The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Hybrid Bionic Systems for the Replacement of Hand Function
Abstract
In recent years, thanks to the advancement of robotics and mechatronics, new and more effective devices for the restoration and replacement of sensory-motor function in disabled people have been developed. In all these systems, user acceptability is strictly connected to several issues such as the residual abilities of the subject, the mechatronic characteristics of the robot, and also the interface chosen to link them. It is possible to figure out different "human-interface-device" combinations [also defined as "hybrid bionic systems" (HBSs)] characterized by different properties in terms of level of hybridness, connection, and augmentation. In particular, in HBSs the interface has to be customized according to the characteristics of the robotic artefact to be controlled and to the desires and needs of the final users. In this paper, our attention has been focused on the problem of the replacement of hand function after amputation. Three HBSs characterized by different levels of complexity, dexterity, and sensorization are presented in order to show the possibility of developing acceptable and effective systems by choosing different levels of connection and hybridness (i.e., different interfaces) for different devices and applications. The following case studies are presented: 1) the use of invasive interfaces to the peripheral nervous system to control a dexterous and highly sensorized hand prosthesis; 2) the use of electromyographic signals recorded using surface electrodes to control a compliant adaptive prosthesis; and 3) the use of a foot interface to control a two-degrees-of-freedom prosthesis. The preliminary results achieved so far seem to confirm the idea that the correct choice of the proper interface while developing an HBS can increase effectiveness and usability
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845 · cited 2×
“In particular, electroneurographic (ENG) signals recorded from the PNS using different neural interfaces have been used in the past to extract useful sensory information to improve the performance of neuroprostheses [ 9 ], [16], [17].”
BackgroundMethodSelf-citationControl of Multifunctional Prosthetic Hands by Processing the Electromyographic Signal
Zecca, M., Micera, S., Carrozza, M. C., & Dario, P. (2002) · Critical Reviews? in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v30.i456.80 · Cited by 606
Self-citationDhillon, G. S., Lawrence, S. M., Hutchinson, D. T., & Horch, K. W. (2004) · The Journal of Hand Surgery · doi:10.1016/j.jhsa.2004.02.006 · Cited by 354 · cited 2×
“Recently, LIFEs have been used to elicit adequate sensory feedback to the users by stimulating the afferent nerves through the LIFEs [ 18 ], [19].”
MethodDhillon, G. S., Krüger, T. B., Sandhu, J. S., & Horch, K. W. (2005) · Journal of Neurophysiology · doi:10.1152/jn.00937.2004 · Cited by 183 · cited 3×
“Preliminary experiments on the possibility of eliciting sensory feedback by stimulating the peripheral nervous system seem to confirm the potentialities of this approach [ 19 ].”
BackgroundMethodInfluentialLago, N., Ceballos, D., J Rodrı́guez, F., Stieglitz, T., & Navarro, X. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.06.025 · Cited by 178 · cited 1×
“On the other end of the invasiveness scale, sieve electrodes could represent a very interesting solution with potentially very high selectivity though several unresolved problems with their chronic stability and the requirement to sectioned nerves limit their usability [ 11 ], and they are only applicable to severed n…”
BackgroundLawrence, S. M., Dhillon, G. S., Jensen, W., Yoshida, K., & Horch, K. W. (2004) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2004.831491 · Cited by 106 · cited 1×
“For these reasons, intraneural electrodes, electrodes that penetrate the body of the nerve either inserted longitudinally (LIFE electrodes [12]–[ 14 ]) or transversally (USEA electrodes, [15]) into the PNS have been investigated as a compromise between selectivity and invasiveness.”
BackgroundMcDonnall, D., Clark, G. A., & Normann, R. A. (2004) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2004.828425 · Cited by 98 · cited 1×
“For these reasons, intraneural electrodes, electrodes that penetrate the body of the nerve either inserted longitudinally (LIFE electrodes [12]–[14]) or transversally (USEA electrodes, [ 15 ]) into the PNS have been investigated as a compromise between selectivity and invasiveness.”
BackgroundMetallized polymer fibers as leadwires and intrafascicular microelectrodes
McNaughton, T. G., & Horch, K. W. (1996) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(96)00111-2 · Cited by 76
Micera, S., Jensen, W., Sepulveda, F., Riso, R. R., & Sinkjaer, T. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.930903 · Cited by 58 · cited 1×
“In particular, electroneurographic (ENG) signals recorded from the PNS using different neural interfaces have been used in the past to extract useful sensory information to improve the performance of neuroprostheses [9], [ 16 ], [17].”
MethodCavallaro, E., Micera, S., Dario, P., Jensen, W., & Sinkjaer, T. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.816075 · Cited by 44
Self-citation
Cited by
Hammock, M. L., Chortos, A., Tee, B. C. ‐., Tok, J. B. ‐., & Bao, Z. (2013) · Advanced Materials · doi:10.1002/adma.201302240 · Cited by 2,396
On the Shared Control of an EMG-Controlled Prosthetic Hand: Analysis of User–Prosthesis Interaction
Cipriani, C., Zaccone, F., Micera, S., & Carrozza, M. C. (2008) · IEEE Transactions on Robotics · doi:10.1109/tro.2007.910708 · Cited by 453
Self-citationControl of Hand Prostheses Using Peripheral Information
Micera, S., Carpaneto, J., & Raspopovic, S. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2085429 · Cited by 403
Self-citationDouble nerve intraneural interface implant on a human amputee for robotic hand control
Rossini, P. M., Micera, S., Benvenuto, A., Carpaneto, J., Cavallo, G., Citi, L., Cipriani, C., Denaro, L., Denaro, V., Di Pino, G., et al. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.01.001 · Cited by 396
Self-citationDesign of a cybernetic hand for perception and action
Carrozza, M. C., Cappiello, G., Micera, S., Edin, B. B., Beccai, L., & Cipriani, C. (2006) · Biological Cybernetics · doi:10.1007/s00422-006-0124-2 · Cited by 341
Self-citation
Metadata
- Authors
- Micera, S., Carrozza, M. C., Beccai, L., Vecchi, F., & Dario, P.
- Venue
- Proceedings of the IEEE
- Published
- 2006-09
- Volume
- 94
- Issue
- 9
- Pages
- 1752-1762
- ISSN
- 0018-9219 (ISSN-L)
- 1558-2256
- OpenAlex
- W1995261790
- Cited by
- 77
- References
- 10
- FWCI
- 7.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Hybrid Bionic Systems for the Replacement of Hand Function. https://app.cochat.ai/papers/10.1109/jproc.2006.881294
- The paper
- Micera, S., Carrozza, M. C., Beccai, L., Vecchi, F., & Dario, P. (2006). Hybrid Bionic Systems for the Replacement of Hand Function. Proceedings of the IEEE. https://doi.org/10.1109/jproc.2006.881294
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.