Multichannel Intraneural and Intramuscular Techniques for Multiunit Recording and Use in Active Prostheses
The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
During the last decade there has been a renewed interest in the development of advanced, active hand prosthetic devices for amputees. In contrast to passive prostheses, active devices can be controlled by the user's intention. Active prosthetic devices have been substantially improved by integrating robot technology to achieve more functionalities and lifelike movements. Despite important progress in the technological development of prosthetics, their clinical application is still limited by the quantity and quality of biological signals that can be used for understanding the user's intention, and by the relatively poor performance of the algorithms that translate the user's intention into a desired movement. In this review we describe a solution to some of these limitations, i.e., the flexible, multichannel, implantable intraneural and intramuscular electrodes to interface the body's peripheral nerves or muscles. We aim to review the historic development, the underlying technology, and the design concepts of these electrodes. Moreover, the signal processing methods applied to these recordings and their use for the control of prosthetic devices will be discussed. Although the focus is on hand prostheses, the interface approach described is general.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845 · cited 2×
“For example, the 16 degree-of-freedom (DOF) Cyberhand can provide individual finger and joint movement [15], [ 73 ].”
BackgroundAnalysis of Models for External Stimulation of Axons
Rattay, F. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325670 · Cited by 681
Kuiken, T. A., Dumanian, G. A., Lipschutz, R. D., Miller, L. A., & Stubblefield, K. A. (2004) · Prosthetics & Orthotics International · doi:10.3109/03093640409167756 · Cited by 583
A transverse intrafascicular multichannel electrode (TIME) to interface with the peripheral nerve
Boretius, T., Badia, J., Pascual-Font, A., Schuettler, M., Navarro, X., Yoshida, K., & Stieglitz, T. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.05.010 · Cited by 468 · cited 2×
“Corrugation increases the separation between sites to further increase electrode selectivity while increasing the geometric complexity of the structure to anchor the structure better within the nerve [ 4 ]–[6].”
BackgroundSelf-citationA spiral nerve cuff electrode for peripheral nerve stimulation
Naples, G. G., Mortimer, J. T., Scheiner, A., & Sweeney, J. D. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.8670 · Cited by 415
Functionally selective peripheral nerve stimulation with a flat interface nerve electrode
Tyler, D. J., & Durand, D. M. (2002) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2002.806840 · Cited by 398 · cited 1×
“The extrafascicular approaches originate their designs from the hook electrode and led to the development of the cuff electrode [40], [41], [89], [90], the epineural electrode [31], the spiral cuff electrode [72], the multicontact cuff [32]–[34], [42], the SPINE [94], and recently the flat interface nerve electrode (F…”
BackgroundDecoding the neural drive to muscles from the surface electromyogram
Farina, D., Holobar, A., Merletti, R., & Enoka, R. M. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.10.040 · Cited by 383
Self-citationSelective Stimulation of Cat Sciatic Nerve Using an Array of Varying-Length Microelectrodes
Branner, A., Stein, R. B., & Normann, R. A. (2001) · Journal of Neurophysiology · doi:10.1152/jn.2001.85.4.1585 · Cited by 359 · cited 1×
“The intrafascicular approaches originate from the needle electrode and have led to the development of the hat-pin dosal root ganglion (DRG) electrode [58], [80], the longitudinal (LIFE) [59], and the transverse intrafascicular electrode (TIME), [4], and the USEA [7]–[ 9 ], [88], [92].”
BackgroundDhillon, G. S., Lawrence, S. M., Hutchinson, D. T., & Horch, K. W. (2004) · The Journal of Hand Surgery · doi:10.1016/j.jhsa.2004.02.006 · Cited by 354 · cited 2×
“Dhillonet al.[ 21 ]–[23] implanted an advancedversion of the polyLIFE in amputee human subjects for a short term trial.”
BackgroundLong-term stimulation and recording with a penetrating microelectrode array in cat sciatic nerve
Branner, A., Stein, R. B., Fernandez, E., Aoyagi, Y., & Normann, R. A. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.820321 · Cited by 301 · cited 1×
“The intrafascicular approaches originate from the needle electrode and have led to the development of the hat-pin dosal root ganglion (DRG) electrode [58], [80], the longitudinal (LIFE) [59], and the transverse intrafascicular electrode (TIME), [4], and the USEA [7]–[9], [88], [92].”
Background
Cited by
A wireless closed-loop system for optogenetic peripheral neuromodulation
Mickle, A. D., Won, S. M., Noh, K. N., Yoon, J., Meacham, K. W., Xue, Y., McIlvried, L. A., Copits, B. A., Samineni, V. K., Crawford, K. E., et al. (2019) · Nature · doi:10.1038/s41586-018-0823-6 · Cited by 514
Control of Hand Prostheses Using Peripheral Information
Micera, S., Carpaneto, J., & Raspopovic, S. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2085429 · Cited by 403
A review for the peripheral nerve interface designer
Larson, C. E., & Meng, E. (2020) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2019.108523 · Cited by 133
Chronic interfacing with the autonomic nervous system using carbon nanotube (CNT) yarn electrodes
McCallum, G. A., Sui, X., Qiu, C., Marmerstein, J., Zheng, Y., Eggers, T. E., Hu, C., Dai, L., & Durand, D. M. (2017) · Scientific Reports · doi:10.1038/s41598-017-10639-w · Cited by 102
Selectivity and Longevity of Peripheral-Nerve and Machine Interfaces: A Review.
Ghafoor, U., Kim, S., & Hong, K.-S. (2017) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2017.00059 · Cited by 88
“Given the limited long-term data, it is significant to consider the physical conditions of the electrodes implanted in the peripheral nerves along with their capacity to provide a long-term stable interface (Yoshida et al., 2010).”
Metadata
- Authors
- Yoshida, K., Farina, D., Akay, M., & Jensen, W.
- Venue
- Proceedings of the IEEE
- Published
- 2010-03
- Volume
- 98
- Issue
- 3
- Pages
- 432-449
- ISSN
- 0018-9219 (ISSN-L)
- 1558-2256
- OpenAlex
- W1990462672
- Cited by
- 52
- References
- 33
- FWCI
- 2.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Multichannel Intraneural and Intramuscular Techniques for Multiunit Recording and Use in Active Prostheses. https://app.cochat.ai/papers/10.1109/jproc.2009.2038613
- The paper
- Yoshida, K., Farina, D., Akay, M., & Jensen, W. (2010). Multichannel Intraneural and Intramuscular Techniques for Multiunit Recording and Use in Active Prostheses. Proceedings of the IEEE. https://doi.org/10.1109/jproc.2009.2038613
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.