Microfabricated Implantable Parylene-Based Wireless Passive Intraocular Pressure Sensors
Open accessThe DOI matches its Crossref record.
Abstract
This paper presents an implantable parylene-based wireless pressure sensor for biomedical pressure sensing applications specifically designed for continuous intraocular pressure (IOP) monitoring in glaucoma patients. It has an electricalLCtank resonant circuit formed by an integrated capacitor and an inductor coil to facilitate passive wireless sensing using an external interrogating coil connected to a readout unit. Two surface-micromachined sensor designs incorporating variable capacitor and variable capacitor/inductor resonant circuits have been implemented to realize the pressure-sensitive components. The sensor is monolithically microfabricated by exploiting parylene as a biocompatible structural material in a suitable form factor for minimally invasive intraocular implantation. Pressure responses of the microsensor have been characterized to demonstrate its high pressure sensitivity ( > 7000 ppm/mmHg) in both sensor designs, which confirms the feasibility of pressure sensing with smaller than 1 mmHg of resolution for practical biomedical applications. A six-month animal study verifies theinvivobioefficacy and biostability of the implant in the intraocular environment with no surgical or postoperative complications. Preliminaryexvivoexperimental results verify the IOP sensing feasibility of such device. This sensor will ultimately be implanted at the pars plana or on the iris of the eye to fulfill continuous, convenient, direct, and faithful IOP monitoring.[2008-0111].
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A wearable and highly sensitive pressure sensor with ultrathin gold nanowires
Gong, S., Schwalb, W., Wang, Y., Chen, Y., Tang, Y., Si, J., Shirinzadeh, B., & Cheng, W. (2014) · Nature Communications · doi:10.1038/ncomms4132 · Cited by 2,064
Yang, J. C., Mun, J., Kwon, S. Y., Park, S., Bao, Z., & Park, S. (2019) · Advanced Materials · doi:10.1002/adma.201904765 · Cited by 1,641
Graphene-based wireless bacteria detection on tooth enamel
Mannoor, M. S., Tao, H., Clayton, J. D., Sengupta, A., Kaplan, D. L., Naik, R. R., Verma, N., Omenetto, F. G., & McAlpine, M. C. (2012) · Nature Communications · doi:10.1038/ncomms1767 · Cited by 1,014
Chen, L. Y., Tee, B. C. K., Chortos, A. L., Schwartz, G., Tse, V., J. Lipomi, D., Wong, H. S. P., McConnell, M. V., & Bao, Z. (2014) · Nature Communications · doi:10.1038/ncomms6028 · Cited by 541
Microengineering Pressure Sensor Active Layers for Improved Performance
Ruth, S. R. A., Feig, V. R., Tran, H., & Bao, Z. (2020) · Advanced Functional Materials · doi:10.1002/adfm.202003491 · Cited by 538
Ruth, S. R. A., Beker, L., Tran, H., Feig, V. R., Matsuhisa, N., & Bao, Z. (2020) · Advanced Functional Materials · doi:10.1002/adfm.201903100 · Cited by 457
Materials and Designs for Wireless Epidermal Sensors of Hydration and Strain
Huang, X., Liu, Y., Cheng, H., Shin, W., Fan, J. A., Liu, Z., Lu, C., Kong, G., Chen, K., Patnaik, D., et al. (2014) · Advanced Functional Materials · doi:10.1002/adfm.201303886 · Cited by 302
Smart Sensor Systems for Wearable Electronic Devices
An, B. W., Shin, J. H., Kim, S.-Y., Kim, J., Ji, S., Park, J., Lee, Y., Jang, J., Park, Y.-G., Cho, E., et al. (2017) · Polymers · doi:10.3390/polym9080303 · Cited by 289
LC Passive Wireless Sensors Toward a Wireless Sensing Platform: Status, Prospects, and Challenges
Huang, Q.-A., Dong, L., & Wang, L.-F. (2016) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2016.2602298 · Cited by 284
Chen, P.-J., Saati, S., Varma, R., Humayun, M. S., & Tai, Y.-C. (2010) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2010.2049825 · Cited by 264
Self-citationRecent Progress of Miniature MEMS Pressure Sensors
Song, P., Ma, Z., Ma, J., Yang, L., Wei, J., Zhao, Y., Zhang, M., Yang, F., & Wang, X. (2020) · Micromachines · doi:10.3390/mi11010056 · Cited by 262
Chronically implanted pressure sensors: challenges and state of the field
Yu, L., Kim, B., & Meng, E. (2014) · Sensors · doi:10.3390/s141120620 · Cited by 200
Park, J., Kim, J., Kim, K., Kim, S.-Y., Cheong, W. H., Park, K., Song, J. H., Namgoong, G., Kim, J. J., Heo, J., et al. (2016) · Nanoscale · doi:10.1039/c6nr01468b · Cited by 185
Highly sensitive and stable flexible pressure sensors with micro-structured electrodes
Quan, Y., Wei, X., Xiao, L., Wu, T., Pang, H., Liu, T., Huang, W., Wu, S., Li, S., & Chen, Z. (2017) · Journal of Alloys and Compounds · doi:10.1016/j.jallcom.2016.12.414 · Cited by 62
Piso, D., Veiga-Crespo, P., & Vecino, E. (2012) · Journal of Biomaterials and Nanobiotechnology · doi:10.4236/jbnb.2012.322037 · Cited by 22
“They are based on LC resonant systems [9].”
Background
Metadata
- Authors
- Chen, P.-J., Rodger, D. C., Saati, S., Humayun, M. S., & Tai, Y.-C.
- Venue
- Journal of Microelectromechanical Systems
- Published
- 2008-12
- Volume
- 17
- Issue
- 6
- Pages
- 1342-1351
- ISSN
- 1057-7157 (ISSN-L)
- 1941-0158
- OpenAlex
- W2129444923
- Cited by
- 251
- References
- 0
- FWCI
- 7.47
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.