The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
A High Reliability Wearable Device for Elderly Fall Detection
Abstract
Falls are critical events among elderly people that requires timely rescue. In this paper, we propose a fall detection system consisting of an inertial unit that includes triaxial accelerometer, gyroscope, and magnetometer with efficient data fusion and fall detection algorithms. Starting from the raw data, the implemented orientation filter provides the correct orientation of the subject in terms of yaw, pitch, and roll angles. The system is tested according to experimental protocols, engaging volunteers who performed simulated falls, simulated falls with recovery, and activities of daily living. By placing our wearable sensor on the waist of the subject, the unit is able to achieve fall detection performance above those of similar systems proposed in literature. The results obtained through commonly adopted protocols show excellent accuracy, sensitivity and specificity, improving the results of other techniques proposed in the literature.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Falls in older people: epidemiology, risk factors and strategies for prevention
Rubenstein, L. Z. (2006) · Age and Ageing · doi:10.1093/ageing/afl084 · Cited by 3,287
Estimation of IMU and MARG orientation using a gradient descent algorithm
Madgwick, S. O. H., Harrison, A. J. L., & Vaidyanathan, R. (2011) · 2011 IEEE International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2011.5975346 · Cited by 2,068
Nonlinear Complementary Filters on the Special Orthogonal Group
Mahony, R., Hamel, T., & Pflimlin, J.-M. (2008) · IEEE Transactions on Automatic Control · doi:10.1109/tac.2008.923738 · Cited by 1,751
Karantonis, D. M., Narayanan, M. R., Mathie, M., Lovell, N. H., & Celler, B. G. (2006) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2005.856864 · Cited by 1,236
Prevention of falls and consequent injuries in elderly people
Kannus, P., Sievänen, H., Palvanen, M., Järvinen, T., & Parkkari, J. (2005) · The Lancet · doi:10.1016/s0140-6736(05)67604-0 · Cited by 1,129
The Incidence and Economic Burden of Injuries in the United States
Finkelstein, E. A., Corso, P. S., & Miller, T. R. (2006) · Oxford University Press eBooks · doi:10.1093/acprof:oso/9780195179484.001.0001 · Cited by 933
Quaternion-Based Extended Kalman Filter for Determining Orientation by Inertial and Magnetic Sensing
Sabatini, A. M. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.875664 · Cited by 887
Fall detection - Principles and Methods
Noury, N., Fleury, A., Rumeau, P., Bourke, A. K., Laighin, G. O., Rialle, V., & Lundy, J. E. (2007) · 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2007.4352627 · Cited by 615
A threshold-based fall-detection algorithm using a bi-axial gyroscope sensor
Bourke, A. K., & Lyons, G. M. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2006.12.001 · Cited by 509
An extended Kalman filter for quaternion-based orientation estimation using MARG sensors
Marins, J. L., Yun, X., Bachmann, E. R., McGhee, R. B., & Zyda, M. J. (2002) · Proceedings 2001 IEEE/RSJ International Conference on Intelligent Robots and Systems. Expanding the Societal Role of Robotics in the the Next Millennium (Cat. No.01CH37180) · doi:10.1109/iros.2001.976367 · Cited by 499
Predictors and Prognosis of Inability to Get Up After Falls Among Elderly Persons
Tinetti, M. E. (1993) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1993.03500010075035 · Cited by 489
Falls in Older People: Risk Factors and Strategies for Prevention
Lord, S. R., Sherrington, C., Menz, H. B., & Close, J. C. T. (2007) · Cambridge University Press eBooks · doi:10.1017/cbo9780511722233 · Cited by 381
How dangerous are falls in old people at home?
Wild, D., Nayak, U. S., & Isaacs, B. (1981) · BMJ · doi:10.1136/bmj.282.6260.266 · Cited by 344
Sensors-Based Wearable Systems for Monitoring of Human Movement and Falls
Shany, T., Redmond, S. J., Narayanan, M. R., & Lovell, N. H. (2012) · IEEE Sensors Journal · doi:10.1109/jsen.2011.2146246 · Cited by 285
HMM-Based Human Fall Detection and Prediction Method Using Tri-Axial Accelerometer
Tong, L., Song, Q., Ge, Y., & Liu, M. (2013) · IEEE Sensors Journal · doi:10.1109/jsen.2013.2245231 · Cited by 238
Portable preimpact fall detector with inertial sensors
Wu, G., & Xue, S. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.916282 · Cited by 227
Hwang, J. Y., Kang, J. M., Jang, Y. W., & Kim, H. C. (2005) · The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2004.1403643 · Cited by 201
A Depth-Based Fall Detection System Using a Kinect® Sensor
Gasparrini, S., Cippitelli, E., Spinsante, S., & Gambi, E. (2014) · Sensors · doi:10.3390/s140202756 · Cited by 199
Holmberg, A. H., Johnell, O., Nilsson, P. M., Nilsson, J., Berglund, G., & Åkesson, K. (2006) · Osteoporosis International · doi:10.1007/s00198-006-0137-7 · Cited by 199
Sensitivity and specificity of fall detection in people aged 40 years and over
Kangas, M., Vikman, I., Wiklander, J., Lindgren, P., Nyberg, L., & Jämsä, T. J. (2009) · Gait & Posture · doi:10.1016/j.gaitpost.2008.12.008 · Cited by 156
Age and sex influences on fall characteristics.
O’Neill, T. W., Varlow, J., Silman, A. J., REEVE, J., Reid, D. M., Todd, C. J., & Woolf, A. D. (1994) · Annals of the Rheumatic Diseases · doi:10.1136/ard.53.11.773 · Cited by 134
Lai, C., Chang, S.-Y., Chao, H., & Huang, Y. (2010) · IEEE Sensors Journal · doi:10.1109/jsen.2010.2062501 · Cited by 132
Kangas, M., Vikman, I., Nyberg, L., Korpelainen, R., Lindblom, J., & Jämsä, T. (2012) · Gait & Posture · doi:10.1016/j.gaitpost.2011.11.016 · Cited by 126
Design and implementation of MARG sensors for 3-DOF orientation measurement of rigid bodies
Bachmann, E. R., Yun, X., McKinney, D., McGhee, R. B., & Zyda, M. (2004) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2003.1241751 · Cited by 76
Comparison of Orientation Filter Algorithms for Realtime Wireless Inertial Posture Tracking
Young, A. D. (2009) · Wearable and Implantable Body Sensor Networks · doi:10.1109/bsn.2009.25 · Cited by 63
Distinguishing syncopal from non-syncopal causes of fall in older people
Brignole, M. (2006) · Age and Ageing · doi:10.1093/ageing/afl086 · Cited by 36
Older people living at home: associations between falls and health complaints in men and women
Hedman, A. R., Fonad, E., & Sandmark, H. (2013) · Journal of Clinical Nursing · doi:10.1111/jocn.12279 · Cited by 29
Cited by
Wearable Sensors for Remote Health Monitoring
Majumder, S., Mondal, T., & Deen, M. (2017) · Sensors · doi:10.3390/s17010130 · Cited by 1,375
Internet of Things for Smart Healthcare: Technologies, Challenges, and Opportunities
Baker, S. B., Xiang, W., & Atkinson, I. (2017) · IEEE Access · doi:10.1109/access.2017.2775180 · Cited by 1,130
Advanced internet of things for personalised healthcare systems: A survey
Qi, J., Yang, P., Min, G., Amft, O., Dong, F., & Xu, L. (2017) · Pervasive and Mobile Computing · doi:10.1016/j.pmcj.2017.06.018 · Cited by 406
Elderly Fall Detection Systems: A Literature Survey
Wang, X., Ellul, J., & Azzopardi, G. (2020) · Frontiers in Robotics and AI · doi:10.3389/frobt.2020.00071 · Cited by 380
Steven Eyobu, O., & Han, D. S. (2018) · Sensors · doi:10.3390/s18092892 · Cited by 259
“[23] proposed a fall detection algorithm which was implemented in a wearable device.”
Method
Metadata
- Authors
- Pierleoni, P., Belli, A., Palma, L., Pellegrini, M., Pernini, L., & Valenti, S.
- Venue
- IEEE Sensors Journal
- Published
- 2015-08
- Volume
- 15
- Issue
- 8
- Pages
- 4544-4553
- ISSN
- 1530-437X (ISSN-L)
- 1558-1748
- OpenAlex
- W2319308093
- Cited by
- 276
- References
- 27
- FWCI
- 19.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.