, K., & Hofmann, U. (2002) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/12/4/312 · Cited by 184 · see citing works
Multiple microelectrode-recording system for human intracortical applications
Ulbert, I., Halgren, E., Heit, G., & Karmos, G. (2001) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(01)00330-2 · Cited by 173 · see citing works
Integrated wireless neural interface based on the Utah electrode array
Kim, S., Bhandari, R., Klein, M., Negi, S., Rieth, L., Tathireddy, P., Toepper, M., Oppermann, H., & Solzbacher, F. (2009) · Biomedical Microdevices · doi:10.1007/s10544-008-9251-y · Cited by 165 · see citing works
A 100-Channel 1-mW Implantable Neural Recording IC
Zou, X., Liu, L., Cheong, J. H., Yao, L., Li, P., Cheng, M.-Y., Goh, W. L., Rajkumar, R., Dawe, G. S., Cheng, K.-W., et al. (2013) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2013.2249175 · Cited by 132 · see citing works
Self-citationHerwik, S., Kisban, S., Aarts, A. A. A., Seidl, K., Girardeau, G., Benchenane, K., Zugaro, M. B., Wiener, S. I., Paul, O., Neves, H. P., et al. (2009) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/19/7/074008 · Cited by 113 · see citing works
Polyimide based neural implants with stiffness improvement
Lee, K., Singh, A., He, J., Massia, S. P., Kim, B., & Raupp, G. B. (2004) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2003.10.018 · Cited by 98 · see citing works
Yao, Y., Gulari, M. N., Wiler, J. A., & Wise, K. D. (2007) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2007.896712 · Cited by 87 · see citing works
An interconnect for out-of-plane assembled biomedical probe arrays
Aarts, A. A. A., Neves, H. P., Puers, R., & Hoof, C. A. V. (2008) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/18/6/064004 · Cited by 42 · see citing works
A Three-Dimensional 64-Site Folded Electrode Array Using Planar Fabrication
Merriam, S. M. E., Srivannavit, O., Gulari, M. N., & Wise, K. D. (2011) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2011.2127450 · Cited by 41 · see citing works
Morphological Study of the Spinal Canal Content for Subarachnoid Endoscopy
Zaaroor, M., Kósa, G., Peri-Eran, A., Maharil, I., Shoham, M., & Goldsher, D. (2006) · min - Minimally Invasive Neurosurgery · doi:10.1055/s-2006-948000 · Cited by 35 · see citing works
Topper, M. J., Klein, M., Buschick, K., Glaw, V., Orth, K., Ehrmann, O., Hütter, M., Oppermann, H. H., Becker, K.-F., Braun, T., et al. (2006) · IEEE Electronic Components and Technology Conference (ECTC) · doi:10.1109/ectc.2006.1645734 · Cited by 24 · see citing works
Novel glass microprobe arrays for neural recording
Lin, C.-W., Lee, Y., Chang, C.-W., Hsu, W.-L., Chang, Y., & Fang, W. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.08.006 · Cited by 23 · see citing works
Aarts, A. A. A., Srivannavit, O., Wise, K. D., Yoon, E., Puers, R., Hoof, C. A. V., & Neves, H. P. (2011) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/21/7/074012 · Cited by 20 · see citing works
Lee, Y., Lin, C.-W., Lin, C.-M., Yeh, S.-R., Chang, Y., & Fang, W. (2009) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/20/2/025014 · Cited by 18 · see citing works
Lee, Y. H., Toh, C. C. J., Chen, A., Abdullah, Z., & Zhang, Q. (2010) · IEEE Electronics Packaging Technology Conference (EPTC) · doi:10.1109/eptc.2010.5702659 · Cited by 12 · see citing works
Wafer Level Processing of Silicon Arrays for Implantable Medical Devices
Bhandari, R., Negi, S., Rieth, L. W., Topper, M. J., Normann, R. A., & Solzbacher, F. (2007) · IEEE Electronic Components and Technology Conference (ECTC) · doi:10.1109/ectc.2007.374004 · Cited by 11 · see citing works
Gold/tin soldering of flexible silicon chips onto polymer tapes
Hungar, K., & Mokwa, W. (2008) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/18/6/064002 · Cited by 8 · see citing works
Newly developed integration method for biomedical implants using flexible polymer cable
Yu, D., Ming-Yuan, C., Lim, L. S., Paing, M., & Yu, A. (2010) · IEEE Electronics Packaging Technology Conference (EPTC) · doi:10.1109/eptc.2010.5702669 · Cited by 5 · see citing works
Self-citationIntegration of low profile neural probe array with flexible polyimide cable
Ling, T. K., Ming-Yuan, C., Giao, T. P., Park, W., & Je, M. (2011) · IEEE Electronics Packaging Technology Conference (EPTC) · doi:10.1109/eptc.2011.6184534 · Cited by 3 · see citing works
Self-citationAssembly of 3D probe array for wireless implantable neuroprobe microsystem
Yu, A., Ming-Yuan, C., Kwanling, T., Yu, D., Giao, T. P., Ramana, M. B., & Je, M. (2010) · IEEE Electronics Packaging Technology Conference (EPTC) · doi:10.1109/eptc.2010.5702732 · Cited by 2 · see citing works
Self-citationDesign and fabrication of Si-neuroprobe arrays
Murthy, B. R., Kotlanka, R., Ranganathan, N., Giao, T. P., Tay, G. K. I., Je, M., & Agarwal, A. (2010) · IEEE Electronics Packaging Technology Conference (EPTC) · doi:10.1109/eptc.2010.5702758 · Cited by 2 · see citing works
Self-citation
Flagged first, then by citations
Research works printed but not linked: 1
- Lee K, Singh A, He J P, Massia S, Kim B and Raupp G 2004 Polyimide based neural implants with stiffness improvement Sensors Actuators B 102 67-72 · DOI
Cited by
Sorted by citations
Flexible, Penetrating Brain Probes Enabled by Advances in Polymer Microfabrication
Weltman, A., Yoo, J. J., & Meng, E. F. (2016) · Micromachines · doi:10.3390/mi7100180 · Cited by 180 · see citing works
Szostak, K. M., Grand, L., & Constandinou, T. G. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00665 · Cited by 170 · see citing works
A Critical Review of Microelectrode Arrays and Strategies for Improving Neural Interfaces
Ferguson, M., Sharma, D., Ross, D., & Zhao, F. (2019) · Advanced Healthcare Materials · doi:10.1002/adhm.201900558 · Cited by 124 · see citing works
A Review: Electrode and Packaging Materials for Neurophysiology Recording Implants
Yang, W., Gong, Y. P., & Li, W. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.622923 · Cited by 107 · see citing works
Xiang, Z., Liu, J., & Lee, C. (2016) · Microsystems & Nanoengineering · doi:10.1038/micronano.2016.12 · Cited by 100 · see citing works
Recent advances in silicon-based neural microelectrodes and microsystems: a review
Fekete, Z. (2015) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2015.03.055 · Cited by 99 · see citing works
Design and manufacturing challenges of optogenetic neural interfaces: a review
Goncalves, S. B., Ribeiro, J. F., da Silva, A. F., Costa, R. M., & Correia, J. H. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa7004 · Cited by 78 · see citing works
New approaches for CMOS-based devices for large-scale neural recording
Ruther, P., & Paul, O. (2014) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2014.10.007 · Cited by 61 · see citing works
3D probe array integrated with a front-end 100-channel neural recording ASIC
Cheng, M., Yao, L., Tan, K. L., Lim, R., Li, P., & Chen, W. (2014) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/24/12/125010 · Cited by 20 · see citing works
Self-citationGong, Y. P., Liu, W., Wang, R., Brauer, M. H., Zheng, K., & Li, W. (2020) · Micromachines · doi:10.3390/mi11090810 · Cited by 8 · see citing works
Ultracompact Multielectrode Array for Neurological Monitoring
Cheng, M., Damalerio, R., Chen, W., Rajkumar, R., & Dawe, G. S. (2019) · Sensors · doi:10.3390/s19102286 · Cited by 6 · see citing works
Self-citationAn expandable 36‐channel neural recording ASIC with modular digital pixel design technique
Wang, Q., Wang, G., You, C., Zhang, X., Liu, D., Zeng, H., Xue, N., Yao, L., & Li, T. (2023) · Electronics Letters · doi:10.1049/ell2.12765 · Cited by 5 · see citing works
Self-citationDepth‐Customizable 3D Electrode Array for Recording Functional Connectivity in the Brain
Kim, M., Park, S., Lee, H., Lee, J., Chou, N., & Shin, H. (2025) · Advanced Electronic Materials · doi:10.1002/aelm.202500121 · Cited by 5 · see citing works
3D multi-functional neural probe array for mapping functional connectivities in a 3D neuron chip
Shin, H., Kim, S., Choi, N., Lee, H. J., Yoon, E.-S., & Cho, I. (2016) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/memsys.2016.7421625 · Cited by 3 · see citing works
Neuroelectronic device process development and challenge
Slaughter, G. E., Robinson, M., Tyson, J., & Zhang, C. J. (2017) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2256297 · Cited by 3 · see citing works
Wang, G., You, C., Liu, Y., Liu, D., Zeng, H., Xue, N., & Yao, L. (2024) · Journal of Micromechanics and Microengineering · doi:10.1088/1361-6439/ad6f1c · Cited by 1 · see citing works
Self-citationTan, K. L., Chen, W., Damalerio, R., Lim, R., Chungpaiboonpatana, S., & Cheng, M. (2015) · IEEE Electronics Packaging Technology Conference (EPTC) · doi:10.1109/eptc.2015.7412287 · Cited by 1 · see citing works
Self-citationDevelopment of polymeric microelectronics packaging encapsulation for harsh environment applications
Phua, E. J. R. (2018) · doi:10.32657/10356/73226 · Cited by 1 · see citing works
Self-citation
- Authors
- Cheng, M.-Y., Je, M., Tan, K. L., Tan, E. L., Lim, R., Yao, L., Li, P., Park, W.-T., Phua, E. J. R., Gan, C. L., & Yu, A.
- Affiliations
- Agency for Science, Technology and Research (SG)
- Seoul National University of Science and Technology (KR)
- Nanyang Technological University (SG)
- Corresponding author
- Cheng, Ming-Yuan
- ORCID
- Venue
- Journal of Micromechanics and Microengineering
- Publisher
- IOP Publishing
- Published
- 2013-08-06
- Volume
- 23
- Issue
- 9
- Pages
- 095013
- ISSN
- 0960-1317 (ISSN-L)
- 1361-6439
- OpenAlex
- W2143885441
- Cited by
- 18
- References
- 25
- Citations by year
- 2025: 1 · 2024: 1 · 2023: 1 · 2021: 1 · 2020: 1 · 2019: 2 · 2018: 1 · 2017: 3 · 2016: 3 · 2015: 2 · 2014: 2
- FWCI
- 1.14
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- Locations
- Journal of Micromechanics and Microengineering (publishedVersion)
- DR-NTU (Nanyang Technological University) (submittedVersion)
- Funders
- Agency for Science, Technology and Research
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced MEMS and NEMS Technologies
- Physical Sciences › Engineering › Electrical and Electronic Engineering › 3D IC and TSV technologies
- Keywords
- silicon interposer, microassembly, neural prosthesis, probe impedance, application-specific integrated circuits, neural implants
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review