Normal and Shear Force Measurement Using a Flexible Polymer Tactile Sensor With Embedded Multiple Capacitors

Hyung-Kew Lee, Jaehoon Chung, Sun-Il Chang, Euisik Yoon · 2008 · Journal of Microelectromechanical Systems

Abstract

In this paper, we report a new flexible capacitive tactile sensor array with the capability of measuring both normal and shear force distribution using polydimethylsiloxane (PDMS) as a base material. A tactile cell consists of two thick PDMS layers with embedded electrodes, an air gap, and a pillar structure. The pillar structure is formed at the center of each tactile cell between the air gap under a large bump. There are four capacitors in a cell to decompose the contact force into normal and shear components. Four capacitors are arranged in a square form. If a normal force is applied on the bump, the PDMS layer on the pillar structure is compressed, and the air gap between the top and bottom electrodes decreases, resulting in the increase in all four capacitances. If a shear force is applied, a torque is induced around the pillar. Therefore, the capacitance of the two capacitors increases, whereas that of the other two decreases. The bump and the pillar structure play a critical role to generate a torque for shear force measurement. The sensor has been realized in an 8 x 8 array of unit sensors, and each unit sensor responds to normal and shear stresses in all three axes, respectively. Measurement of a single sensor shows that the full-scale range of detectable force is about 10 mN, which corresponds to 131 kPa in three directions. The sensitivities of a cell measured with a current setup are 2.5%/mN, 3.0%/mN, and 2.9 %/mN for the x-, y-, and z-directions, respectively. Normal and shear force images are also captured from a 4 x 4 array of the fabricated sensor. Distinctive characteristic patterns appear when a shear force is applied to the sensor.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/jmems.2008.921727

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 350

Metadata

Authors
Lee, H.-K., Chung, J., Chang, S.-I., & Yoon, E.
Venue
Journal of Microelectromechanical Systems
Published
2008-08
Volume
17
Issue
4
Pages
934-942
ISSN
  • 1057-7157 (ISSN-L)
  • 1941-0158
OpenAlex
W2103654576
Cited by
350
References
8
FWCI
5.76
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Normal and Shear Force Measurement Using a Flexible Polymer Tactile Sensor With Embedded Multiple Capacitors. https://app.cochat.ai/papers/10.1109/jmems.2008.921727
The paper
Lee, H.-K., Chung, J., Chang, S.-I., & Yoon, E. (2008). Normal and Shear Force Measurement Using a Flexible Polymer Tactile Sensor With Embedded Multiple Capacitors. Journal of Microelectromechanical Systems. https://doi.org/10.1109/jmems.2008.921727

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.